+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Simulated and measured spectral characteristics of 137Cs reference radiation beams



Simulated and measured spectral characteristics of 137Cs reference radiation beams



Radiation Protection Dosimetry 133(2): 81-88



137Cs sources are widely used in calibrations of radiation protection dosimeters and doserate meters. In these calibrations, conversion coefficients from the air kerma to various dose equivalent quantities are needed. These conversion quantities are functions of photon energy. In this work, Monte Carlo simulations and measurements are used for quantifying the energy distributions of the photon fluence from two 137Cs sources used for calibration purposes. The results indicate that the standard set of conversion coefficients, obtained from a monoenergetic spectrum, do not sufficiently take into account the scattered radiation (most of which is scattered by the source itself): For the large (14x15.6 mm) and small (3.5x3 mm) 137Cs sources, the simulated values for the conversion coefficients H'(0.07)/Ka and H*(10)/Ka (which were nearly equal for the both quantities) showed around 1.0 and 1.5% deviations from the ISO standard value 1.20 (for the large and small sources, respectively). Similarly, the conversion coefficient Hp(10)/Ka showed around 1.5 and 2.5% deviations from the ISO standard value 1.21 for the large and small 137Cs sources, respectively, whereas Hp(0.07)/Ka had the values 1.22 and 1.23. The amplitude of the variation of the conversion coefficients due to varying 137Cs source size did not exceed 1%. Thus, the overall uncertainty (with coverage factor k=2) due to varying source size for the average values of the conversion coefficients can be estimated as low as 0.6%.

(PDF emailed within 0-6 h: $19.90)

Accession: 055783086

Download citation: RISBibTeXText

PMID: 19251727

DOI: 10.1093/rpd/ncp021


Related references

A theoretical approach to the radiation dose-rate distribution from combined x- or y-ray beams with special reference to wedge-filtered beams. Physics in Medicine and Biology 4: 10-25, 1959

Spectral reconstruction of clinical megavoltage photon beams and the implications of spectral determination on the dosimetry of such beams. Physics in Medicine and Biology 43(6): 1507-1521, 1998

A comparison of Monte-Carlo simulated and measured dose distributions in oblique electron beams. Zeitschrift für Medizinische Physik 20(1): 17-24, 2010

The radiation field characteristics of a 137Cs source used for calibration of radiation protection instruments. Applied Radiation and Isotopes 61(6): 1425-1430, 2004

Secondary charged particle equilibrium in 137Cs and 60Co reference radiation fields. Radiation Protection Dosimetry 136(3): 168-175, 2009

Characteristics of the program for radiation dose calculation in the area of irregular entry fields of cobalt radiation beams. Nowotwory 30(4): 403-412, 1981

Reference evapotranspiration prediction using simulated and measured climate. Evapotranspiration and irrigation scheduling Proceedings of the International Conference, San Antonio, Texas, USA, November 3-6-1996: 874-879, 1996

Study of the radiation field characteristics of a 137Cs irradiator by Monte Carlo simulation. Health Physics 85(4): 433-437, 2003

Ionization chamber-based reference dosimetry of intensity modulated radiation beams. Medical Physics 31(9): 2454-2465, 2004

Radiation doses from low energy X-ray beams measured with synthetic diamond compared with calculated values obtained from the PENELOPE Monte Carlo code. Applied Radiation and Isotopes 65(8): 952-958, 2007

Radiation characteristics of narrow photon beams. Meditsinskaia Radiologiia 33(2): 50-53, 1988

Measured radial distributions of dose and linear energy transfer for alpha beams and proton beams in hydrogen and tissue equivalent gas. Radiation Research: 1-19, 1976

Simulated and measured dose response characteristics of detectors used for CT dosimetry. Physics in Medicine and Biology 57(16): N319-N328, 2012

On the determination of reference levels for quality assurance of flattening filter free photon beams in radiation therapy. Medical Physics 41(2): 021713-021713, 2014

Spectral dependence of the inhibition of photosynthesis under simulated global radiation in the unicellular green alga Dunaliella salina. Journal of Photochemistry & Photobiology B Biology 48(2-3): 166-173, 1999