Super-resolution variable-dose imaging in digital radiography: quality and dose reduction with a fluoroscopic flat-panel detector



Super-resolution variable-dose imaging in digital radiography: quality and dose reduction with a fluoroscopic flat-panel detector



International Journal of Computer Assisted Radiology and Surgery 6(5): 663-673



Super-resolution (SR) image processing produces a high-resolution image from a series of low-resolution images. The aim of this study was to evaluate SR-images based on fluoroscopic flat-detector (FD) acquisition at different frame rates. Fluoroscopic FD-sequences with 20 frames were obtained with varying pulse frequencies of (1) a line pair resolution phantom; (2) a low-contrast resolution phantom, and (3) a human knee specimen. Super-resolution digital radiographs (SR-Radiographs) were generated from each sequence. Variable-dose images were simulated by constructing SR-Radiographs using 6 and 12 frames from the corresponding fluoroscopic sequence. "Single Shot" and Computed Radiography (CR) images were obtained for comparison based on dynamic range and sharpness of bone detail structures. Patient-derived SR-Radiographic images were constructed to demonstrate clinical examples. The spatial resolution of SR-radiographs obtained at 12.5 frames per second (fps) and 6 fps were comparable with CR and "Single Shot" images, providing ~3.5 line pairs per mm (l p/mm). Similarly, low-contrast resolution of SR-radiographs obtained at 12.5, 6, and 30 fps were equivalent to CR and "Single Shot" images. The human knee specimen SR-radiograph obtained using 12 FD images at 12.5 fps was superior to a CR image in overall image quality, with a dose reduction of 75%. Variable-dose SR-radiographic simulations suggest a dose saving potential of 90-95% when using 6 FD images at 12.5 fps or 6 fps, respectively. The phantom testing images and simulation results demonstrate that diagnostic quality SR-radiographic images of skeletal extremities can be synthesized using a flat-panel detector system designed primarily for angiography. SR-images obtained with substantially reduced radiation dose are feasible, and this technology may improve digital radiography for pediatric, neonatal radiography, or mammography applications. Further testing is needed to validate super-resolution techniques in other body regions and for different flat-detector systems.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 056010850

Download citation: RISBibTeXText

PMID: 21298404

DOI: 10.1007/s11548-011-0545-9


Related references

Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography. Ajr. American Journal of Roentgenology 181(4): 923-929, 2003

Routine chest radiography using a flat-panel detector: image quality at standard detector dose and 33% dose reduction. Ajr. American Journal of Roentgenology 178(1): 169-171, 2002

Radiation dose reduction in scoliosis patients: low-dose full-spine radiography with digital flat panel detector and image stitching system. Rofo 183(7): 645-649, 2011

Radiation dose and image quality in diagnostic radiology. Optimization of the dose-image quality relationship with clinical experience from scoliosis radiography, coronary intervention and a flat-panel digital detector. Acta Radiologica. Supplementum 43(427): 1-43, 2002

Chest radiography with a flat-panel detector: image quality with dose reduction after copper filtration. Radiology 237(2): 691-700, 2005

Routine skeleton radiography using a flat-panel detector: image quality and clinical acceptance at 50% dose reduction. Investigative Radiology 38(4): 230-235, 2003

Radiation dose reduction with frame rate conversion in X-ray fluoroscopic imaging systems with flat panel detector: basic study and clinical retrospective analysis. European Radiology 29(2): 985-992, 2019

Digital amorphous silicon flat-panel detector radiography at different exposure doses versus mammography film: possibility of radiation dose reduction in detecting rheumatologic bone defects. Acta Radiologica 49(2): 157-166, 2008

Ultra-low-dose computed tomography system with a flat panel detector: assessment of radiation dose reduction and spatial and low contrast resolution. Radiation Medicine 26(10): 627-635, 2008

Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography. Ajr. American Journal of Roentgenology 171(1): 23-27, 1998

Radiation dose reduction in chest radiography using a flat-panel amorphous silicon detector. Clinical Radiology 57(10): 902-907, 2002

Varied tube potential with constant effective dose at lumbar spine radiography using a flat-panel digital detector. Radiation Protection Dosimetry 114(1-3): 240-245, 2005

Flat panel digital radiography compared with storage phosphor computed radiography: assessment of dose versus image quality in phantom studies. Investigative Radiology 37(11): 609-614, 2002

Dose reduction of radiographs of the pediatric pelvis for diagnosing hip dysplasia using a digital flat-panel detector system. Rofo 175(1): 112-117, 2003

Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature. European Radiology 14(5): 827-834, 2004