X-ray and optical stereo-based 3D sensor fusion system for image-guided neurosurgery



X-ray and optical stereo-based 3D sensor fusion system for image-guided neurosurgery



International Journal of Computer Assisted Radiology and Surgery 11(4): 529-541



In neurosurgery, an image-guided operation is performed to confirm that the surgical instruments reach the exact lesion position. Among the multiple imaging modalities, an X-ray fluoroscope mounted on C- or O-arm is widely used for monitoring the position of surgical instruments and the target position of the patient. However, frequently used fluoroscopy can result in relatively high radiation doses, particularly for complex interventional procedures. The proposed system can reduce radiation exposure and provide the accurate three-dimensional (3D) position information of surgical instruments and the target position. X-ray and optical stereo vision systems have been proposed for the C- or O-arm. Two subsystems have same optical axis and are calibrated simultaneously. This provides easy augmentation of the camera image and the X-ray image. Further, the 3D measurement of both systems can be defined in a common coordinate space. The proposed dual stereoscopic imaging system is designed and implemented for mounting on an O-arm. The calibration error of the 3D coordinates of the optical stereo and X-ray stereo is within 0.1 mm in terms of the mean and the standard deviation. Further, image augmentation with the camera image and the X-ray image using an artificial skull phantom is achieved. As the developed dual stereoscopic imaging system provides 3D coordinates of the point of interest in both optical images and fluoroscopic images, it can be used by surgeons to confirm the position of surgical instruments in a 3D space with minimum radiation exposure and to verify whether the instruments reach the surgical target observed in fluoroscopic images.

(PDF emailed within 0-6 h: $19.90)

Accession: 059279013

Download citation: RISBibTeXText

PMID: 26410838

DOI: 10.1007/s11548-015-1290-2



Related references

A novel registration method for image-guided neurosurgery system based on stereo vision. Bio-Medical Materials and Engineering 26 Suppl 1: S967-S973, 2016

Accuracy analysis for image-guided neurosurgery using fiducial skin markers, 3D CT imaging, and an optical localizer system. Lemke, H U [Author], Vannier, M W [Author], Inamura, K [Author], Farman, A G [Author] International Congress Series; CAR '96: Computer assisted radiology 770-775, 1996

A low-cost PCI-bus-based ultrasound system for use in image-guided neurosurgery. Computerized Medical Imaging & Graphics 23(5): 267-276, 1999

A low-cost PCI-bus-based ultrasound system for use in image-guided neurosurgery. Computerized Medical Imaging and Graphics 23(5): 267-276, 2000

Multi-modality image fusion for image-guided neurosurgery. Lemke, H U, Vannier, M W, Inamura, K, Farman, A G International Congress Series; Computer assisted radiology and surgery 681-685, 1999

Interactive image-guided surgery in pediatric neurosurgery using an infrared-based system. Stereotactic & Functional Neurosurgery 66(1-3): 154-155, 1996

Image-guided neurosurgery system integrating AR-based navigation and open-MRI monitoring. Computer Aided Surgery 10(2): 59-71, 2005

Recognition by robot visual sensor based on sensor fusion - fuse range image and 2-dimensional image. Journal of Society of High Technology in Agriculture 9(2): 132-138, 1997

Mutual-information-based image to patient re-registration using intraoperative ultrasound in image-guided neurosurgery. Medical Physics 35(10): 4612-4624, 2008

A novel augmented reality system of image projection for image-guided neurosurgery. Acta Neurochirurgica 155(5): 943-947, 2013

Comparison of relative accuracy between a mechanical and an optical position tracker for image-guided neurosurgery. Journal of Image Guided Surgery 1(1): 30-34, 1995

Accurate calibration of a stereo-vision system in image-guided radiotherapy. Medical Physics 33(11): 4379-4383, 2006

Multi-focus image fusion using a guided-filter-based difference image. Applied Optics 55(9): 2230-2239, 2016

Assessment of an image-guided neurosurgery system using a head phantom. British Journal of Neurosurgery 30(6): 606-610, 2016

Augmented Inline-Based Navigation For Stereotactic Image Guided Neurosurgery. Proceedings. IEEE International Symposium on Biomedical Imaging: 1869-1872, 2011