Sonicating multi-lumen sliced catheter tips after the roll-plate technique improves the detection of catheter colonization in adults



Sonicating multi-lumen sliced catheter tips after the roll-plate technique improves the detection of catheter colonization in adults



Journal of Microbiological Methods 122: 20-22



The Maki technique is the standard method for detecting catheter tip (CT) colonization. However, some "multi-lumen" catheters finish in a vaulted fornix and end at different distances from the CT. Therefore, we compared the traditional Maki technique with the sonication method using several cross-cut fragments of the CT. Our objective was to assess the yield of the Maki technique followed by sonication in the detection of adult CT colonization and catheter-related bloodstream infection (C-RBSI). For 3 months, we prospectively performed CT cultures of polyurethane catheters from adult patients admitted to our institution. First, we performed CT culture using the Maki technique on blood agar plates and then sonicated small fragments of CTs in 5 ml of BHI followed by culture of 100 μl of the sonicate. We included a total of 252 CVCs, with overall colonization and C-RBSI rates of 14.3% (36/252) and 5.9% (15/252). Of the 36 colonized CVCs, 21 (58.3%) were detected both by Maki and sonication, 6 (16.7%) were detected only by Maki technique, and 9 (25.0%) only by sonication method. Among 15 episodes with concomitant bacteremia, both techniques were positive and concordant in 9 cases (60.0%), the result of the Maki was positive in only 1 (6.7%), and sonication in 5 (33.3%). Our study shows that both techniques are complementary. We recommend sonicating fragments of the CT from patients with bacteremia of unknown origin and a negative CT culture by the Maki technique.

(PDF emailed within 0-6 h: $19.90)

Accession: 058879306

Download citation: RISBibTeXText

PMID: 26778418

DOI: 10.1016/j.mimet.2016.01.004



Related references

Slicing silicone neonatal vascular catheter tips improves colonization detection by the roll-plate technique. Clinical Microbiology and Infection 23(6): 410.E1-410.E3, 2017

TCT-155 A Novel Multi Lumen Compliant Balloon Catheter (ND Infusion Catheter) Preserves Stem Cell Viability and Improves Dispersion When Compared to a Standard Single Lumen Balloon Angioplasty Catheter. Journal of the American College of Cardiology 64(11): B46-B47, 2014

Diagnosis of central-venous catheter related infection with the roll-plate technique Does catheter length matter?. Abstracts of the Interscience Conference on Antimicrobial Agents & Chemotherapy 43: 344-345, 2003

Diagnosis of triple-lumen catheter infection: comparison of roll plate, sonication, and flushing methodologies. Journal of Clinical Microbiology 35(3): 641-646, 1997

Culturing triple lumen catheter tips is an insensitive method for diagnosing catheter infection. Anesthesiology (Hagerstown) 77(3A): A323, 1992

Influence of protective measures after epidural catheter disconnection on catheter lumen colonization: an in vitro study. Journal of Hospital Infection 86(2): 133-137, 2014

Incidence of colonization of central venous catheter and arterial catheter tips in a paediatric intensive care unit. Journal of Hospital Infection 96(3): 229-231, 2017

New Mahurkar triple lumen catheter , offering a 3rd lumen for inter-treatment use, is comparable to the marketed double lumen catheter Y. Journal of the American Society of Nephrology 12(Program and Abstract Issue): 286A, September, 2001

Double-lumen catheter assessment of aortic stenosis: comparison with separate catheter technique. Catheterization and Cardiovascular Diagnosis 29(2): 157-160, 1993

Is central venous catheter tips' colonization with multi-drug resistant Acinetobacter baumannii a predictor for bacteremia?. Clinical Infectious Diseases 52(8): 1080-1082, 2011

Diagnosis of central-venous catheter-related infection Comparison of the roll-plate and sonication technique in 1000 catheters. Abstracts Of The Interscience Conference On Antimicrobial Agents & Chemotherapy. 43: 398, 2003

Catheter systems having multilumen guide catheter and retractable working catheter positioned in at least one lumen thereof. Official Gazette of the United States Patent & Trademark Office Patents 1281(3), Apr 20, 2004

Improved method for the detection of catheter colonization and catheter-related bacteremia in newborns. Diagnostic Microbiology and Infectious Disease 87(4): 311-314, 2017

Comparison of the roll plate method to the sonication method to diagnose catheter colonization and bacteremia in patients with long-term tunnelled catheters: a randomized prospective study. Journal of Clinical Microbiology 47(4): 885-888, 2009

Investigation of single lumen hemodialysis catheter for children and improvement of double lumen catheter. Artificial Organs 9(3): 297, 1985