+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Radiation dose reduction from low-kilovoltage liver computed tomography using multidetector row computed tomography



Radiation dose reduction from low-kilovoltage liver computed tomography using multidetector row computed tomography



Radiation Protection Dosimetry 154(1): 76-80



The primary goal of this study was to ascertain the reduction in radiation dose when conducting low-kilovoltage liver computed tomography (CT) examinations using multidetector row CT (MDCT). Fifty patients under follow-up who were diagnosed with liver cancer were examined using a 16-slice MDCT scanner and volume CT dose index (CTDI(vol)) measured according to the methods of examination, which were based on a three-phase CT scan conducted in the previous year and a four-phase CT scan was done a year later. Scanning parameters were 120 kVp-140 mA s, 120 kVp-120 mA s and 80 kVp-280 mA s. The CTDI(vol) was decreased to ∼47% at 80 kVp -280 mA s. The results indicate that low-kilovoltage liver CT is a useful means of reducing radiation doses.

(PDF emailed within 0-6 h: $19.90)

Accession: 055343427

Download citation: RISBibTeXText

PMID: 22899218

DOI: 10.1093/rpd/ncs153


Related references

Partial kilovoltage cone beam computed tomography, complete kilovoltage cone beam computed tomography, and electronic portal images for breast radiation therapy: A dose-comparison study. Practical Radiation Oncology 5(5): E521-E529, 2016

Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand. Rofo 188(5): 488-493, 2017

Multidetector computed tomography chest examinations with low-kilovoltage protocols in adults: effect on image quality and radiation dose. Journal of Computer Assisted Tomography 33(3): 416-421, 2009

Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists. Plos One 11(10): E0164859, 2016

Surface radiation dose comparison of a dedicated extremity cone beam computed tomography (CBCT) device and a multidetector computed tomography (MDCT) machine in pediatric ankle and wrist phantoms. Plos One 12(6): E0178747, 2017

Radiation dose reduction in myocardial perfusion imaging single-photon emission computed tomography/computed tomography using a dose-tracking software. Nuclear Medicine Communications 39(10): 894-900, 2018

Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter. Radiation Medicine 26(3): 171-177, 2008

High-resolution computed tomography with single-slice computed tomography and 16-channel multidetector computed tomography: a comparison regarding visibility and motion artifacts. Acta Radiologica 48(9): 956-961, 2007

Low-dose coronary artery computed tomography angiogram of an infant with tetralogy of fallot using a 256-slice multidetector computed tomography scanner. Pediatric Cardiology 30(6): 824-826, 2009

Radiation dose reduction with increasing utilization of prospective gating in 64-multidetector cardiac computed tomography angiography. Journal of Cardiovascular Computed Tomography 5(4): 264-270, 2011

Comparison of Radiation Exposure Associated With Intraoperative Cone-Beam Computed Tomography and Follow-up Multidetector Computed Tomography Angiography for Evaluating Endovascular Aneurysm Repairs. Journal of Endovascular Therapy 23(4): 583-592, 2017

Effects of the Scan Range on Radiation Dose in the Computed Tomography Component of Oncology Positron Emission Tomography/Computed Tomography. Radiation Protection Dosimetry 2018, 2018

Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics 107(4): 559-565, 2009

Usefulness of high helical pitch acquisition for reduction of patient radiation dose in cardiac multidetector computed tomography. Nihon Hoshasen Gijutsu Gakkai Zasshi 65(7): 903-912, 2009

Radiation exposure and projected risks with multidetector-row computed tomography scanning: clinical strategies and technologic developments for dose reduction. Journal of Computer Assisted Tomography 28 Suppl 1: S46-S49, 2004