Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert



Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert



Journal of Arthroplasty 22(3): 435-444



Polyethylene wear can compromise long-term performance of total knees. We investigated articular and backside wear rate of tibial inserts made from conventional vs highly cross-linked polyethylenes. The inserts were tested on a knee simulator at a frequency of 1.1 Hz using normal gait kinematics with a 7 degrees posterior slope for 7 million cycles. Gravimetrically, the combined articular and backside wear rate was 23 +/- 6 and 4.6 +/- 2 mm(3) per million cycles for the conventional and cross-linked inserts, respectively. We independently measured articular surface wear rates, which were 15 +/- 4 and 5 +/- 2 mm(3) per million cycles for conventional and cross-linked inserts, respectively. Electron beam cross-linked and subsequently melted polyethylene reduced the wear rate of polyethylene on articular and backside surfaces in a cruciate-retaining total knee design when tested on a knee simulator under simulated normal gait.

(PDF emailed within 0-6 h: $19.90)

Accession: 055783269

Download citation: RISBibTeXText

PMID: 17400100

DOI: 10.1016/j.arth.2006.07.014


Related references

Do temperature variations at the bearing surface during gait affect polyethylene wear in Charnley low-friction arthroplasty of the hip? Simulator study comparing UHMWPE and highly cross-linked polyethylene. Orthopaedics & Traumatology, Surgery & Research 102(6): 711-715, 2016

Wear comparison between a highly cross-linked polyethylene and conventional polyethylene against a zirconia femoral head: minimum 5-year follow-up. Journal of Arthroplasty 26(1): 45-49, 2011

Polyethylene wear and osteolysis after cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearings in patients younger than thirty years of age. Journal of Bone and Joint Surgery. American Volume 95(12): 1088-1093, 2013

Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis. Journal of Arthroplasty 23(3): 337-343, 2008

Wear is reduced in THA performed with highly cross-linked polyethylene. Clinical Orthopaedics and Related Research 467(7): 1765-1772, 2009

Third-body wear of highly cross-linked polyethylene in a hip simulator. Journal of Arthroplasty 18(5): 553-561, 2003

Wear of highly cross-linked polyethylene acetabular cup in Japan. Journal of Arthroplasty 21(7): 944-949, 2006

Once Annealed Highly Cross-Linked Polyethylene Exhibits Low Wear at 9 to 15 Years. Orthopedics 39(3): E565-E571, 2016

Second-generation annealed highly cross-linked polyethylene exhibits low wear. Clinical Orthopaedics and Related Research 470(6): 1696-1704, 2012

Continued improved wear with an annealed highly cross-linked polyethylene. Clinical Orthopaedics and Related Research 469(3): 825-830, 2011

Characteristics of highly cross-linked polyethylene wear debris in vivo. Journal of Biomedical Materials Research. Part B, Applied Biomaterials 101(3): 467-475, 2013

Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years. Clinical Orthopaedics and Related Research 467(12): 3290-3296, 2010

Short-term wear of Japanese highly cross-linked polyethylene in cementless THA. Archives of Orthopaedic and Trauma Surgery 128(9): 995-1000, 2008

A comparison of the wear of cross-linked polyethylene against itself with the wear of ultra-high molecular weight polyethylene against itself. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine 210(4): 297-300, 1996

Determination of reference geometry for polyethylene tibial insert wear analysis. Journal of Arthroplasty 26(3): 497-503, 2011