+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Reconstruction interlocking nails for ipsilateral femoral neck and shaft fractures: biomechanical analysis of effect of supplementary cannulated screw on intracapsular femoral neck fracture



Reconstruction interlocking nails for ipsilateral femoral neck and shaft fractures: biomechanical analysis of effect of supplementary cannulated screw on intracapsular femoral neck fracture



Clinical Biomechanics 24(8): 642-647



To stabilize the femoral head in ipsilateral femoral neck and shaft fractures, one cannulated screw was supplemented in front of the reconstruction interlocking nail (recon nail). Twenty-eight left sawbone femurs were divided into two groups. The 14 femurs in each group were osteotomized with subcapital or transcervical fractures. The shafts of all femurs were also osteotomized, and 1cm of the distal segmental cortex was excised. Next, all the fractures were treated with static recon nails to concomitantly stabilize both femoral neck and shaft fractures. Additionally, seven subcapital fractures and seven transcervical fractures were supplemented with one cannulated screw in front of the recon nails. All specimens were tested with a Material Testing System machine to investigate the relative stability during uniaxial cyclic compression. The subcapital and transcervical fractures supplemented with one cannulated screw could bear more loads than those without screw supplementation (P<0.01 and P<0.01, respectively at any testing interval). Moreover, in the case of the subcapital fractures, the single supplemented cannulated screw could reduce the displacement at 500 N by 24% (P< 0.001). On the other hand, in the case of the transcervical fractures, one supplemented cannulated screw could reduce the displacement at 500 N by 4% (P=0.003). From the biomechanical viewpoint, the subcapital fractures in combined fractures are recommended to supplement with one cannulated screw in front of the recon nails to eliminate complications associated with stabilization.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 055411668

Download citation: RISBibTeXText

PMID: 19635640

DOI: 10.1016/j.clinbiomech.2009.06.009


Related references

Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws. Journal of Orthopaedic Trauma 31(3): 131-137, 2017

Analysis of misdiagnoses for femoral shaft fracture with ipsilateral femoral neck or femoral fractures. Zhonghua Yi Xue Za Zhi 90(7): 486-488, 2010

Ipsilateral fracture of the femoral neck and shaft, treatment by reconstruction interlocking nail. Archives of Orthopaedic and Trauma Surgery 121(1-2): 71-74, 2001

Femoral Neck Fracture Fixation in the Setting of Ipsilateral Femoral Neck and Shaft Fractures. Techniques in Orthopaedics 25(3): 148-154, 2010

Ipsilateral femoral neck and shaft fractures treated with Russell-Taylor reconstruction intramedullary nails. Chang Gung Medical Journal 29(1): 79-85, 2006

Use of reconstruction nails to manage ipsilateral displaced femoral neck-shaft fractures: assessment of a new approach. Journal of Orthopaedic Surgery 10(2): 185-193, 2002

Biomechanical comparison of dynamic hip screw, proximal femoral nail, cannulated screw, and monoaxial external fixation in the treatment of basicervical femoral neck fractures. Acta Chirurgiae Orthopaedicae et Traumatologiae Cechoslovaca 82(2): 140-144, 2015

A predictive method for subsequent avascular necrosis of the femoral head (AVNFH) by observation of bleeding from the cannulated screw used for fixation of intracapsular femoral neck fractures. Journal of Orthopaedic Trauma 21(9): 670; Author Reply 670, 2007

A Predictive Method for Subsequent Avascular Necrosis of the Femoral Head (AVNFH) by Observation of Bleeding From the Cannulated Screw Used for Fixation of Intracapsular Femoral Neck Fractures. Yearbook of Orthopedics 2008: 44-45, 2008

Cephalomedullary nails in the management of ipsilateral neck and shaft fractures of the femur--one or two femoral neck screws?. Injury 40(3): 296-303, 2009

Intracapsular fractures of the femoral neck. Results of cannulated screw fixation. Journal of Bone and Joint Surgery. American Volume 76(12): 1793-1803, 1994

Using a cannulated screw as a drill guide and sleeve: a simple technique for multiple-screw fixation for intracapsular femoral neck fracture. Orthopedics 33(8):, 2010

Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study. Journal of Orthopaedic Surgery 23(1): 41-46, 2015

Ipsilateral femoral shaft and neck fractures: are cephalomedullary nails appropriate?. Journal of Surgical Orthopaedic Advances 20(2): 122-125, 2011

Intramedullary nails with cannulated screw fixation for the treatment of unstable femoral neck fractures. Journal of International Medical Research 47(2): 557-568, 2019