Small left atrial size complicating percutaneous transcatheter device closure of secundum atrial septal defect with conventional approach



Small left atrial size complicating percutaneous transcatheter device closure of secundum atrial septal defect with conventional approach



Korean Circulation Journal 45(3): 216-224



Transcatheter device closure becomes the first option for treating secundum atrial septal defect (ASD), but the conventional method is sometimes unsuccessful even when the defect size indicates the closure to be feasible. To increase the success rate, modified methods have been introduced and used. This study aimed to find predictors for using the modified methods in the device closure of secundum ASDs. Between October 2010 and December 2012, 92 patients with ASDs underwent the transcatheter device closure. We analyzed the sizes of the defect, the surrounding rims, and the ratios of the left atrium (LA) dimensions to the device size in the patients who underwent the procedure either using the conventional or modified methods. Among the 88 successful cases (95.7%), 22 patients (25%) required modified methods (12 using pulmonary vein and 10 using balloon). The modified method group had the larger size of ASDs and smaller posterosuperior rim. The mean ratios of the LA anteroposterior diameter, width, and length to the device size were all significantly smaller in the modified methods group than in the conventional group (1.20 vs. 1.56, 1.32 vs. 1.71, and 1.61 vs. 2.07, respectively). We found that the risk factors for the modified methods were smaller retroaortic rim, larger ASD, and smaller LA dimension/device size. In addition to larger defects and smaller retroaortic rim, the smaller ratios of the LA dimensions to the device size influenced the need for the application of modified methods in the transcatheter device closure of ASDs.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 058868255

Download citation: RISBibTeXText

PMID: 26023310

DOI: 10.4070/kcj.2015.45.3.216


Related references

Percutaneous transcatheter atrial septal defect closure with Amplatzer septal occluder device using three different techniques in three adult patients with complex ostium secundum type atrial defects. Turk Kardiyoloji Dernegi Arsivi 41(2): 148-153, 2015

Experience with large ostium secundum atrial septal defect (ASD) closure by transcatheter percutaneous device (device) at J.J.Hospital. Indian Heart Journal 66: S51-S52, 2014

Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder. Journal of the Medical Association of Thailand 96(9): 1127-1134, 2013

Transcatheter closure of multi-fenestrated atrial septal aneurysm mimiking a secundum atrial septal defect Correct diagnosis and device selection by intracardiac echocardiography. European Heart Journal 24(Abstract Suppl.): 97, August-September, 2003

Assessment of right atrial and right ventricular size in children after percutaneous closure of secundum atrial septal defect with Amplatzer septal occluder. Archives of Medical Science 6(4): 567-572, 2010

Rapid normalization following percutaneous secundum atrial septal defect device closure. A study using THE RELATIVE ATRIAL INDEX. 2007

Percutaneous transcatheter closure for secundum atrial septal defect. Hunan Yi Ke Da Xue Xue Bao 28(6): 635-637, 2005

Transcatheter closure of secundum atrial septal defect with atrial septal defect occlusion system (ASDOS): initial experience and short-term follow-up. Indian Heart Journal 50(4): 409-413, 1998

Clinical application of Amplatzer septal occluder device for transcatheter closure of secundum atrial septal defect: A report of 60 cases. Zhonghua Zhongliu Zazhi 28(2): 87-92, 2000

Effectiveness of the Amplatzer device for transcatheter closure of an ostium secundum atrial septal defect. Arquivos Brasileiros de Cardiologia 88(4): 384-389, 2007

Give the patient another chance: peratrial device closure of a secundum atrial septal defect that failed percutaneous device closure. Journal of Thoracic and Cardiovascular Surgery 137(4): 1024-1027, 2009

Intracardiac echocardiography in the diagnosis and transcatheter closure of secundum atrial septal defect Effectiveness of a mathematical model for defect and device sizing. European Heart Journal 24(Abstract Suppl.): 99, August-September, 2003

Amplatzer device closure of an inferior venosus atrial septal defect after surgical closure of a secundum atrial septal defect. Images in Paediatric Cardiology 6(2): 12-17, 2004

Transcatheter closure of secundum atrial septal defects with the atrial septal defect occlusion system (ASDOS): initial experience in children. Heart 75(1): 83-88, 1996

Left atrial appendage closure using Amulet device in a patient with prior percutaneous atrial septal defect closure. Turk Kardiyoloji Dernegi Arsivi 46(4): 306-308, 2018