Peak flow velocities in the ascending aorta-real-time phase-contrast magnetic resonance imaging vs. cine magnetic resonance imaging and echocardiography



Peak flow velocities in the ascending aorta-real-time phase-contrast magnetic resonance imaging vs. cine magnetic resonance imaging and echocardiography



Quantitative Imaging in Medicine and Surgery 5(5): 685-690



This prospective study of eight healthy volunteers evaluates peak flow velocities (PFV) in the ascending aorta using real-time phase-contrast magnetic resonance imaging (MRI) in comparison to cine phase-contrast MRI and echocardiography. Flow measurements by echocardiography and cine phase-contrast MRI with breath-holding were performed according to clinical standards. Real-time phase-contrast MRI at 40 ms temporal resolution and 1.3 mm in-plane resolution was based on highly undersampled radial fast low-angle shot (FLASH) sequences with image reconstruction by regularized nonlinear inversion (NLINV). Evaluations focused on the determination of PFV. Linear regressions and Bland-Altman plots were used for comparisons of methods. When averaged across subjects, real-time phase-contrast MRI resulted in PFV of 120±20 cm s(-1) (mean ± SD) in comparison to 122±16 cm s(-1) for cine MRI and 124±20 cm s(-1) for echocardiography. The maximum deviations between real-time phase-contrast MRI and echocardiography ranged from -20 to +14 cm s(-1) (cine MRI: -10 to +12 cm s(-1)). Thus, in general, real-time phase-contrast MRI of cardiac outflow revealed quantitative agreement with cine MRI and echocardiography. The advantages of real-time MRI are measurements during free breathing and access to individual cardiac cycles.

(PDF emailed within 0-6 h: $19.90)

Accession: 058518275

Download citation: RISBibTeXText

PMID: 26682138

DOI: 10.3978/j.issn.2223-4292.2015.08.08


Related references

Optimal individual inversion time in brain arterial spin labeling perfusion magnetic resonance imaging: correlation with carotid hemodynamics measured with cine phase-contrast magnetic resonance imaging. Journal of Computer Assisted Tomography 37(2): 247-251, 2013

In vivo quantification of helical blood flow in human aorta by time-resolved three-dimensional cine phase contrast magnetic resonance imaging. Annals of Biomedical Engineering 37(3): 516-531, 2009

4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography. Pediatric Radiology 45(6): 804-813, 2016

Time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI) reveals altered blood flow patterns in the ascending aorta of patients with valve-sparing aortic root replacement. Journal of Thoracic and Cardiovascular Surgery 2019, 2019

Accuracy of right and left ventricular functional assessment by short-axis vs axial cine steady-state free-precession magnetic resonance imaging: intrapatient correlation with main pulmonary artery and ascending aorta phase-contrast flow measurements. Canadian Association of Radiologists Journal 64(3): 213-219, 2013

Magnetic resonance real time imaging of left ventricular function Comparison with conventional magnetic resonance imaging and echocardiography. Journal of the American College of Cardiology 35(2 suppl A): 427A-428A, 2000

Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography. American Journal of Cardiology 87(1): 95-99, 2001

Determination of renal blood flow rbf by phase contrast cine magnetic resonance imaging p c cine mri. Journal of the American Society of Nephrology 2(3): 491, 1991

Magnetic resonance imaging evaluation of the ascending aorta after graft-inclusion surgery: comparison between an ultrafast contrast-enhanced MR sequence and conventional cine-MRI. Journal of Magnetic Resonance Imaging 6(3): 478-483, 1996

Improved diagnostic accuracy with multiparametric magnetic resonance imaging of the breast using dynamic contrast-enhanced magnetic resonance imaging, diffusion-weighted imaging, and 3-dimensional proton magnetic resonance spectroscopic imaging. Investigative Radiology 49(6): 421-430, 2015

Real-time phase-contrast flow cardiovascular magnetic resonance with low-rank modeling and parallel imaging. Journal of Cardiovascular Magnetic Resonance 19(1): 19, 2017

Ciné phase-contrast magnetic resonance imaging for the measurement of renal blood flow. Contributions to Nephrology 165: 329-336, 2010

Value of t2-weighted magnetic resonance imaging early after myocardial infarction in dogs: comparison with bis-gadolinium-mesoporphyrin enhanced T1-weighted magnetic resonance imaging and functional data from cine magnetic resonance imaging. Investigative Radiology 37(2): 77-85, 2002

Magnetic resonance real time imaging of left ventricular function Comparison with conventional magnetic resonance techniques and echocardiography. European Heart Journal 20(ABSTR SUPPL ): 264, 1999

Normal renal blood flow measurement using phase contrast cine magnetic resonance imaging. Investigative Radiology 27(6): 465-470, 1992