+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients



Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients



Pediatrics 122(2): 293-298



The goal was to assess the time to recognition of apnea in a simulated pediatric sedation scenario, with and without supplemental oxygen. A pediatric human patient simulator mannequin was used to simulate apnea in a 6-year-old patient who received sedation for resetting of a fractured leg. Thirty pediatricians participating in a credentialing course for sedation were randomly assigned to 2 groups. Those in group 1 (N = 15) used supplemental oxygen, and those in group 2 (N = 15) did not use supplemental oxygen. A third group (N = 10), consisting of anesthesiology residents (postgraduate years 2 and 3 equivalent), performed the scenario with oxygen supplementation, to ensure validity and reliability of the simulation. The time interval from simulated apnea to bag-mask ventilation was recorded. Oxygen saturation and Paco(2) values were recorded. All recorded variables and measurements were compared between the groups. The time interval for bag-mask ventilation to occur in group 1 (oxygen supplementation) was significantly longer than that in group 2 (without oxygen supplementation) (173 +/- 130 and 83 +/- 42 seconds, respectively). The time interval for bag-mask ventilation to occur was shorter in group 3 (anesthesiology residents) (24 +/- 6 seconds). Paco(2) reached a higher level in group 1 (75 +/- 26 mmHg), compared with groups 2 and 3 (48 +/- 10 and 42 +/- 3 mmHg, respectively). There was no significant difference between the groups in oxygen saturation values at the time of clinical detection of apnea (93 +/- 5%, 88 +/- 5%, and 94 +/- 7%, respectively). Hypoventilation and apnea are detected more quickly when patients undergoing sedation breathe only air. Supplemental oxygen not only does not prevent oxygen desaturation but also delays the recognition of apnea.

(PDF emailed within 0-6 h: $19.90)

Accession: 056015111

Download citation: RISBibTeXText

PMID: 18676546

DOI: 10.1542/peds.2007-2385


Related references

Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. Chest 126(5): 1552-1558, 2004

Routine use of pulse oximetry and supplemental oxygen during endoscopic procedures under conscious sedation: British beef or common sense?. Endoscopy 28(8): 718-721, 1996

The effect of supplemental oxygen on apnea and oxygen saturation during pediatric conscious sedation. Pediatric Dentistry 20(1): 8-16, 1998

Pulse oximetry: Mandatory for sedation during regional/local Anaesthesia (but watch for hypoventilation!). Indian Journal of Anaesthesia 55(3): 217-219, 2011

Pulse Oximetry for Tapering Supplemental Oxygen in Hospitalized Patients. Chest Journal 92(4): 713-716, 1987

Pulse oximetry and capnography monitoring of pediatric sedation patients. Journal of Dental Research 68(SPEC ISSUE): 198, 1989

Pulse oximetry for tapering supplemental oxygen in hospitalized patients. Evaluation of a protocol. Chest 92(4): 713-716, 1987

Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients. Chest 97(6): 1420-1425, 1990

Pulse oximetry recorded from the Phone Oximeter for detection of obstructive sleep apnea events with and without oxygen desaturation in children. Conference Proceedings 2015: 7692-7695, 2016

Pulse oximetry for the detection of obstructive sleep apnea syndrome: can the memory capacity of oxygen saturation influence their diagnostic accuracy?. Sleep Disorders 2011: 427028-427028, 2011

Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?. Sleep Disorders 2011: 1-9, 2011

The physiological effects of supplemental oxygen versus nitrous oxide/oxygen during conscious sedation of pediatric dental patients. Pediatric Dentistry 22(2): 125-133, 2000

Utility of the Pediatric Sleep Questionnaire and Pulse Oximetry as Screening Tools in Pediatric Patients with Suspected Obstructive Sleep Apnea Syndrome. Sleep Disorders 2012: 1-6, 2012

Utility of the pediatric sleep questionnaire and pulse oximetry as screening tools in pediatric patients with suspected obstructive sleep apnea syndrome. Sleep Disorders 2012: 819035-819035, 2012

Improving diagnostic ability of blood oxygen saturation from overnight pulse oximetry in obstructive sleep apnea detection by means of central tendency measure. Artificial Intelligence in Medicine 41(1): 13-24, 2007