Influence of reagent storage in Sysmex CA7000 for different time on 4 test RESULTS: of the plasma coagulation



Influence of reagent storage in Sysmex CA7000 for different time on 4 test RESULTS: of the plasma coagulation



Zhongguo Shi Yan Xue Ye Xue Za Zhi 22(6): 1721-1727



The purpose of this study was to investigate the influence of blood coagulation reagents stored for different time on test results of the specimens prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT) and fibrinogen (Fib). A total of 21 patient plasma specimens was taken and measured for homeostasis by Sysmex CA7000 automated blood coagulation analyzer and supporting reagent. The PT, APTT, TT and Fib of specimens were measured with the reagents stored in Sysmex CA7000 for different time. The differences of PT, APTT, TT and Fib were analyzed between values measured of the reagents stored for 0 hour and different time (TS:12, 24, 36,48, 60, 72 h; DA:24, 48, 72, 96, 120 h; TT:2, 4, 6, 8, 10, 12 h; TR:4, 8, 12, 16, 20, 24 h; OVB:1, 2, 3, 4, 5 ,6 h), respectively. The results showed that when coagulation reagent TS were stored for more than 48 h , DA 96 h, TT 10 h, TR 16 h and OVB 4 h, the values of PT, APTT, TT and Fib of samples were statistically different from the values measured with fresh coagulation reagent (P < 0.01), respectively. Compared 0 h with TS stored for 48-72, DA 96-120, TT 10-12, TR 16-24 and OVB 4-6 h, the percentage difference of PT, APTT, TT and Fib is in -2.6% ∼ 10.8%, -3.44% ∼ 4.8%, -3.9% ∼ 5.52%, -10.8% ∼ 3.3% and -17.2% ∼ 0.5%, the PT and Fib changes were more significant. Accordingly, the result of PT, APTT and TT had a uptrend as the reagent stored in Sysmex CA7000 analyzer for a long time, while Fib downtrend. It is concluded that the reagents showed be timely replaced when the plasma coagulation test is performed so as to obtain accurate results of examination.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 058113629

Download citation: RISBibTeXText

PMID: 25543504


Related references

Coagulation factors V, VIII, and X, prothrombin time and activated partial thromboplastin time test results in thawed plasma stored at 1-6 ºC for 5 days. Blood Transfusion 9(1): 95-98, 2011

Influence of transportation and storage of plasma and blood on the results of blood coagulation tests. Annals of Hematology 76(Suppl. 1): A49, 1998

PH of water, muscle type and storage time influence on boiling test results. Medycyna Weterynaryjna 54(7): 494-496, 1998

Influence of pre-analytical storage conditions on four plasma coagulation molecular markers measured using a STACIA automatic coagulation analyzer. Rinsho Byori. Japanese Journal of Clinical Pathology 60(12): 1139-1144, 2012

The influence of time of storage, temperature of storage, platelet number in platelet-rich plasma, packed cell, mean platelet volume, hemoglobin concentration, age, and sex on platelet aggregation test. Annals of Hematology 71(3): 129-133, 1995

Effect of adverse storage conditions of antigen reagent on performance of the rapid plasma reagin test. International Journal of STD and AIDS 12(5): 299-301, 2001

Prothrombin time and APTT dilution test A simple and useful test for the diagnosis of coagulation plasma factor deficiencies. Blood 88(10 Suppl. 1 Part 1-2): 69B, 1996

Revisiting fresh frozen plasma transfusion guidelines Correlation of prothrombin time with individual coagulation factor levels in reagent dependent. Blood 86(10 Suppl. 1): 355A, 1995

Multicenter evaluation of a bilayer polymer blood collection tube for coagulation testing: effect on routine hemostasis test results and on plasma levels of coagulation activation markers. Blood Coagulation and Fibrinolysis 17(8): 625-631, 2006

The influence of storage on the coagulation factors of human plasma. Australian Jour Exptl Biol And Med Sci 26(3): 207-213, 1948

Influence of reagent and lot to lot variation on the reproducibility and accuracy of the ca 19 9 ca 15 3 test results. Journal of Tumor Marker Oncology 5(3): 225, 1990

Haemophilia patients exhibit prolonged coagulation time but normal lag time of thrombin generation test: are these results really discordant?. Thrombosis and Haemostasis 97(4): 675-676, 2007

Effects of Different Storage Time and Temperature on Coagulation Function of Fresh Frozen Plasma after Thawing. Zhongguo Shi Yan Xue Ye Xue Za Zhi 25(3): 911-915, 2017

The plasma coagulation time as a simple test for vitamin K deficiency. Amer Jour Med Sci 200(3): 327-337, 1940

Evaluation of performance including influence by interfering substances of the Innovance D-dimer assay on the Sysmex coagulation analyzer. Annals of Clinical and Laboratory Science 41(1): 20-24, 2011