EurekaMag.com logo
+ Site Statistics
References:
47,893,527
Abstracts:
28,296,643
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on Google+Follow on Google+
Follow on LinkedInFollow on LinkedIn

+ Translate

X-ray magnetic resonance fusion modality may reduce radiation exposure and contrast dose in diagnostic cardiac catheterization of congenital heart disease


, : X-ray magnetic resonance fusion modality may reduce radiation exposure and contrast dose in diagnostic cardiac catheterization of congenital heart disease. Catheterization and Cardiovascular Interventions 84(5): 795-800

Radiation exposure in the pediatric population may increase the risk of future malignancy. Children with congenital heart disease who often undergo repeated catheterizations are at risk. One possible strategy to reduce radiation is to use X-ray Magnetic Resonance Fusion (XMRF) to facilitate cardiac catheterization. Catheterization data of patients who underwent diagnostic XMRF procedures between January 1, 2009 and February 1, 2012 were reviewed. Cases were matched 1:1 to contemporary controls who did not undergo XMRF based on weight and diagnosis and were compared in radiation exposure, contrast dose, and procedural and anesthesia times. Forty-four matched pairs were included. Baseline demographics were similar in both groups. Patients in the XMRF group had lower indices of radiation exposure measured by fluoroscopy time (14 vs. 16.4 vs. P = 0.047), dose-area product from fluoroscopy (513.2 vs. 589.1 µGy·m(2) , P = 0.042), total dose-area product (625.8 vs. 995.2 µGy·m(2) , P = 0.027), and total air kerma dose (94.5 vs. 153.8 mGy, P = 0.017). There was also a significant reduction in contrast dose (2 vs. 3.3 cc/kg, P <0.001). Procedural time tended to be shorter in the XMRF group but anesthesia time was significantly longer. Select diagnostic cardiac catheterization cases that utilized XMRF used less radiation and contrast than similar cases where XMRF was not used. Future work is needed to determine whether similar benefits can be extended to other types of diagnostic and complex interventional procedures.


Accession: 056966745

PMID: 24619541

DOI: 10.1002/ccd.25473

Submit PDF Full Text: Here


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Heathfield, E.; Hussain, T.; Qureshi, S.; Valverde, I.; Witter, T.; Douiri, A.; Bell, A.; Beerbaum, P.; Razavi, R.; Greil, G.F., 2014: Cardiovascular magnetic resonance imaging in congenital heart disease as an alternative to diagnostic invasive cardiac catheterization: a single center experience. The study aims to assess whether the increasing use of cardiovascular magnetic resonance imaging in place of diagnostic cardiac catheterization in the management of pediatric patients with congenital heart disease has had an impact on pediatric ca...

Dori, Y.; Sarmiento, M.; Glatz, A.C.; Gillespie, M.J.; Jones, V.M.; Harris, M.A.; Whitehead, K.K.; Fogel, M.A.; Rome, J.J., 2011: X-ray magnetic resonance fusion to internal markers and utility in congenital heart disease catheterization. X-ray magnetic resonance fusion (XMRF) allows for use of 3D data during cardiac catheterization. However, to date, technical requirements have limited the use of this modality in clinical practice. We report on a new internal-marker XMRF method th...

Ghelani, S.J.; Glatz, A.C.; David, S.; Leahy, R.; Hirsch, R.; Armsby, L.B.; Trucco, S.M.; Holzer, R.J.; Bergersen, L., 2015: Radiation dose benchmarks during cardiac catheterization for congenital heart disease in the United States. The aim of this study was to define age-stratified, procedure-specific benchmark radiation dose levels during interventional catheterization for congenital heart disease. There is a paucity of published literature with regard to radiation dose lev...

Kunisawa, T.; Kurosawa, A.; Oikawa, M.; Mizobuchi, M.; Hayashi, D.; Iwasaki, H., 2012: A high dose of dexmedetomidine using the BIS monitor™ for diagnostic and interventional cardiac catheterization in a toddler with congenital heart disease. Dexmedetomidine (DEX) for sedation in diagnostic and interventional cardiac catheterization (DICC) has been reported to require other drugs or rescue drugs because of its insufficient sedative effect when used alone. We administered DEX and adjust...

Hou, Q-Ru.; Gao, W.; Zhong, Y.Min.; Sun, A.Min.; Wang, Q.; Qiu, H.Sheng.; Wang, F.; Li, J.Ying.; Hu, L., 2016: A Prospective Evaluation of Contrast and Radiation Dose and Image Quality in Cardiac CT in Children with Complex Congenital Heart Disease using Low-concentration Iodinated Contrast Agent and Low Tube Voltage and Current. To assess image quality, contrast dose and radiation dose in cardiac CT in children with congenital heart disease using low-concentration iodinated contrast agent and low tube voltage and current in comparison with standard-dose protocol. 110 pati...

Yakoumakis, E.; Kostopoulou, H.; Makri, T.; Dimitriadis, A.; Georgiou, E.; Tsalafoutas, I., 2013: Estimation of radiation dose and risk to children undergoing cardiac catheterization for the treatment of a congenital heart disease using Monte Carlo simulations. Children diagnosed with congenital heart disease often undergo cardiac catheterization for their treatment, which involves the use of ionizing radiation and therefore a risk of radiation-induced cancer. The purpose of this study was to calculate t...

Heer, T.; Reiter, S.; Höfling, B.; Pilz, Günter., 2014: Diagnostic performance of non-contrast-enhanced whole-heart magnetic resonance coronary angiography in combination with adenosine stress perfusion cardiac magnetic resonance imaging. We sought to evaluate the diagnostic performance of 1.5-T non-contrast enhanced whole-heart magnetic resonance coronary angiography (MRCA) alone and in combination with adenosine stress cardiac magnetic resonance imaging (CMR-Perf). MRCA has been...

Alghamdi, M.H.; Grosse-Wortmann, L.; Ahmad, N.; Mertens, L.; Friedberg, M.K., 2012: Can simple echocardiographic measures reduce the number of cardiac magnetic resonance imaging studies to diagnose right ventricular enlargement in congenital heart disease?. Right ventricular (RV) enlargement is used as a criterion for the treatment of RV outflow tract dysfunction in patients with congenital heart disease. Although RV volumes are most accurately measured by cardiac magnetic resonance (CMR), CMR is a l...

Schulte-Brinkmann, W., 1966: Radiation exposure of patients and radiologic personnel during cardiac catheterization and contrast medium demonstration of the heart and great vessels. II. Measurement by an apparatus for a biplanar picture series in a large film size and 1 cassette changer. Exposure to dispersed radiation in the examiner with protective clothing. Strahlentherapie 129(2): 295-307