Trial spinal cord stimulator reimplantation following lead breakage after third birth



Trial spinal cord stimulator reimplantation following lead breakage after third birth



Pain Physician 13(6): 523-526



Many studies have reported lead migration and breakage as complications of epidural spinal cord stimulation. In cases where rapid changes in physique such as those caused by pregnancy are expected, it is unclear whether extra consideration regarding possible adjustments and care to avoid complications such as lead breakage are required. This article presents a case in which spinal cord stimulation was used to manage these complications in a woman during the perinatal period. Case report. Pain management clinic. The patient was a 36-year-old female, approximate weight of 100 pounds, and 5-foot 1 inch in height, whose chief complaint was lower back and bilateral leg pain. The pain could not be alleviated by conservative therapies such as nerve blockade, oral medications with non-steroidal anti-inflammatory drugs, antidepressants, anticonvulsants or physical therapy. A spinal cord stimulator was implanted at another facility, which relieved the pain. The patient subsequently had 2 vaginal births without any problems relating to the stimulation sites, and both infants were healthy. She experienced lead breakage after the third vaginal birth that led to the subsequent reimplantation procedure. The patient had 2 subsequent vaginal births following the initial implantation with no problems related to the stimulation sites, and both infants were healthy. At age 34, following her third vaginal birth, the stimulator became ineffective and was removed. The withdrawn lead wire was found to be broken in 2 places. A case report. Pregnancy following implantation of a spinal cord stimulator might result in lead breakage as abdominal girth increases. The present case exemplifies how pregnancy following implantation of a spinal cord stimulator might cause lead breakage as abdominal girth increases. Extra care is required to prevent lead breakage when anchors are fixed.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 056689431

Download citation: RISBibTeXText

PMID: 21102964


Related references

Spinal epidural hematoma after spinal cord stimulator trial lead placement in a patient taking aspirin. Regional Anesthesia and Pain Medicine 39(1): 70-72, 2014

Spinal cord stimulator--trial lead migration study. Pain Medicine 12(2): 204-208, 2011

Lodged spinal cord stimulator trial lead: a case report. Pain Practice 8(3): 210-213, 2008

Transcutaneous electrical nerve stimulator trial may be used as a screening tool prior to spinal cord stimulator implantation. Pain 150(2): 327-331, 2010

Lead breakage and vocal cord paralysis following blunt neck trauma in a patient with vagal nerve stimulator. Journal of the Neurological Sciences 304(1-2): 132-135, 2011

A case of an allergic reaction to a spinal cord stimulator: identification of the antigen with epicutaneous patch testing, allowing successful reimplantation. Neuromodulation 16(6): 595-599, 2013

Retrograde spinal cord stimulator lead placement for right L5 radiculopathy. Pain Medicine 13(5): 733-734, 2012

Spontaneous lead breakage in implanted spinal cord stimulation systems. Korean Journal of Pain 23(1): 78-81, 2010

Progressive Paraplegia from Spinal Cord Stimulator Lead Fibrotic Encapsulation. American Journal of Physical Medicine and Rehabilitation 95(3): E30-E33, 2016

Accidental subdural spinal cord stimulator lead placement and stimulation. Neuromodulation 14(1): 30, 2011

Refractory insomnia in a patient with spinal cord stimulator lead migration. Neuromodulation 7(4): 242-245, 2004

Significant cephalad lead migration with use of externally powered spinal cord stimulator. Bmj Case Reports 2018:, 2018

Incidence of clinically significant percutaneous spinal cord stimulator lead migration. Neuromodulation 18(2): 123, 2015

Movable contact locking mechanism for spinal cord stimulator lead connector. Official Gazette of the United States Patent and Trademark Office Patents 1282(4), 2004

Pseudomeningocele and percutaneous intrathecal lead placement complication for spinal cord stimulator. Journal of Clinical Neuroscience 59: 347-349, 2019