Vibration characteristics of dental high-speed turbines and speed-increasing handpieces



Vibration characteristics of dental high-speed turbines and speed-increasing handpieces



Journal of Dentistry 36(7): 488-493



Vibrations of dental handpieces may contribute to symptoms of hand-arm vibration syndrome in dental personnel and iatrogenic enamel cracking in teeth. However, methods for measuring dental handpiece vibrations have previously been limited and information about vibration characteristics is sparse. This preliminary study aimed to use a novel approach to assess the vibrations of unloaded high-speed handpieces in vitro. Maximum vibration displacement amplitudes of five air turbines and two speed-increasing handpieces were recorded whilst they were operated with and without a rotary cutting instrument (RCI) using a scanning laser vibrometer (SLV). RCI rotation speeds, calculated from frequency peaks, were consistent with expected values. ANOVA statistical analysis indicated significant differences in vibrations between handpiece models (p<0.01), although post hoc tests revealed that differences between most individual models were not significant (p>0.11). Operating handpieces with a RCI resulted in greater vibrations than with no RCI (p<0.01). Points on the head of the handpiece showed greater vibration displacement amplitudes than points along the body (p<0.01). Although no single measurement exceeded 4 microm for the handpieces in the current test setup (implying that these vibrations may be unlikely to cause adverse effects), this study has formed the basis for future work which will include handpiece vibration measurements whilst cutting under clinically representative loads.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 056868102

Download citation: RISBibTeXText

PMID: 18468763

DOI: 10.1016/j.jdent.2008.03.006


Related references

Dynamic measurement of the torque-speed characteristics of dental high speed air turbine handpieces. Australian Dental Journal 39(1): 33-38, 1994

On the hygienic processing of handpieces and high-speed turbines in the dental practice. Zentralblatt fuer Hygiene und Umweltmedizin 198(1): 72-83, 1995

Decontamination of dental equipment: A validation of three devices for cleaning, disinfecting, and lubricating of dental high-speed turbines and handpieces. Zentralblatt fuer Hygiene und Umweltmedizin 196(5): 437-443, 1995

Decontamination of dental equipment. A validation of three devices designed for cleaning, disinfecting, and lubricating of dental high-speed turbines and handpieces. Zentralblatt für Hygiene und Umweltmedizin 196(5): 437-443, 1995

The cooling effect of various spray systems in turbines and a high-speed angle handpieces. Deutsche Zahnarztliche Zeitschrift 40(12): 1194-1197, 1985

Vibration studies on high-speed angular handpieces. Deutsche Zahnarztliche Zeitschrift 44(1): 64-66, 1989

Noise from high-speed dental handpieces. Journal of the American Dental Association 61: 571-577, 1960

Lubricating coolants for high-speed dental handpieces. Journal of the American Dental Association 119(2): 291-295, 1989

Radiated noise from high speed dental handpieces. Dental Digest 71(9): 404-407, 1965

Maintenance and repair of high-speed dental handpieces. General Dentistry 49(6): 636-641, 2002

The performance of autoclaved high-speed dental handpieces. Journal of the American Dental Association 103(4): 584-587, 1981

Evaluation of Dental Handpieces for High Speed Operations. The Journal Of The Stomatological Society,Japan 23(3): 244-248, 1956

The rotational performance of dental high-speed handpieces. Iyo Kizai Kenkyujo Hokoku. Reports of the Institute for Medical and Dental Engineering Tokyo Medical and Dental University 15: 61-68, 1981

High-speed dental handpieces and spread of airborne infections. New York State Dental Journal 59(1): 21-23, 1993

Factors in a subjective analysis of high speed dental handpieces. Journal of Dental Research 68(SPEC ISSUE): 213, 1989