+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

An observational cross-sectional study on the corneal endothelium of medium-term rigid gas permeable contact lens wearers



An observational cross-sectional study on the corneal endothelium of medium-term rigid gas permeable contact lens wearers



Contact Lens and Anterior Eye 40(2): 109-115



To assess if polymegethism and pleomorphism were evident in corneal endothelium after medium-term rigid gas permeable (RGP) contact lens wear. In a cross-sectional observational study over 12 years, single images of the central region of the corneal endothelium of one eye of 46 subjects were taken with a non-contact specular microscope, along with a measure of central corneal thickness (CCT). The images were printed onto A3-sized paper and 100 cells/image measured by planimetry. Subjects aged between 20 and 32 years, with an average cumulative RGP wear of 6.0+/- 1.6 years (range 3-9 years) were assessed; 26 of the subjects were Caucasian and 20 were Asian. The mean CCT was 0.515+/- 0.027mm. The group cell area value was 401+/- 42 sq micron to give an estimated endothelial cell density (ECD) of 2520+/- 273 cells/sq mm. As compared to a historical database, most endothelia (37/46) showed some changes with the mean coefficient of variation on cell area (COV) being 36.7+/- 8.0% and the percentage of 6-sided (HEX) being 51.8+/- 8.8%. There were modest correlations between years of RGP wear and both COV (p=0.009, r spearman=0.424) and HEX (p=0.025, r spearman=-0.291), but not for ECD or CCT. Corneal endothelial polymegethism appears to be a commonplace consequence of RGP lens wear with the magnitude of the change being related to the cumulative duration of the lens wear.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 059369581

Download citation: RISBibTeXText

PMID: 27986387

DOI: 10.1016/j.clae.2016.12.001


Related references

Corneal curvature changes in soft and rigid gas permeable contact lens wearers after two years of lens wear. Clao Journal 22(3): 186-188, 1996

Corneal topographic changes after refitting polymethylmethacrylate contact lens wearers into rigid gas permeable materials. Clao Journal 21(1): 47-51, 1995

Morphologic and fluorophotometric analysis of the corneal endothelium in long term hard and soft contact lens wearers. CLAO Journal 14(2): 105-109, 1988

A morphologic and fluorophotometric analysis of the corneal endothelium in long-term extended wear soft contact lens wearers. Clao Journal 15(2): 121-123, 1989

Change in corneal microstructure with rigid gas permeable contact lens use following collagen cross-linking: an in vivo confocal microscopy study. British Journal of Ophthalmology 98(4): 442-447, 2014

Acanthamoeba Keratitis among Rigid Gas Permeable Contact Lens Wearers in the United States, 2005 through 2011. Ophthalmology 123(7): 1435-1441, 2017

Corneal endothelial changes in contact lens wearers 2. analysis of factors affecting the corneal endothelium. Rinsho Ganka 43(1): 59-63, 1989

Changes in the corneal endothelium of contact lens wearers. Folia Ophthalmologica Japonica 39(7): 1309, 1988

Variations in corneal curvature and refractive error in CAB gas-permeable contact lens wearers. Journal of the American Optometric Association 55(3): 217-219, 1984

Effects of long-term rigid contact lens wear on the endothelium of corneal transplants for keratoconus 10 years after penetrating keratoplasty. Clao Journal 21(4): 265-267, 1995

Rigid gas permeable contact lens and corneal topography. Ophthalmic and Physiological Optics 21(3): 236-242, 2001

Pseudomonas corneal ulcer after use of extended-wear rigid gas-permeable contact lens. Cornea 8(3): 225-226, 1989

Corneal aberration changes after rigid gas permeable contact lens wear in keratokonic patients. Journal of Current Ophthalmology 28(4): 194-198, 2016

Alteration of corneal asphericity in rigid gas permeable contact lens induced warpage. Clao Journal 20(1): 27-31, 1994

The role of computerized corneal topography in rigid gas permeable contact lens fitting. Clao Journal 24(4): 206-209, 1998