+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer



Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer



Magnetic Resonance Imaging 33(4): 363-373



The purpose of this work was to evaluate different magnetization preparation and readout sequences for modified Look-Locker inversion recovery (MOLLI) toward improved T1 mapping in the heart. Elements investigated include: catalyzation sequences to prepare the magnetization before readout, alternate k-space trajectories, a spoiled gradient recalled echo readout, and a 5b(3b)3b MOLLI sampling scheme ('b' denoting beats). Conventional 3b(3b)3b(3b)5b MOLLI with a linear k-space trajectory was compared to four variants in simulations, in vitro and in vivo (at 3T). Variants were centric conventional MOLLI, centric-paired conventional MOLLI, linear 5b(3b)3b MOLLI and spoiled gradient recalled echo MOLLI. Each of these was applied with three magnetization catalyzation methods, and T1 measurement accuracy and precision were evaluated in simulations via a Monte Carlo algorithm, in a set of calibrated phantoms, and in ten healthy volunteers. Contrast-to-noise, heart rate dependence and B1+ dependence were also evaluated. A linear k-space trajectory was superior in vitro to centric and centric-paired trajectories. Of the catalyzation methods, preparation of transverse magnetization only-using a linearly increasing flip angle catalyzation-improved MOLLI T1 measurement accuracy, precision, and map quality versus methods that include catalyzation of the longitudinal magnetization. The 5b(3b)3b MOLLI scheme offered comparable native T1 measurement accuracy and precision to conventional MOLLI, despite its shortened acquisition. MOLLI T1 measurement accuracy, precision, and map quality depend on the method of catalyzation of magnetization prior to image acquisition, as well as on the readout method and MOLLI sampling scheme used.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 058820320

Download citation: RISBibTeXText

PMID: 25660643

DOI: 10.1016/j.mri.2015.02.004


Related references

Inversion group (IG) fitting: A new T1 mapping method for modified look-locker inversion recovery (MOLLI) that allows arbitrary inversion groupings and rest periods (including no rest period). Magnetic Resonance in Medicine 75(6): 2332-2340, 2015

Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magnetic Resonance in Medicine 52(1): 141-146, 2004

Improved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice. Plos One 12(11): E0187621-E0187621, 2017

Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. Journal of Cardiovascular Magnetic Resonance 12(): 69-69, 2011

Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners. Journal of Cardiovascular Magnetic Resonance 15(): 64-64, 2013

Influence of fat on liver T1 measurements using modified Look-Locker inversion recovery (MOLLI) methods at 3T. Journal of Magnetic Resonance Imaging 44(1): 105-111, 2016

Accuracy, precision, and reproducibility of myocardial T1 mapping: A comparison of four T1 estimation algorithms for modified look-locker inversion recovery (MOLLI). Magnetic Resonance in Medicine (): -, 2016

Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart. Journal of Magnetic Resonance Imaging 26(4): 1081-1086, 2007

Evaluation of Modified Look-Locker Inversion Recovery and Arrhythmia-Insensitive Rapid Cardiac T1 Mapping Pulse Sequences in Cardiomyopathy Patients. Journal of Computer Assisted Tomography, 2018

Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging. European Radiology 26(6): 1775-1782, 2015

Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: application to fluid-attenuated inversion-recovery and double inversion-recovery sequences. Magnetic Resonance in Medicine 54(1): 241-245, 2005

Impact of incidental magnetization transfer effects on inversion-recovery sequences that use a fast spin-echo readout. Magnetic Resonance in Medicine 58(4): 825-829, 2007

Consideration of slice profiles in inversion recovery Look-Locker relaxation parameter mapping. Magnetic Resonance Imaging 32(8): 1021-1030, 2015

Temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ): Dynamic myocardial T 1 mapping using a cine steady-state look-locker approach. Magnetic Resonance in Medicine, 2017

Assessment of diffuse myocardial fibrosis in rats using small-animal Look-Locker inversion recovery T1 mapping. Circulation. Cardiovascular Imaging 4(6): 636-640, 2012