Effect on inspiratory cycling-off synchronization with different expiratory trigger sensitivity level during pressure-support ventilation: a lung model study



Effect on inspiratory cycling-off synchronization with different expiratory trigger sensitivity level during pressure-support ventilation: a lung model study



Zhonghua Yi Xue Za Zhi 94(38): 2977-2981



To compare the inspiratory cycling-off synchronization with different expiratory trigger sensitivity (ETS) setting during noninvasive pressure support ventilation (PSV) under the conditions of system leak. Ventilators were connected to a lung model (Hans Rudolph Series1101 simulator). And its mechanics was set in two models of obstructive and restrictive ventilatory dysfunction. All ventilators were set at 15 cmH2O (1 cmH2O = 0.098 kPa) pressure support and 5 cmH2O positive end-expiratory pressure (PEEP). Tests were conducted at the level of air leaks (24-28 L/min). Cycling delay time, tidal volume and airflow were collected. Compared with Curative Flexo ST 30 with the ETS setting at the most sensitive level, the use of digital Auto-Trak(TM) system (Respironics Synchrony) was associated with milder delay cycling ((68.9 ± 13.3) vs (121.4 ± 13.2) ms, P < 0.05) in obstructive condition. The tidal volume (VT), inspiratory time (TI vent) and peak expiratory flow (PEF) increased after adjusting the ETS level. Premature cycling was detected in restrictive condition with both ventilators. Peak inspiratory flow (PIF) and PEF significantly increased as VT and TI vent decreased. Delay cycling ((64.3 ± 15.3) ms) was present in Flexo ST 30 when ETS was at most insensitive level. There are significant differences in performances and cycling-off in obstructive and restrictive conditions among 2 bilevel ventilators. And it may be due to the software of algorithm. Modifications of ETS can affect the ventilatory parameters to improve patient-ventilator synchrony in the presence of air leaks. The Auto-Trak system during PSV show similar results and better synchronzation compared with conventional adjustments.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 057712779

Download citation: RISBibTeXText

PMID: 25547698


Related references

Automation of expiratory trigger sensitivity in pressure support ventilation. Respiratory Care Clinics of North America 7(3): 503-17, X, 2001

Effect of different inspiratory rise time and cycling off criteria during pressure support ventilation in patients recovering from acute lung injury. Critical Care Medicine 31(11): 2604-2610, 2003

Relationships between sensitivity of the expiratory trigger and breathing pattern during pressure support ventilation. American Review of Respiratory Disease 139(4 PART 2): A361, 1989

Effect of inspiratory synchronization during pressure-controlled ventilation on lung distension and inspiratory effort. Annals of Intensive Care 7(1): 100, 2017

Expiratory trigger setting in pressure support ventilation: from mathematical model to bedside. Critical Care Medicine 32(9): 1844-1850, 2004

Effects of inspiratory rise time on triggering work load during pressure-support ventilation: a lung model study. Respiratory Care 55(7): 878-884, 2010

Effects of pressure support ventilation on ventilator-induced lung injury in mild acute respiratory distress syndrome depend on level of positive end-expiratory pressure: A randomised animal study. European Journal of Anaesthesiology 35(4): 298-306, 2018

Effect of different cycling-off criteria and positive end-expiratory pressure during pressure support ventilation in patients with chronic obstructive pulmonary disease. Critical Care Medicine 35(11): 2547-2552, 2007

Effect of Trigger Sensitivity on Redistribution of Ventilation During Pressure Support Ventilation Detected by Electrical Impedance Tomography. Anesthesiology and Pain Medicine 5(4): E27439, 2015

Effect of expiratory trigger sensitivity ets of efficacy of pressure support in acute respiratory failure. American Review of Respiratory Disease 143(4 PART 2): A690, 1991

The effect of independent variations in inspiratory-expiratory ratio and end expiratory pressure during mechanical ventilation in hyaline membrane disease: the significance of mean airway pressure. Journal of Pediatrics 91(5): 794-798, 1977

Setting individualized positive end-expiratory pressure level with a positive end-expiratory pressure decrement trial after a recruitment maneuver improves oxygenation and lung mechanics during one-lung ventilation. Anesthesia and Analgesia 118(3): 657-665, 2014

The effects of inspiratory to expiratory ratio on ventilation and oxygenation during high frequency partial liquid ventilation in a rabbit model of acute lung injury. Korean Journal of Anesthesiology 57(2): 203-209, 2019

Patient-ventilator interactions during partial ventilatory support: a preliminary study comparing the effects of adaptive support ventilation with synchronized intermittent mandatory ventilation plus inspiratory pressure support. Critical Care Medicine 30(4): 801-807, 2002

Effectiveness of Inspiratory Termination Synchrony with Automatic Cycling During Noninvasive Pressure Support Ventilation. Medical Science Monitor 22: 1694-1701, 2017