Thyroid shields versus z-axis automatic tube current modulation for dose reduction at neck CT



Thyroid shields versus z-axis automatic tube current modulation for dose reduction at neck CT



Radiology 249(2): 572-580



To assess the effectiveness of in-plane bismuth thyroid shields and a z-axis automatic tube current modulation (ATCM) technique with respect to dose reduction and image noise in the thyroid and other regional tissues during neck computed tomography (CT). Because this was a phantom study, neither institutional review board approval nor HIPAA compliance was required. A female phantom, thyroid shields, and an eight-section CT scanner were used. Radiation dose was measured by using thermoluminescent dosimetry (TLD) chips placed in the phantom's thyroid, cervical bone marrow, and soft tissues. Scans were performed by using fixed tube current and a z-axis ATCM technique with and without shields. Image noise was quantified as the standard deviation of the attenuation value (in Hounsfield units) on CT images. Thyroid dose was 76.9 mGy with an unshielded fixed tube current technique. Use of shields and ATCM reduced this dose to 44.7 mGy (42% reduction, P < .001) and 17.0 mGy (78% reduction, P < .001), respectively. The combination of shields and ATCM further reduced this dose to between 11.9 and 12.9 mGy (83%-85% reduction, P < .001), depending on the shield's presence in the scout scan. ATCM resulted in minimized tube current throughout the neck, which reduced dose-length product across the entire scan volume by 60% (926 vs 368 mGy . cm). Thyroid bed noise was lowest (3.9 HU) during the fixed tube current technique without shields, with noise slightly higher (6.9 HU) with the unshielded ATCM technique (P < .001). Thyroid image noise was markedly higher when using shields (P < .001), with noise measuring between 74 and 113 HU for fixed tube current and ATCM scans. z-Axis ATCM is more effective than shields at reducing thyroid radiation dose during neck CT. Shields combined with ATCM slightly further reduces dose; however, this is associated with higher image noise.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 056579771

Download citation: RISBibTeXText

PMID: 18780826

DOI: 10.1148/radiol.2492071430


Related references

Organ-based dose current modulation and thyroid shields: techniques of radiation dose reduction for neck CT. Ajr. American Journal of Roentgenology 198(5): 1132-1138, 2012

Radiation dose savings for adult pulmonary embolus 64-MDCT using bismuth breast shields, lower peak kilovoltage, and automatic tube current modulation. Ajr. American Journal of Roentgenology 192(1): 244-253, 2009

Attenuation-based automatic tube voltage selection and tube current modulation for dose reduction at contrast-enhanced liver CT. Radiology 265(2): 437-447, 2012

Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back projection for 80-kVp abdominal CT: Anthropomorphic phantom and patient study. European Journal of Radiology 85(9): 1666-1672, 2016

Reduction of effective dose and organ dose to the eye lens in head MDCT using iterative image reconstruction and automatic tube current modulation. Biomedical Papers of the Medical Faculty of the University Palacky Olomouc Czechoslovakia 158(2): 265-272, 2014

Detection of urinary tract stones at low-radiation-dose CT with z-axis automatic tube current modulation: phantom and clinical studies. Radiology 235(2): 523-529, 2005

Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D). Plos one 10(11): E0142185, 2015

Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. Ajr. American Journal of Roentgenology 190(5): 1232-1240, 2008

Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 232(2): 347-353, 2004

Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose. Ajnr. American Journal of Neuroradiology 27(10): 2221-2225, 2006

The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging. Pediatric Radiology 43(10): 1287-1294, 2013

Potential for radiation dose savings in abdominal and chest CT using automatic tube voltage selection in combination with automatic tube current modulation. Ajr. American Journal of Roentgenology 203(2): 292-299, 2014

Bismuth shielding, organ-based tube current modulation, and global reduction of tube current for dose reduction to the eye at head CT. Radiology 262(1): 191-198, 2012

Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography. Ajnr. American Journal of Neuroradiology 30(9): 1754-1759, 2009

Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis. Acta Radiologica 52(10): 1101-1106, 2011