Short-term in vivo performance of the Cleveland clinic PediPump left ventricular assist device



Short-term in vivo performance of the Cleveland clinic PediPump left ventricular assist device



Artificial Organs 38(5): 374-382



The PediPump was implanted in six healthy lambs (mean 25.6 ± 1.4 kg) between the left ventricular apex and the descending aorta to evaluate in vivo performance for up to 30 days. Anticoagulation was achieved by continuous heparin infusion. Three animals were euthanized prematurely, two because of respiratory dysfunction and one because of deteriorating pump performance resulting from thrombus formation inside the pump. Three lambs were electively sacrificed 30 days after implantation; all had stable hemodynamics and minimal hemolysis, as indicated by low plasma free hemoglobin (2.5 ± 3.1 mg/dL). Mean 30-day pump flow was 1.8 ± 0.1 L/min at a pump speed of 12 200 ± 400 rpm. Neither activated clotting time nor activated partial thromboplastin time followed the changes in heparin dose. At necropsy, depositions were observed at the front (n = 1) and rear rotor axial positioning stops (n = 4); improved polishing techniques on the stationary stop surfaces and the addition of a hard-carbon, thin-film coating on the rotating stop of the pumps used for the last two experiments addressed the deposition seen earlier. In conclusion, the PediPump showed excellent hydraulic performance and minimal hemolysis during support for up to 30 days. Depositions observed at the axial positioning stops in earlier experiments were addressed by design and material refinements. We continue to focus on developing effective anticoagulation management in the lamb model as well as on further evaluating and demonstrating pump biocompatibility.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 055760963

Download citation: RISBibTeXText

PMID: 24118024

DOI: 10.1111/aor.12179


Related references

Initial acute in vivo performance of the Cleveland Clinic PediPump left ventricular assist device. Asaio Journal 53(6): 766-770, 2007

Use of the percutaneous left ventricular assist device in patients with severe refractory cardiogenic shock as a bridge to long-term left ventricular assist device implantation. Journal of Heart and Lung Transplantation 27(1): 106-111, 2008

Implantable continuous-flow right ventricular assist device: lessons learned in the development of a cleveland clinic device. Annals of Thoracic Surgery 93(5): 1746-1752, 2012

Effects of exercise during long-term support with a left ventricular assist device. Results of the experience with left ventricular assist device with exercise (EVADE) pilot trial. Circulation 95(10): 2401-2406, 1997

In vitro and in vivo characterization of three different modes of pump operation when using a left ventricular assist device as a right ventricular assist device. Artificial Organs 38(11): 931-939, 2014

Peripheral extracorporeal membrane oxygenation as short-term right ventricular support after HeartWare left ventricular assist device implantation. Asaio Journal 59(5): 523-525, 2014

The PediPump: a new ventricular assist device for children. Artificial Organs 29(7): 527-530, 2005

A bridge from short-term to long-term left ventricular assist device--experimental verification of a physiological controller. Artificial Organs 28(10): 927-932, 2004

Mechanical mitral prosthesis with a short-term left ventricular assist device. Asaio Journal 54(4): 439-441, 2008

Long-term support of patients receiving a left ventricular assist device for advanced heart failure: a follow-up analysis of the Registry to Evaluate the HeartWare Left Ventricular Assist System. European Journal of Cardio-Thoracic Surgery 50(5): 834-838, 2016

Left ventricular assist device implantation: short and long-term surgical complications. Journal of Heart & Lung Transplantation 19(8S): S89-S94, 2000

The pedipump: development status of a new pediatric ventricular assist device. Asaio Journal 51(5): 536-539, 2005

Chronic evaluation of the Cleveland Clinic CorAide left ventricular assist system in calves. Artificial Organs 26(6): 529-533, 2002

Clinical performance with the Levitronix Centrimag short-term ventricular assist device. Journal of Heart and Lung Transplantation 25(2): 181-186, 2006