+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Force-assisted ultrasound imaging system through dual force sensing and admittance robot control



Force-assisted ultrasound imaging system through dual force sensing and admittance robot control



International Journal of Computer Assisted Radiology and Surgery 12(6): 983-991



Ultrasound imaging has been a gold standard for clinical diagnoses due to its unique advantages compared to other imaging modalities including: low cost, noninvasiveness, and safeness to the human body. However, the ultrasound scanning process requires applying a large force over extended periods of time, often in uncomfortable postures in order to maintain the desired orientation. This physical requirement over sonographers' careers often leads to musculoskeletal pain and strain injuries. To address this problem, we propose a cooperatively controlled robotic ultrasound system to reduce the force sonographers apply. The proposed system consists of two key components: a six-axis robotic arm that holds and actuates the ultrasound probe, and a dual force sensor setup that enables cooperative control and adaptive force assistance. With the admittance force control, the robotic arm complies with the motion of the operator, while assisting with force during the scanning. We validated the system through a user study involving expert sonographers and lay people and demonstrated 32-73% reduction in human applied force and 8- 18% improvement in image stability. These results indicate that the system has the potential to not only reduce the burden on the sonographer, but also provide more stable ultrasound scanning.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 059748125

Download citation: RISBibTeXText

PMID: 28343302

DOI: 10.1007/s11548-017-1566-9


Related references

A Multi-Function Force Sensing Instrument for Variable Admittance Robot Control in Retinal Microsurgery. IEEE International Conference on Robotics and Automation 2014: 1411-1418, 2014

3-DOF Force-Sensing Micro-Forceps for Robot-Assisted Membrane Peeling: Intrinsic Actuation Force Modeling. Proceedings of the .. Ieee/Ras-Embs International Conference on Biomedical Robotics and Biomechatronics. Ieee/Ras-Embs International Conference on Biomedical Robotics and Biomechatronics 2016: 489-494, 2016

A robot-assisted surgical system using a force-image control method for pedicle screw insertion. Plos one 9(1): E86346, 2014

Force sensing micro-forceps for robot assisted retinal surgery. Conference Proceedings 2012: 1401-1404, 2012

Micro-force sensing in robot assisted membrane peeling for vitreoretinal surgery. Medical Image Computing and Computer-Assisted Intervention 13(Pt 3): 303-310, 2010

3-DOF Force-Sensing Motorized Micro-Forceps for Robot-Assisted Vitreoretinal Surgery. IEEE Sensors Journal 17(11): 3526-3541, 2017

Evaluation of a Force-Sensing Handheld Robot for Assisted Retinal Vein Cannulation. Conference Proceedings 2018: 1-5, 2018

Design of 3-DOF force sensing micro-forceps for robot assisted vitreoretinal surgery. Conference Proceedings 2013: 5686-5689, 2013

Evaluation of force data with a force/torque sensor during FESS. A step towards robot-assisted surgery. Hno 56(8): 789-794, 2008

Towards Robot-Assisted Vitreoretinal Surgery: Force-Sensing Micro-Forceps Integrated with a Handheld Micromanipulator. IEEE International Conference on Robotics and Automation 2014: 1399-1404, 2014

Robot-Assisted Eccentric Contraction Training of the Tibialis Anterior Muscle Based on Position and Force Sensing. Sensors 19(6):, 2019

Towards Robot-Assisted Retinal Vein Cannulation: A Motorized Force-Sensing Microneedle Integrated with a Handheld Micromanipulator †. Sensors 17(10):, 2017

Development of a control algorithm for the ultrasound scanning robot (NCCUSR) using ultrasound image and force feedback. International Journal of Medical Robotics + Computer Assisted Surgery 13(2):, 2017

Admittance Control for Robot Assisted Retinal Vein Micro-Cannulation under Human-Robot Collaborative Mode. Iccas .. 2017: 862-866, 2017

Force Sensing Using Kalman Filtering Techniques for Robot Compliant Motion Control. Journal of Intelligent & Robotic Systems 18(1): 1-16, 1997