Spontaneous lead breakage in implanted spinal cord stimulation systems



Korean Journal of Pain 23(1): 78-81



Spinal cord stimulation (SCS) has become an established clinical option for treatment of refractory chronic pain. Current hardware and implantation techniques for SCS are already highly developed and continuously improving; however, equipment failures over the course of long-term treatment are still encountered in a relatively high proportion of the cases treated with it. Percutaneous SCS leads seem to be particularly prone to dislocation and insulation failures. We describe our experience of lead breakage in the inserted spinal cord stimulator to a complex regional pain syndrome patient who obtained satisfactory pain relief after the revision of SCS.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 055889987

Download citation: RISBibTeXText

PMID: 20552080

DOI: 10.3344/kjp.2010.23.1.78


Related references

Efficacy and Complications Profile of Surgically Implanted Versus Percutaneously Implanted Spinal Cord Stimulation Systems. Anesthesiology Abstracts of Scientific Papers Annual Meeting ( ): Abstract No A-928, 2002

Spinal cord stimulation with percutaneous leads after loss of coverage with implanted surgical lead. Neuromodulation 13(2): 117-120, 2010

Spinal cord stimulation with implanted epidural paddle lead relieves chronic axial low back pain. Journal of Pain Research 7: 465-470, 2014

Percutaneous implanted paddle lead for spinal cord stimulation: technical considerations and long-term follow-up. Neuromodulation 15(4): 402-407, 2012

Prevention of mechanical failures in implanted spinal cord stimulation systems. Neuromodulation 9(3): 183-191, 2006

Implanted functional neuromuscular stimulation systems for individuals with cervical spinal cord injuries: Clinical case reports. Archives of Physical Medicine and Rehabilitation 77(11): 1119-1128, 1996

Evaluation of a dual quadripolar surgically implanted spinal cord stimulation lead for failed back surgery patients with chronic low back and leg pain. Neuromodulation 8(4): 219-224, 2005

Trial spinal cord stimulator reimplantation following lead breakage after third birth. Pain Physician 13(6): 523-526, 2011

Bipolar dual-lead spinal cord stimulation between two electrodes on the ventral and dorsal sides of the spinal cord: consideration of putative mechanisms. Acta Neurochirurgica 160(3): 639-643, 2018

An algorithmic programming approach for back pain symptoms in failed back surgery syndrome using spinal cord stimulation with a multicolumn surgically implanted epidural lead: a multicenter international prospective study. Pain Practice 15(3): 195-207, 2015

Compression of Thoracic Spinal Cord with Decreased Cerebrospinal Fluid Space After Implantation of Paddle Lead Spinal Cord Stimulation at T9: A Three-Dimensional Myelographic Computed Tomography Study. World Neurosurgery 118: E323-E334, 2018

Clinical Outcomes of 1 kHz Subperception Spinal Cord Stimulation in Implanted Patients With Failed Paresthesia-Based Stimulation: Results of a Prospective Randomized Controlled Trial. Neuromodulation 19(7): 731-737, 2016

Dual lead spinal cord stimulation using octad lead for central post-stroke pain. No Shinkei Geka. Neurological Surgery 40(4): 325-329, 2012

Spinal cord stimulation for refractory angina in a patient implanted with a cardioverter defibrillator. Pacing and Clinical Electrophysiology 30(1): 143-146, 2007

Chronically implanted electrodes for repeated stimulation and recording of spinal cord potentials. Journal of Neuroscience Methods 141(1): 125-134, 2005