Simulation-based reconstruction of absolute activities from the (99m)Tc/(111)In dual-isotope SPECT/CT: phantom experiments and imaging of neuroendocrine tumors



Simulation-based reconstruction of absolute activities from the (99m)Tc/(111)In dual-isotope SPECT/CT: phantom experiments and imaging of neuroendocrine tumors



Physics in Medicine and Biology 58(10): 3339-3357



We investigate the quantitative accuracy of the reconstruction of absolute (99m)Tc and (111)In activities from (99m)Tc/(111)In dual-isotope SPECT studies. The separate reconstruction of two images is achieved by applying Monte Carlo simulation-based corrections for self-scatter and cross-talk between energy windows. For method evaluation, a series of (99m)Tc/(111)In physical phantom experiments was performed using a clinical SPECT/CT camera. The containers were filled with different ratios of (99m)Tc and (111)In activities to create cross-talk with varying severity levels. In addition, we illustrate the performance of our method by reconstructing images from four simultaneous (99m)Tc/(111)In SPECT/CT studies of neuroendocrine patients. Similarly to the phantom experiments, clinical cases provide examples with different severity of cross-talk. Phantom experiments showed that Monte Carlo simulation-based corrections improved both quantitative accuracy and visual properties of (99m)Tc and (111)In images. While the errors of absolute activities for both tracers in six containers ranged from 16% to 75% if no corrections for self-scatter and cross-talk were applied, these errors decreased to below 10% when images were reconstructed with the aforementioned corrections. These activities were measured using regions of interest larger than the true sizes of the containers in order to account for the spill-out effect. Analysis of patient studies confirmed that accurate simulation-based compensations improved resolution and contrast for both (99m)Tc and (111)In images.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 055785327

Download citation: RISBibTeXText

PMID: 23615334

DOI: 10.1088/0031-9155/58/10/3339


Related references

Quantitative image reconstruction for dual-isotope parathyroid SPECT/CT: phantom experiments and sample patient studies. Physics in Medicine and Biology 57(15): 4755-4769, 2012

Dual-isotope brain SPECT imaging with technetium-99m and iodine-123: validation by phantom studies. Journal of Nuclear Medicine 33(11): 2030-2035, 1992

Regularized image reconstruction algorithms for dual-isotope myocardial perfusion SPECT (MPS) imaging using a cross-tracer prior. IEEE Transactions on Medical Imaging 30(6): 1169-1183, 2011

Dual isotope brain spect using the headtome set 031 a phantom study and its clinical application. Journal of Nuclear Medicine 33(5 SUPPL): 1017, 1992

Model-based crosstalk compensation for simultaneous Tc99m∕I123 dual-isotope brain SPECT imaging. Medical Physics 34(9): 3530-3543, 2007

Dual-isotope brain SPECT imaging with technetium-99m and iodine-123: clinical validation using xenon-133 SPECT. Journal of Nuclear Medicine 33(11): 1919-1924, 1992

First assessment of simultaneous dual isotope ( 123 I/ 99m Tc) cardiac SPECT on two different CZT cameras: A phantom study. Journal of Nuclear Cardiology 25(5): 1692-1704, 2017

A new dual-isotope convolution cross-talk correction method: a Tl-201/Tc-99m SPECT cardiac phantom study. Medical Physics 21(10): 1577-1583, 1994

Scatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging. Annals of Nuclear Medicine 21(1): 25-32, 2007

Evaluation of simultaneous 201Tl/99mTc dual-isotope cardiac SPECT imaging with model-based crosstalk compensation using canine studies. Journal of Nuclear Cardiology 21(2): 329-340, 2014

Cardiac phantom evaluation of simultaneously acquired dual-isotope rest thallium-201/stress technetium-99m SPECT images. Journal of Nuclear Medicine 34(11): 1998-2006, 1993

Comparison of single time-point [111-In] pentetreotide SPECT/CT with dual time-point imaging of neuroendocrine tumors. Clinical Nuclear Medicine 36(1): 25-31, 2011

Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc/123I dual-isotope simultaneous acquisition brain SPECT. Medical Physics 36(6): 2021-2033, 2009

Optimizing Somatostatin Receptor Imaging in Patients With Neuroendocrine Tumors: The Impact of 99mTc-HYNICTOC SPECT/SPECT/CT Versus 68Ga-DOTATATE PET/CT Upon Clinical Management. Clinical Nuclear Medicine 42(12): 905-911, 2017

Bayesian reconstruction for SPECT: Validation with monte carlo simulation, experimental phantom, and real patient data. International Journal of Imaging Systems and Technology 1(2): 149-168, 1989