+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Comprehensive performance comparison of high-resolution array platforms for genome-wide Copy Number Variation (CNV) analysis in humans



Comprehensive performance comparison of high-resolution array platforms for genome-wide Copy Number Variation (CNV) analysis in humans



Bmc Genomics 18(1): 321



High-resolution microarray technology is routinely used in basic research and clinical practice to efficiently detect copy number variants (CNVs) across the entire human genome. A new generation of arrays combining high probe densities with optimized designs will comprise essential tools for genome analysis in the coming years. We systematically compared the genome-wide CNV detection power of all 17 available array designs from the Affymetrix, Agilent, and Illumina platforms by hybridizing the well-characterized genome of 1000 Genomes Project subject NA12878 to all arrays, and performing data analysis using both manufacturer-recommended and platform-independent software. We benchmarked the resulting CNV call sets from each array using a gold standard set of CNVs for this genome derived from 1000 Genomes Project whole genome sequencing data. The arrays tested comprise both SNP and aCGH platforms with varying designs and contain between ~0.5 to ~4.6 million probes. Across the arrays CNV detection varied widely in number of CNV calls (4-489), CNV size range (~40 bp to ~8 Mbp), and percentage of non-validated CNVs (0-86%). We discovered strikingly strong effects of specific array design principles on performance. For example, some SNP array designs with the largest numbers of probes and extensive exonic coverage produced a considerable number of CNV calls that could not be validated, compared to designs with probe numbers that are sometimes an order of magnitude smaller. This effect was only partially ameliorated using different analysis software and optimizing data analysis parameters. High-resolution microarrays will continue to be used as reliable, cost- and time-efficient tools for CNV analysis. However, different applications tolerate different limitations in CNV detection. Our study quantified how these arrays differ in total number and size range of detected CNVs as well as sensitivity, and determined how each array balances these attributes. This analysis will inform appropriate array selection for future CNV studies, and allow better assessment of the CNV-analytical power of both published and ongoing array-based genomics studies. Furthermore, our findings emphasize the importance of concurrent use of multiple analysis algorithms and independent experimental validation in array-based CNV detection studies.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 059537184

Download citation: RISBibTeXText

PMID: 28438122

DOI: 10.1186/s12864-017-3658-x


Related references

Genome-wide mapping of copy number variation in humans: comparative analysis of high resolution array platforms. Plos one 6(11): E27859, 2011

Application of high-resolution array platform for genome-wide copy number variation analysis in patients with nonsyndromic cleft lip and palate. Journal of Clinical Laboratory Analysis 2018:, 2018

Genome-wide high-resolution analysis of DNA copy number alterations in NF1-associated malignant peripheral nerve sheath tumors using 32K BAC array. Genes Chromosomes and Cancer 48(10): 897-907, 2009

Comparison of genome-wide array genomic hybridization platforms for the detection of copy number variants in idiopathic mental retardation. Bmc Medical Genomics 4: 25, 2011

Enhancing genome-wide copy number variation identification by high density array CGH using diverse resources of pig breeds. Plos one 9(1): E87571, 2014

Genome-wide detection of copy number variation in Chinese indigenous sheep using an ovine high-density 600 K SNP array. Scientific Reports 7: 912, 2017

Genome-wide identification of copy number variation using high-density single-nucleotide polymorphism array in Japanese Black cattle. Bmc Genetics 17: 26, 2016

High-resolution genome-wide copy-number analyses identify localized copy-number alterations in Ewing sarcoma. Diagnostic Molecular Pathology 22(2): 76-84, 2013

Genome-wide array-CGH analysis reveals YRF1 gene copy number variation that modulates genetic stability in distillery yeasts. Oncotarget 6(31): 30650-30663, 2015

High-resolution copy number arrays in cancer and the problem of normal genome copy number variation. Genes Chromosomes and Cancer 47(11): 933-938, 2008

Integrated analysis of copy number alteration and RNA expression profiles of cancer using a high-resolution whole-genome oligonucleotide array. Experimental and Molecular Medicine 41(7): 462-470, 2009

A genome-wide high-resolution array-CGH analysis of cutaneous melanoma and comparison of array-CGH to FISH in diagnostic evaluation. Journal of Molecular Diagnostics 15(5): 581-591, 2013

High-resolution genome-wide copy-number analysis suggests a monoclonal origin of multifocal prostate cancer. Genes Chromosomes and Cancer 51(6): 579-589, 2012

Genome-wide detection of copy number variations using high-density SNP genotyping platforms in Holsteins. Bmc Genomics 14: 131, 2013

High resolution array CGH analysis of DNA sequence copy number variation in amplicons mapping to 20q13 in breast cancer. Proceedings of the American Association for Cancer Research Annual Meeting 40: 93, 1999