The influence of different speech processor and hearing aid settings on speech perception outcomes in electric acoustic stimulation patients



The influence of different speech processor and hearing aid settings on speech perception outcomes in electric acoustic stimulation patients



Ear and Hearing 29(1): 76-86



Electric acoustic stimulation (EAS) is an increasingly popular means of treating individuals with a steeply sloping mid-to-high frequency hearing loss, who traditionally do not benefit from hearing instruments. These persons often have too much residual hearing to be considered for a cochlear implant. Several studies have demonstrated the ability both to preserve the remaining low-frequency hearing in these individuals, and to provide significant benefit through combining a cochlear implant with a hearing aid to amplify the same ear. These improvements in performance have been especially noted in noise. Often overlooked is that these outcomes may be influenced by the fitting parameters of both the cochlear implant and the hearing aid. This study assessed four EAS subjects, with a minimum of 1 month's EAS use, on eight different fitting parameters. Sentence testing in different noise levels (+15, +10, and +5 dB SPL) was conducted. Subjects also evaluated each condition using a visual analogue scale. Results demonstrated that a reduced overlap of cochlear implant and hearing aid amplification produced best results across listening conditions. The hearing aid should be fit to a patient-specific modified audiogram at least up to the point where low-frequency hearing is not measurable. The cochlear implant should be fit from a higher frequency point than is standard in patients without residual hearing in the implanted ear, to provide reduced overlap with the amplification provided by the hearing aid. Therefore, a small amount of overlap between the frequency ranges used by the hearing aid and the cochlear implant seems beneficial.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 056380724

Download citation: RISBibTeXText

PMID: 18091097


Related references

Hearing preservation and speech perception outcomes with electric-acoustic stimulation after 12 months of listening experience. Laryngoscope 123(10): 2509-2515, 2013

Combined electric and acoustic hearing performance with Zebra® speech processor: speech reception, place, and temporal coding evaluation. Cochlear Implants International 14(3): 150-157, 2013

Electric-Acoustic Stimulation After Reimplantation: Hearing Preservation and Speech Perception. Otology and Neurotology 40(2): E94-E98, 2019

Frequency overlap between electric and acoustic stimulation and speech-perception benefit in patients with combined electric and acoustic stimulation. Ear and Hearing 31(2): 195-201, 2010

Influence of Test Condition on Speech Perception With Electric-Acoustic Stimulation. American Journal of Audiology 24(4): 520-528, 2015

Speech perception studies using a multichannel electrotactile speech processor residual hearing and lipreading. Journal of the Acoustical Society of America 85(6): 2593-2607, 1989

A new combined speech processor for electric and acoustic stimulation--eight months experience. Orl; Journal for Oto-Rhino-Laryngology and its Related Specialties 70(6): 359-365, 2008

Effects of minimum stimulation settings for the Med El Tempo+ speech processor on speech understanding. Ear and Hearing 26(4 Suppl.): 2s-6s, 2005

Perception of sentences, words, and speech features by profoundly hearing-impaired children using a multichannel electrotactile speech processor. Journal of the Acoustical Society of America 88(3): 1374-1384, 1990

Clear speech perception in acoustic and electric hearing. Journal of the Acoustical Society of America 116(4 Pt 1): 2374-2383, 2004

Acceptance and fitting of the DUET device - a combined speech processor for electric acoustic stimulation. Advances in Oto-Rhino-Laryngology 67: 81-87, 2010

Improved speech reception and sound quality with the DUET2 audio processor for electric acoustic stimulation. Acta Oto-Laryngologica 135(10): 1022-1029, 2015

Contributions of electric and acoustic hearing to bimodal speech and music perception. Plos one 10(3): E0120279, 2015

Speech perception in simulated electric hearing exploits information-bearing acoustic change. Journal of the Acoustical Society of America 133(2): El136-El141, 2013

Fundamental frequency is critical to speech perception in noise in combined acoustic and electric hearing. Journal of the Acoustical Society of America 130(4): 2054-2062, 2011