+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Stratospheric temperature measurement with scanning Fabry-Perot interferometer for wind retrieval from mobile Rayleigh Doppler lidar



Stratospheric temperature measurement with scanning Fabry-Perot interferometer for wind retrieval from mobile Rayleigh Doppler lidar



Optics Express 22(18): 21775-21789



Temperature detection remains challenging in the low stratosphere, where the Rayleigh integration lidar is perturbed by aerosol contamination and ozone absorption while the rotational Raman lidar is suffered from its low scattering cross section. To correct the impacts of temperature on the Rayleigh Doppler lidar, a high spectral resolution lidar (HSRL) based on cavity scanning Fabry-Perot Interferometer (FPI) is developed. By considering the effect of the laser spectral width, Doppler broadening of the molecular backscatter, divergence of the light beam and mirror defects of the FPI, a well-behaved transmission function is proved to show the principle of HSRL in detail. Analysis of the statistical error of the HSRL is carried out in the data processing. A temperature lidar using both HSRL and Rayleigh integration techniques is incorporated into the Rayleigh Doppler wind lidar. Simultaneous wind and temperature detection is carried out based on the combined system at Delhi (37.371°N, 97.374°E; 2850 m above the sea level) in Qinghai province, China. Lower Stratosphere temperature has been measured using HSRL between 18 and 50 km with temporal resolution of 2000 seconds. The statistical error of the derived temperatures is between 0.2 and 9.2 K. The temperature profile retrieved from the HSRL and wind profile from the Rayleigh Doppler lidar show good agreement with the radiosonde data. Specifically, the max temperature deviation between the HSRL and radiosonde is 4.7 K from 18 km to 36 km, and it is 2.7 K between the HSRL and Rayleigh integration lidar from 27 km to 34 km.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 055935527

Download citation: RISBibTeXText

PMID: 25321553

DOI: 10.1364/oe.22.021775


Related references

Fabry-Perot interferometer based Mie Doppler lidar for low tropospheric wind observation. Applied Optics 46(29): 7120-7131, 2007

Direct-detection Doppler wind measurements with a Cabannes-Mie lidar: a. Comparison between iodine vapor filter and Fabry-Perot interferometer methods. Applied Optics 46(20): 4434-4443, 2007

Wind-velocity lidar measurements by use of a Mach-Zehnder interferometer, comparison with a Fabry-Perot interferometer. Applied Optics 43(1): 173-182, 2004

High-spectral-resolution Mie Doppler lidar based on a two-stage Fabry-Perot etalon for tropospheric wind and aerosol accurate measurement. Applied Optics 58(9): 2216-2225, 2019

All-fiber upconversion high spectral resolution wind lidar using a Fabry-Perot interferometer. Optics Express 24(17): 19322-19336, 2016

Mobile Rayleigh Doppler lidar for wind and temperature measurements in the stratosphere and lower mesosphere. Optics Express 22(Suppl. 5): A1203-A1221, 2014

Monostatic coaxial 1.5 μm laser Doppler velocimeter using a scanning Fabry-Perot interferometer. Optics Express 21(18): 21105-21112, 2013

A two-channel Fabry-Perot interferometer for the measurement of Doppler temperatures. Applied Optics 6(7): 1205-1207, 1967

Ultraviolet Rayleigh-Mie lidar with Mie-scattering correction by Fabry-Perot etalons for temperature profiling of the troposphere. Applied Optics 44(7): 1305-1314, 2005

Ultraviolet Rayleigh-Mie lidar by use of a multicavity Fabry-Perot filter for accurate temperature profiling of the troposphere. Applied Optics 44(30): 6474-6478, 2005

Fabry-Perot etalon aperture requirements for direct detection Doppler wind lidar from Earth orbit. Applied Optics 38(27): 5859-5866, 2008

Fabry-Perot-interferometer imaging system for thermospheric temperature and wind measurements. Applied Optics 19(13): 2206-2209, 1980

Optical scanning extrinsic Fabry-Perot interferometer for absolute microdisplacement measurement. Applied Optics 36(34): 8858-8861, 2008

Coincident Thermos3pheric Wind Measurements using ground-based Doppler Asymmetric Spatial Heterodyne DASH and Fabry?Perot Interferometer FPI instruments. Journal of Atmospheric and Solar-Terrestrial Physics 86: 92-98, 2012

Nonlinear regression method for estimating neutral wind and temperature from Fabry-Perot interferometer data. Applied Optics 53(4): 666-673, 2014