+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

The patient inflating valve in anaesthesia and resuscitation breathing systems



The patient inflating valve in anaesthesia and resuscitation breathing systems



Anaesthesia and Intensive Care 41(2): 163-174



Patient inflating valves combined with self-inflating bags are known to all anaesthetists as resuscitation devices and are familiar as components of draw-over anaesthesia systems. Their variants are also commonplace in transfer and home ventilators. However, the many variations in structure and function have led to difficulties in their optimal use, definition and classification. After reviewing the relevant literature, we defined a patient inflating valve as a one-way valve that closes an exit port to enable lung inflation, also permitting exhalation and spontaneous breathing, the actions being automatic. We present a new classification based on the mechanism of valve opening/closure; namely elastic recoil of a flexible flap/diaphragm, sliding spindle opened by a spring/magnet or a hollow balloon collapsed by external pressure. The evolution of these valves has been driven by the difficulties documented in critical incidents, which we have used along with information from modern International Organization for Standardization standards to identify 13 ideal properties, the top six of which are non-jamming, automatic, no bypass effect, no rebreathing or air entry at patient end, low resistance, robust and easy to service. The Ambu and the Laerdal valves have remained popular due to their simplicity and reliability. Two new alternatives, the Fenton and Diamedica valves, offer the benefits of location away from the patient while retaining a small functional dead space. They also offer the potential for greater use of hybrid continuous flow/draw-over systems that can operate close to atmospheric pressure. The reliable application of positive end-expiratory pressure/continuous positive airway pressure remains a challenge.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 056428821

Download citation: RISBibTeXText

PMID: 23530783


Related references

Born not breathing: A randomised trial comparing two self-inflating bag-masks during newborn resuscitation in Tanzania. Resuscitation 116: 66-72, 2017

The effect of a PEEP valve on a Laerdal neonatal self-inflating resuscitation bag. Journal of Paediatrics and Child Health 46(1-2): 51-56, 2010

Oxygen outflow delivered by manually operated self-inflating resuscitation bags in patients breathing spontaneously. Jornal Brasileiro de Pneumologia 34(4): 212-216, 2008

Inadequate preoxygenation during spontaneous ventilation with single patient use self-inflating resuscitation bags. Anaesthesia and Intensive Care 34(5): 685-686, 2006

The moisture-conserving performance of breathing system filters in use with simulated circle anaesthesia breathing systems. Anaesthesia 59(3): 271-277, 2004

The self-inflating resuscitation bag delivers high oxygen concentrations when used without a reservoir: implications for neonatal resuscitation. Respiratory Care 54(12): 1665-1670, 2009

A new modular system for anaesthesia and resuscitation Remarks on the need of supplemental oxygen In resuscitation and anaesthesia under field conditions. Acta Anaesth Scand Suppl.: 14, 1966

A new modular system for anaesthesia and resuscitation AGA polyvalve A new non-rebreathing valve. Acta Anaesth Scand Suppl 26: 31-42, 1966

Severe valve deformation following cardiopulmonary resuscitation in a patient with a transcatheter aortic valve. Jacc. Cardiovascular Interventions 8(3): 498-499, 2015

Breathing Systems For Use In Anaesthesia. Bja: British Journal of Anaesthesia 60(5): 555-564, 1988

Influence of patient factors on the efficacy of breathing system filters at preventing contamination of breathing systems. Anaesthesia 65(5): 468-472, 2010

Monitoring of anaesthesia breathing systems by capnography. Anesthesie Analgesie Reanimation 36(9-10): 403-408, 1979

Hazard of self-inflating resuscitation bag. British Medical Journal 2(5761): 589, 1971

Sevoflurane degradation to compound A in anaesthesia breathing systems. British Journal of Anaesthesia 77(4): 537-543, 1996

Resuscitation, anaesthesia and analgesia of the burned patient. Current Opinion in Anaesthesiology 14(4): 431-435, 2001