+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Stable multipass Fabry-Perot interferometer: design and analysis



Stable multipass Fabry-Perot interferometer: design and analysis



Applied Optics 16(9): 2514-2520



A multipass plane parallel Fabry-Perot interferometer (FPP-M) can give extremely high contrast (in excess of 10(6)) over a wide range of finesse values without reducing the transmission significantly. Curves and tables are provided along with a brief outline of Chabbal's analysis for the residual defects of the Fabry-Perot mirrors to aid a quick assessment of the optimum parameters for a desired spectrometric work. The exploitation of the advantages of an FPP-M depends upon the maintenance of its stability. So, we have constructed a passive interferometer of low thermal expansion material, Cer-Vit, along with nonkinematic design and thermally compensated mirror mounts to achieve long term stability without the use of a servo control device.

(PDF emailed within 0-6 h: $19.90)

Accession: 055901048

Download citation: RISBibTeXText

PMID: 20168960

DOI: 10.1364/AO.16.002514


Related references

Determination of a Fabry-Perot multipass interferometer instrumental function. Applied Optics 28(12): 2191-2193, 1989

Tandem multipass Fabry-Perot interferometer for Brillouin scattering. Applied Optics 20(8): 1374-1381, 1981

Closed-form expressions to fit data obtained with a multipass Fabry-Perot interferometer. Applied Optics 34(1): 69-86, 1995

Stable and rugged etalon for the Dynamics Explorer Fabry-Perot interferometer. 1: Design and construction. Applied Optics 21(21): 3896-3902, 1982

Stable and well adjustable fabry-perot interferometer. Applied Optics 10(2): 443-443, 1971

Intensity transmitted by a Fabry-Perot etalon with another internal Fabry-Perot interferometer. Applied Optics 20(12): 2117-2120, 1981

Design methodology for a Fabry-Perot interferometer used as a concentration sensor. Applied Optics 41(15): 2847-2857, 2002

Stable and rugged etalon for the Dynamics Explorer Fabry-Perot interferometer. 2: Performance. Applied Optics 21(21): 3903-3912, 1982

Design of a multiple-zone aperture and application to a Fabry-Perot interferometer. Applied Optics 19(10): 1622-1629, 1980

Highly compact fiber Fabry-Perot interferometer: A new instrument design. Review of Scientific Instruments 87(11): 115102-115102, 2016

Modeling and analysis of an extrinsic Fabry-Perot interferometer cavity. Applied Optics 44(16): 3192-3196, 2005

Doppler line profile analysis for a multichannel Fabry-Perot interferometer. Applied Optics 23(4): 612-612, 1984

Wind-velocity lidar measurements by use of a Mach-Zehnder interferometer, comparison with a Fabry-Perot interferometer. Applied Optics 43(1): 173-182, 2004

A high-contrast multipass Fabry--Perot spectrometer. Journal of Physics E: Scientific Instruments 10(2): 150-154, 1977

Polar cap mesosphere wind observations: comparisons of simultaneous measurements with a Fabry-Perot interferometer and a field-widened Michelson interferometer. Applied Optics 39(24): 4284-4291, 2008