+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Assessment Of Diagnostic Multileaf Collimator For Cephalometric Exposure Reduction Using Optically Stimulated Luminescent Dosemeters



Assessment Of Diagnostic Multileaf Collimator For Cephalometric Exposure Reduction Using Optically Stimulated Luminescent Dosemeters



Radiation Protection Dosimetry (): -



NlmCategory="UNASSIGNED">A diagnostic multileaf collimator (MLC) was developed for diagnostic radiography dose reduction. Optically stimulated luminescent dosemeters (OSLDs) were used to evaluate the efficacy of this device for dental radiography cephalometric exposure reduction. The OSLD dosimetric characteristics for 80 kVp cephalometric exposure were first obtained. The batch homogeneity and reproducibility were 1.67 % and 0.18-1.58, respectively. Good linearity was obtained between the OSLD dose and response, and the angular dependence was within ±4 %. The equivalent organ doses for the left eye, right eye and thyroid were 41.20±6.58, 178.86±1.71 and 171.12±8.78 μSv and 36.80±0.33, 156.63±0.22 and 22.04±0.13 μSv for the open and MLC fields, respectively. The MLC-induced dose reductions for the left and right eyes of in field were 10.67±16.78 and 12.42±8.84 %, respectively, and that of the thyroid gland of out of field was 87±8.82 %, considering combined uncertainty. Therefore, use of diagnostic MLC for dose reduction during dental radiography cephalometric exposure is both feasible and effective.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 057240275

Download citation: RISBibTeXText

PMID: 27056147

DOI: 10.1093/rpd/ncw080


Related references

Characterisation of energy response of Al(2)O(3):C optically stimulated luminescent dosemeters (OSLDs) using cavity theory. Radiation Protection Dosimetry 153(1): 23-31, 2013

Evaluation of personal dose equivalent using optically stimulated luminescent dosemeters in Marumori after the Fukushima nuclear accident. Radiation Protection Dosimetry 154(3): 385-390, 2013

Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology. Dento Maxillo Facial Radiology 41(3): 211-216, 2012

Independent evaluation of optically stimulated luminescence (OSL) 'dot' dosemeters for environmental monitoring. Radiation Protection Dosimetry 143(1): 27-32, 2011

Treatment time reduction through multileaf collimator leaf-sequencing in static IMRT. International Journal of Radiation Oncology Biology Physics 48(3 Supplement): 340-341, 2000

Field margin reduction using intensity-modulated x-ray beams formed with a multileaf collimator. International Journal Of Radiation Oncology Biology Physics. 38(5): 1123-1129, 1997

Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations. Medical Physics 33(4): 1125-1132, 2006

Effects of collimator jaw setting on dose output for treatments with multileaf collimator. Medical Dosimetry 23(4): 296-298, 1998

Dosimetric comparison of an integrated multileaf-collimator versus a conventional collimator. Physics in Medicine and Biology 42(11): 2285-2303, 1997

Comparison of a micro-multileaf collimator with a 5-mm-leaf-width collimator for intracranial stereotactic radiotherapy. International Journal of Radiation Oncology, Biology, Physics 57(5): 1443-1449, 2003

Volumetric modulated arc therapy with dynamic collimator rotation for improved multileaf collimator tracking of the prostate. RadioTherapy and Oncology, 2016

Variable circular collimator in robotic radiosurgery: a time-efficient alternative to a mini-multileaf collimator?. International Journal of Radiation Oncology, Biology, Physics 81(3): 863-870, 2011

Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence. Radiation Protection Dosimetry 140(3): 294-299, 2010

Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors. Medical Physics 37(10): 5541-5549, 2010

Collimator based tracking with an add-on multileaf collimator: Moduleaf. Physics in Medicine and Biology 60(8): 3257-3269, 2015