The effect of gantry and collimator angles on leaf limited velocity and position in dynamic multileaf collimator intensity-modulated radiation therapy



The effect of gantry and collimator angles on leaf limited velocity and position in dynamic multileaf collimator intensity-modulated radiation therapy



Physics in Medicine and Biology 55(11): 3101-3113



The purpose of the study is to evaluate the limiting velocity (LV) of a multileaf collimator and the leaf position in various collimator and gantry angles. Both leading leaves and trailing leaves began to move with a constant acceleration from 0 to 4 cm s(-1). When the beam hold occurred, the leaf velocity was defined as the leaf LV. Dynamic irradiation was performed at eight gantry angles of every 45 degrees with three different collimator angles. The analysis of the LV and the leaf position was performed with a log file from a leaf motion controller. The mean LVs for Varian Clinac 21EX (21EX) ranged from 2.51 to 3.10 cm s(-1). The mean LVs for Clinac 600C ranged from 2.91 to 3.12 cm s(-1). When only central 5 mm leaves of 21EX moved, LVs were significantly higher than those when all 60 pairs of leaf moved, while the leaf position inconsistencies of the two accelerators were within 1 mm at the leaf velocities from 0.5 to 2.0 cm s(-1). It was recognized that the LV was affected by gravity. This measurement method can be utilized as routine quality assurance for a dynamic multileaf collimator (DMLC) is and easily reproducible.

(PDF emailed within 0-6 h: $19.90)

Accession: 056303218

Download citation: RISBibTeXText

PMID: 20463373

DOI: 10.1088/0031-9155/55/11/008



Related references

Intensity modulated arc deliveries approximated by a large number of fixed gantry position sliding window dynamic multileaf collimator fields. Medical Physics 29(10): 2359-2365, 2002

Dynamic multileaf collimator performance for intensity modulated radiation therapy. International Journal of Radiation Oncology Biology Physics 48(3 Supplement): 341, 2000

Integration of real-time internal electromagnetic position monitoring coupled with dynamic multileaf collimator tracking: an intensity-modulated radiation therapy feasibility study. International Journal of Radiation Oncology, Biology, Physics 74(3): 868-875, 2009

Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator. Journal of Applied Clinical Medical Physics 7(3): 43-54, 2007

Effect of beam number on organ-at-risk sparing in dynamic multileaf collimator delivery of intensity modulated radiation therapy. Medical Physics 34(10): 3752-3759, 2007

Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy. Nihon Hoshasen Gijutsu Gakkai Zasshi 67(5): 497-506, 2011

Effect of multileaf collimator leaf width on physical dose distributions in the treatment of CNS and head and neck neoplasms with intensity modulated radiation therapy. Medical Physics 29(6): 1116-1119, 2002

A modified method of planning and delivery for dynamic multileaf collimator intensity-modulated radiation therapy. International Journal of Radiation Oncology Biology Physics 47(1): 241-245, April 1, 2000

Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: comparison of dynamic and segmental methods. Medical Physics 28(12): 2441-2449, 2002

Improving the resolution of dynamic intensity modulated radiation therapy delivery by reducing the multileaf collimator sampling distance. Medical Physics 30(10): 2793-2803, 2003

Volumetric modulated arc therapy with dynamic collimator rotation for improved multileaf collimator tracking of the prostate. RadioTherapy and Oncology 122(1): 109-115, 2016

A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery. International Journal of Radiation Oncology, Biology, Physics 71(5): 1526-1536, 2008

Impact of the number of control points has on isodose distributions in a dynamic multileaf collimator intensity-modulated radiation therapy delivery. Medical Dosimetry 37(4): 412-416, 2013

Intensity-modulated radiation therapy for mesothelioma: impact of multileaf collimator leaf width and pencil beam size on planning quality and delivery efficiency. International Journal of Radiation Oncology, Biology, Physics 62(5): 1525-1534, 2005

Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy. Medical Physics 28(5): 752-756, 2001