Surface modification of hydrogel intraocular lenses to prevent cell proliferation



Surface modification of hydrogel intraocular lenses to prevent cell proliferation



Journal of Applied Biomaterials and Biomechanics 2(3): 183-190



Intraocular lenses made from a hydrogel matrix were coated with a bioactive polymer exhibiting sulfonate and carboxylate groups. The anchorage of the macromolecular chains bearing the anionic groups to the hydrogel implant surface was obtained by an intermolecular reaction of the photosensitive groups attached to the ionic polymer, in order to obtain a pseudo-interpenetrated network. Cell proliferation assays performed on coated and uncoated hydrogel lenses showed an inhibiting effect of the bioactive polymer coating by up to 40% at day 6. The inhibiting effect was due to the presence and the distribution of both sulfonate and carboxylate groups along the macromolecular chains, which led to the appearance of ""bioactive sites"" allowing controlled interactions of surface, adhesive proteins and cells. (Journal of Applied Biomaterials & Biomechanics 2004; 2: 183-9).

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 056023668

Download citation: RISBibTeXText

PMID: 20803437


Related references

In vivo human lens epithelial cell proliferation on the anterior surface of PMMA intraocular lenses. British Journal of Ophthalmology 80(5): 469-474, 1996

In vitro evaluation of inflammatory cell response after CF4 plasma surface modification of poly(methyl methacrylate) intraocular lenses. Journal of Cataract and Refractive Surgery 19(3): 364-370, 1993

In vivo observation of surface precipitates of 200 consecutive hydrogel intraocular lenses. Ophthalmologica. Journal International d'Ophtalmologie. International Journal of Ophthalmology. Zeitschrift für Augenheilkunde 204(1): 13-18, 1992

Surface modification of silicone intraocular implants to inhibit cell proliferation. Biomacromolecules 6(5): 2630-2637, 2005

Surface modification of model hydrogel contact lenses with hyaluronic acid via thiol-ene "click" chemistry for enhancing surface characteristics. Journal of Biomaterials Applications 32(4): 446-462, 2017

Surface Modification of Intraocular Lenses. Chinese Medical Journal 129(2): 206-214, 2016

Helping us understand surface modification of intraocular lenses. Journal of Cataract and Refractive Surgery 17(2): 129, 1991

The effect of hydrogel and silicone hydrogel contact lenses on the measurement of intraocular pressure with rebound tonometry. Contact Lens and Anterior Eye 34(6): 260-265, 2011

Late postoperative opacification of hydrogel intraocular lenses: analysis of 13 explanted lenses. Klinische Monatsblatter für Augenheilkunde 226(4): 264-271, 2009

In vivo implantation of hydrophobic acrylic intraocular lenses with surface modification. Eye Science 28(4): 176-179, 2013

Surface modification of intraocular lenses to reduce corneal endothelial damage. Journal - American Intra-Ocular Implant Society 5(2): 123-130, 1979

Effects of surface modification of intraocular lenses on foreign body reaction. Nippon Ganka Gakkai Zasshi 109(5): 267-273, 2005

A retrospective analysis of heparin-surface-modified intraocular lenses versus regular polymethylmethacrylate intraocular lenses in patients with uveitis. Documenta Ophthalmologica. Advances in Ophthalmology 92(1): 41-50, 1996

Lens epithelial cell layer formation related to hydrogel foldable intraocular lenses. Journal of Cataract and Refractive Surgery 25(12): 1637-1640, 1999

Effect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses. Journal of Cataract and Refractive Surgery 27(10): 1662-1669, 2001