+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Spontaneous effort causes occult pendelluft during mechanical ventilation



Spontaneous effort causes occult pendelluft during mechanical ventilation



American Journal of Respiratory and Critical Care Medicine 188(12): 1420-1427



In normal lungs, local changes in pleural pressure (P(pl)) are generalized over the whole pleural surface. However, in a patient with injured lungs, we observed (using electrical impedance tomography) a pendelluft phenomenon (movement of air within the lung from nondependent to dependent regions without change in tidal volume) that was caused by spontaneous breathing during mechanical ventilation. To test the hypotheses that in injured lungs negative P(pl) generated by diaphragm contraction has localized effects (in dependent regions) that are not uniformly transmitted, and that such localized changes in P(pl) cause pendelluft. We used electrical impedance tomography and dynamic computed tomography (CT) to analyze regional inflation in anesthetized pigs with lung injury. Changes in local P(pl) were measured in nondependent versus dependent regions using intrabronchial balloon catheters. The airway pressure needed to achieve comparable dependent lung inflation during paralysis versus spontaneous breathing was estimated. In all animals, spontaneous breathing caused pendelluft during early inflation, which was associated with more negative local P(pl) in dependent regions versus nondependent regions (-13.0 ± 4.0 vs. -6.4 ± 3.8 cm H2O; P < 0.05). Dynamic CT confirmed pendelluft, which occurred despite limitation of tidal volume to less than 6 ml/kg. Comparable inflation of dependent lung during paralysis required almost threefold greater driving pressure (and tidal volume) versus spontaneous breathing (28.0 ± 0.5 vs. 10.3 ± 0.6 cm H2O, P < 0.01; 14.8 ± 4.6 vs. 5.8 ± 1.6 ml/kg, P < 0.05). Spontaneous breathing effort during mechanical ventilation causes unsuspected overstretch of dependent lung during early inflation (associated with reciprocal deflation of nondependent lung). Even when not increasing tidal volume, strong spontaneous effort may potentially enhance lung damage.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 055889008

Download citation: RISBibTeXText

PMID: 24199628

DOI: 10.1164/rccm.201303-0539oc


Related references

Spontaneous Effort During Mechanical Ventilation: Maximal Injury With Less Positive End-Expiratory Pressure. Critical Care Medicine 44(8): E678-E688, 2016

Spontaneous respiratory effort during mechanical ventilation in infants with and without acute respiratory distress. Early Human Development 25(2): 69-74, 1991

The role of spontaneous effort during mechanical ventilation: normal lung versus injured lung. Journal of Intensive Care 3: 18, 2015

Influence of different methods of synchronized mechanical ventilation on ventilation, gas exchange, patient effort, and blood pressure fluctuations in premature neonates. Pediatric Pulmonology 22(5): 305-313, 1996

Diaphragmatic movement studied with ultrasound during spontaneous breathing and mechanical ventilation with intermittent positive pressure ventilation (IPPV) and airway pressure release ventilation (APRV) in man. Anaesthesiologie und Reanimation 19(2): 43-47, 1994

Diaphragmatic motion and regional ventilation during spontaneous and mechanical ventilation in dogs. American Review of Respiratory Disease 125(4 Part 2): 209, 1982

An evaluation of apnea or spontaneous ventilation in early recovery following mechanical ventilation in the anesthetized horse. Veterinary Anaesthesia and Analgesia 28(1): 26-33, 2001

Interfacing between spontaneous breathing and mechanical ventilation affects ventilation-perfusion distributions in experimental bronchoconstriction. American Journal of Respiratory and Critical Care Medicine 151(4): 993-999, 1995

Gas exchange during mechanical ventilation and spontaneous breathing. Intermittent mandatory ventilation after open heart surgery. Chest 90(1): 11-17, 1986

Ventilation-perfusion distributions during mechanical ventilation with superimposed spontaneous breathing in canine lung injury. American Journal of Respiratory and Critical Care Medicine 150(1): 101-108, 1994

Transition of patients to spontaneous respiration after a prolonged mechanical ventilation with the involvement of various methods of auxiliary ventilation. Georgian Medical News 2006(141): 7, 2006

Regional ventilation during spontaneous breathing and mechanical ventilation in dogs. Journal of Applied Physiology 63(6): 2467-2475, 1987

Minimizing breathing effort during mechanical ventilation. Zapol, W M And F Lemaire (Ed ) Lung Biology in Health And Disease, Vol 50 Adult Respiratory Distress Syndrome Xxi+586p Marcel Dekker, Inc : New York, New York, Usa; Basel, Switzerland Illus 163-198, 1991

Ventilation perfusion distribution during inhalation anesthesia effects of spontaneous breathing mechanical ventilation and positive end expiratory pressure. Acta Anaesthesiologica Scandinavica 25(4): 360-371, 1981

Phenomena observed during the passage from positive pressure mechanical ventilation to spontaneous ventilation success or failure mechanisms of weaning. Societe De Reanimation De Langue Francaise Reanimation Et Medecine D'urgence; (Resuscitation And Emergency Medicine); Meeting Of The Societe De Reanimation De Langue Francaise (French Language Society For Resuscitation), November 1986 447p Expansion Scientifique Francaise: Paris, France Illus 35-44, 1987