Validation of the mapping accuracy of a novel non-invasive epicardial and endocardial electrophysiology system



Validation of the mapping accuracy of a novel non-invasive epicardial and endocardial electrophysiology system



Europace 17(8): 1282-1288



Use of a non-invasive electrocardiographic mapping system may aid in rapid diagnosis of atrial or ventricular arrhythmias or the detection of ventricular dyssynchrony. The aim of the present study was to validate the mapping accuracy of a novel non-invasive epi- and endocardial electrophysiology system (NEEES). Patients underwent pre-procedural computed tomography or magnetic resonance imaging of the heart and torso. Radiographic data were merged with the data obtained from the NEEES during pacing from implanted pacemaker leads or pacing from endocardial sites using an electroanatomical mapping system (CARTO 3, Biosense Webster). The earliest activation as denoted on the NEEES three-dimensional heart model was compared with the true anatomic location of the tip of the pacemaker lead or the annotated pacing site on the CARTO 3 map. Twenty-nine patients [mean age: 62 ± 11 years, 6/29 (11%) female, 21/29 (72%) with ischaemic cardiomyopathy] were enrolled into the pacemaker verification group. The mean distance from the non-invasively predicted pacing site to the anatomic reference site was 10.8 ± 5.4 mm for the right atrium, 7.7 ± 5.8 mm for the right ventricle, and 7.9 ± 5.7 mm for the left ventricle activated via the coronary sinus lead. Five patients [mean age 65 ± 4 years, 2 (33%) females] underwent CARTO 3 verification study. The mean distance between non-invasively reconstructed pacing site and the reference pacing site was 7.4 ± 2.7 mm for the right atrium, 6.9 ± 2.3 mm for the left atrium, 6.5 ± 2.1 mm for the right ventricle, and 6.4 ± 2.2 for the left ventricle, respectively. The novel NEEES was able to correctly identify the site of pacing from various endo- and epicardial sites with high accuracy.

(PDF emailed within 0-6 h: $19.90)

Accession: 059230111

Download citation: RISBibTeXText

PMID: 25643987

DOI: 10.1093/europace/euu339



Related references

Combined ventricular endocardial and epicardial substrate mapping using a sonomicrometry-based electroanatomical mapping system. Pacing and Clinical Electrophysiology 30(6): 781-786, 2007

Simultaneous Non-Invasive Epicardial and Endocardial Mapping in Patients With Brugada Syndrome: New Insights Into Arrhythmia Mechanisms. Journal of the American Heart Association 5(11): -, 2016

Simultaneous optical mapping system of endocardial and epicardial excitation. Conference Proceedings 2014: 2853-2856, 2015

Accuracy of combined endocardial and epicardial electroanatomic mapping of a reperfused porcine infarct model: a comparison of electrofield and magnetic systems with histopathologic correlation. Heart Rhythm 8(3): 439-447, 2011

Endocardial and epicardial ablation guided by nonsurgical transthoracic epicardial mapping to treat recurrent ventricular tachycardia. Journal Of Cardiovascular Electrophysiology. 9(3): 229-239, Ch, 1998

Mapping of epicardial activation in a rabbit model of chronic myocardial infarction: Response to atrial, endocardial, and epicardial pacing. Journal of Cardiovascular Electrophysiology 18(8): 862-868, 2007

Epicardial sock mapping following monophasic and biphasic shocks of equal voltage with and endocardial lead system. Journal of Cardiovascular Electrophysiology 7(4): 322-334, 1996

Electrophysiology of Myocardial Cells in the Epicardial, Midmyocardial, and Endocardial Layers of the Ventricle. Journal of Cardiovascular Pharmacology and Therapeutics 2(1): 61-72, 1997

Heterogeneity within the ventricular wall. Electrophysiology and pharmacology of epicardial, endocardial, and M cells. Circulation Research 69(6): 1427-1449, 1991

Accuracy of reproduction of human endocardial electrograms by a novel non-contact mapping system. Circulation 96(8 SUPPL ): I385, 10/21/97, 1997

Body surface mapping including relationships with endocardial and epicardial mapping. Annals of the New York Academy of Sciences 601: 148-179, 1990

Preliminary accuracy of reproduction of human endocardial electrograms using a novel non-contact mapping system. European Heart Journal 18(ABSTR SUPPL ): 206, 1997

Comparative accuracy of the vectorcardiogram and electrocardiogram in the localization of the accessory pathway in patients with Wolff-Parkinson-White syndrome: validation of a new vectorcardiographic algorithm by intraoperative epicardial mapping and electrophysiologic studies. American Heart Journal 119(3 Pt 1): 592-598, 1990

Computer techniques for epicardial and endocardial mapping. Progress in Cardiovascular Diseases 26(1): 15-32, 1983