+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

CT-guided Native Medical Renal Biopsy: Cortical Tangential versus Non-Tangential Approaches-A Comparison of Efficacy and Safety



CT-guided Native Medical Renal Biopsy: Cortical Tangential versus Non-Tangential Approaches-A Comparison of Efficacy and Safety



Radiology 283(1): 293-299



Purpose To review a single-center experience with the cortical tangential approach during computed tomography (CT)-guided native medical renal biopsy and to evaluate its efficacy and safety compared with those of a non-cortical tangential approach. Materials and Methods This retrospective study received institutional review board approval, with a waiver of the HIPAA requirement for informed consent. The number of cores, glomeruli, and complications were reviewed in 431 CT-guided medical renal biopsies performed between July 2007 and September 2015. A biopsy followed a cortical tangential approach if the needle path was parallel to the renal cortical surface, at a depth closer to the renal capsule than the renal pelvic fat. A sample was considered adequate if the biopsy yielded at least 10 glomeruli at light microscopy, one glomerulus at immunofluorescence microscopy, and one glomerulus at electron microscopy. The χ2 test, the t test, the Mann-Whitney test, and logistic regression modeling of sample adequacy were performed. Results One hundred fifty-six (36%) of 431 biopsies were performed with the cortical tangential approach. More cores were obtained for the cortical tangential group (2.6 vs 2.4, P = .001); biopsy needle gauge was not significantly different (P = .076). More adequate samples were obtained in the cortical tangential group (66.7% vs 49.8%, P = .001), with more glomeruli (23 vs 16, P = .014). Results were significant after controlling for needle gauge and number of cores (P = .008). The cortical tangential group had fewer complications (1.9% vs 7.3%, P = .018). Conclusion The cortical tangential approach, when applied to CT-guided native medical renal biopsies, results in higher rates of sample adequacy and lower rates of postprocedural complications. © RSNA, 2016.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 057339995

Download citation: RISBibTeXText

PMID: 27875104

DOI: 10.1148/radiol.2016160912


Related references

US-guided renal transplant biopsy: efficacy of a cortical tangential approach. Radiology 256(1): 290-296, 2010

Real time ultrasound guided pediatric percutaneous renal biopsy: the traditional method versus angled tangential approach. Jbr-Btr 97(4): 206-210, 2015

Tangential beam IMRT versus tangential beam 3D-CRT of the chest wall in postmastectomy breast cancer patients: a dosimetric comparison. Radiation Oncology 6: 26, 2011

A modified technique for real time ultrasound guided pediatric percutaneous renal biopsy: the angled tangential approach. Quantitative Imaging in Medicine and Surgery 4(3): 190-194, 2014

Dosimetric evaluation of intensity-modulated tangential beam versus conventional tangential irradiation for breast cancer. Ai Zheng 25(7): 855-860, 2006

In vivo surface dose measurement using GafChromic film dosimetry in breast cancer radiotherapy: comparison of 7-field IMRT, tangential IMRT and tangential 3D-CRT. Radiation Oncology 9: 156, 2015

Efficacy and safety of ultrasound (US) guided percutaneous needle biopsy for peripheral lung or pleural lesion: comparison with computed tomography (CT) guided needle biopsy. Journal of Thoracic Disease 11(3): 936-943, 2019

Real-time ultrasound-guided renal biopsy with a biopsy gun in children: Safety and efficacy. Acta Paediatrica 90(12): 1394-1397, 2001

Tangential Biopsy Thickness versus Lesion Depth in Longitudinal Melanonychia: A Pilot Study. Dermatology Research and Practice 2012: 353864, 2012

Tangential Extraperitoneal Retrorenal approach: a specified uniform technique for renal transplant biopsy. Transplant International 30(9): 947-950, 2017

Percutaneous real-time ultrasound-guided renal biopsy with automated biopsy gun in paediatrics Complications, safety and efficacy. Journal of the American Society of Nephrology 14(Abstracts Issue): 299A, 2003

Comparison of the efficacy and safety of ultrasound-guided core needle biopsy versus fine-needle aspiration for evaluating thyroid nodules. Endocrine Practice 21(2): 128-135, 2016

Yield and complications in percutaneous renal biopsy. A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys. Acta Radiologica 38(3): 431-436, 1997

Comparison of microbial removal between slow dead-end versus tangential sand filtration. Water Environment Research, 2018

Comparison of Microbial Removal Between Slow Dead-End Versus Tangential Sand Filtration. Water Environment Research 90(7): 589-597, 2018