Whole-body CT with high heat-capacity X-ray tube and automated tube current modulation--effect of tube current limitation on contrast enhancement, image quality and radiation dose



Whole-body CT with high heat-capacity X-ray tube and automated tube current modulation--effect of tube current limitation on contrast enhancement, image quality and radiation dose



European Journal of Radiology 84(5): 877-883



To evaluate the effect of tube current limitation on contrast enhancement, image quality, and radiation dose in whole-body 64-detector CT with a high heat-capacity X-ray tube and automated tube current modulation. One hundred eighteen patients were randomized into three whole-body CT protocols: tube current limitation at 210 mA, 450 mA, and no limitation. Signal-to-noise ratio (SNR), dose-length product (DLP), estimated effective dose (ED), and image quality were assessed. Mean SNR of aorta was comparable among protocols, but that of liver was somewhat lower in 210-mA than in 450-mA and no-limitation protocols (p<0.05). Mean DLP with 210-mA (533.8 mGy cm) was reduced by 31% from that with 450-mA (768.4 mGy cm) and by 38% from that with no-limitation protocol (861.3 mGy cm), respectively. Image quality was slightly degraded (p<0.017) with 210 mA relative to the others in thorax and pelvis, but no difference was found in diagnostic acceptability. For whole-body CT using multidetector CT mounted with a high heat-capacity X-ray tube, an appropriate tube current limitation setting may help reduce excessive radiation dose without significant compromise in diagnostic acceptability.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 059269857

Download citation: RISBibTeXText

PMID: 25740700

DOI: 10.1016/j.ejrad.2015.01.019


Related references

Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography. Ajnr. American Journal of Neuroradiology 30(9): 1754-1759, 2009

Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis. Acta Radiologica 52(10): 1101-1106, 2011

Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study. Academic Radiology 16(8): 997, 2009

Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol. Journal of Cardiovascular Computed Tomography 6(3): 184-190, 2012

Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality. Investigative Radiology 54(5): 265-272, 2019

Achieving consistent image quality and overall radiation dose reduction for coronary CT angiography with body mass index-dependent tube voltage and tube current selection. Clinical Radiology 69(9): 945-951, 2014

Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique--preliminary results. Radiology 256(2): 450-459, 2010

Adenosine-stress dynamic myocardial perfusion imaging using 128-slice dual-source CT in patients with normal body mass indices: effect of tube voltage, tube current, and iodine concentration on image quality and radiation dose. International Journal of Cardiovascular Imaging 30(Suppl. 2): 95, 2014

Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience. Radiology 254(1): 145-153, 2010

Optimizing radiation exposure in screening of body packing: image quality and diagnostic acceptability of an 80 kVp protocol with automated tube current modulation. Forensic Science Medicine and Pathology 13(2): 145-150, 2017

CT angiography of the aorta using 80 kVp in combination with sinogram-affirmed iterative reconstruction and automated tube current modulation: Effects on image quality and radiation dose. Journal of Medical Imaging and Radiation Oncology 60(2): 187-193, 2016

Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT. European Journal of Radiology Open 3: 182-190, 2016

Automatic tube current modulation for whole-body polytrauma CT with immobilization devices: is there an increase in radiation dose and degradation of image quality?. Emergency Radiology 24(1): 31-37, 2017

Radiation dose reduction to the breast in thoracic CT: comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current. Medical Physics 38(11): 6084-6092, 2011

Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation. International Journal of Cardiovascular Imaging 29(Suppl. 1): 47-51, 2013