Air-Water Binary Gas Integrity Test for Sterilizing and Virus Filters



Air-Water Binary Gas Integrity Test for Sterilizing and Virus Filters



Pda Journal of Pharmaceutical Science and Technology 70(6): 577-590



Reliability of retention performance is of paramount importance for membrane filters designed for sterile and virus filtration. To achieve dependable retention, an integrity test can be applied to ensure the absence of oversize pores or defects that can compromise the retention capability of the filter. Probably the most commonly applied nondestructive integrity test for membrane filters is the gas-liquid diffusion test, with air and water often used as the gas-liquid pair. However, the sensitivity of the air-water diffusion test is limited by the fact that the diffusive flow rate for an integral membrane can span a range that is large compared to the flow contributed by a defect. A novel nondestructive air-water integrity test for microporous and nanoporous membranes is introduced here that provides improved test sensitivity by measuring the gas composition in addition to gas flow rate. Oxygen permeates through water faster than does nitrogen, so with air as the challenge gas and water as the wetting fluid, the permeate stream will be enriched in oxygen. The permeate oxygen concentration is predictable, accurately measurable, and within a narrow and repeatable range for an integral membrane. A leak through the membrane will result in a deviation from the integral permeate concentration, signaling a defect. Compared to the conventional air-water diffusion test, this air binary gas (i.e., O2 and N2) test in which the permeate gas composition is measured (in addition to the diffusive flow rate) has a superior signal-to-noise ratio and was demonstrated to provide a significantly higher level of retention assurance for both sterilizing grade and virus filters. Because air and water are used as the gas-liquid pair, the air binary gas test also maintains the convenience, safety, and environmentally friendly aspects of the air-water diffusion test. To ensure that sterilizing and virus removal filters are free of defects, an integrity test is often conducted both before and after use of the filters. In the commonly used air-water diffusion integrity test, pressurized air is applied to the water wetted filter and the air flow rate across the filter is measured. A flow rate above a specified limit indicates a leak through the filter. The sensitivity of the test is limited by the level of background noise (integral flow rate) relative to the leak signal (excess flow rate). An enhancement to the air-water diffusion test is introduced here in which the sensitivity of the test can be improved by measuring the composition of the diffused gas. Oxygen permeates through water faster than does nitrogen, so the permeating gas will be enriched in oxygen. Compared to the flow rate, which can span a range of values for integral filters, the integral oxygen concentration is well defined, so even small deviations from the expected concentration signal a leak. Because air and water are used as the test materials, the developed approach achieved higher sensitivity without sacrificing the convenience, safety, and environmentally friendly aspects of the air-water diffusion test.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 057155893

Download citation: RISBibTeXText

PMID: 27789800

DOI: 10.5731/pdajpst.2016.006437


Related references

An assessment of test criteria for evaluating the performance and integrity of sterilizing filters. Bulletin of the Parenteral Drug Association 31(4): 187-194, 1977

The Water Pressure Integrity Test--a new integrity test for hydrophobic membrane filters. Journal of Parenteral Science and Technology 46(4): 102-106, 1992

Pre-use/Post-sterilization Integrity Testing of Sterilizing Grade Filters. Pda Journal of Pharmaceutical Science and Technology 66(5): 394-395, 2016

Product-wet integrity testing of sterilizing grade filters--points to consider. Pda Journal of Pharmaceutical Science and Technology 62(5): 313-317, 2008

Accuracy of automated instruments used in the pharmaceutical industry for integrity testing sterilizing filters. Pda Journal of Pharmaceutical Science and Technology 57(4): 277-286, 2003

A method for checking the integrity and quality of membrane filters for sterilizing nutrient culture media. Meditsinskaia Parazitologiia i Parazitarnye Bolezni: 67-68, 1989

Methods for controlling the integrity of membrane filters for the sterilizing filtration of liquids in the production of injectable solutions a review. Khimiko-Farmatsevticheskii Zhurnal 24(2): 166-170, 1990

Use of pressure-hold test for sterilizing filter membrane integrity in radiopharmaceutical manufacturing. Nuclear Medicine and Biology 36(8): 955-959, 2010

Penetration of conventional sterilizing grade filters by diminutive water-borne organisms. Abstracts of the General Meeting of the American Society for Microbiology 99: 560, 1999

Rationalization and valid scale-up of integrity test parameters for sterilizing grade membrane filter cartridges. Pda Journal of Pharmaceutical Science and Technology 55(2): 134-142, 2001

Evaluation of recovery filters for use in bacterial retention testing of sterilizing-grade filters. Pda Journal of Pharmaceutical Science and Technology 50(3): 147-153, 1996

A nondestructive integrity test for membrane filters based on air-coupled ultrasonic spectroscopy. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 50(6): 676-685, 2003

Geometric approach for designing optical binary amplitude and binary phase-only filters. Applied Optics 37(35): 8233-8246, 2008

Smoothing of the edge-enhanced impulse response from binary phase-only filters using random binary patterns. Applied Optics 28(15): 2987-2988, 1989

Integrity testing of Planova™ BioEX virus removal filters used in the manufacture of biological products. Biologicals 43(3): 186-194, 2016