+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Heart rate variability as a predictor of hypotension following spinal for elective caesarean section: a prospective observational study



Heart rate variability as a predictor of hypotension following spinal for elective caesarean section: a prospective observational study



Anaesthesia 72(5): 603-608



Post-spinal hypotension remains a common and clinically-important problem during caesarean section, and accurate pre-operative prediction of this complication might enhance clinical management. We conducted a prospective, single-centre, observational study of heart rate variability in 102 patients undergoing elective caesarean section in a South African regional hospital. We performed Holter recording for ≥ 5 min in the hour preceding spinal anaesthesia. The low-frequency/high-frequency ratio component of heart rate variability was compared, using a logistic regression model, with baseline heart rate and body mass index (BMI) as a predictor of hypotension (defined as systolic arterial pressure < 90 mmHg) occurring from the time of spinal insertion until 15 min after delivery of the baby. We also assessed clinically relevant cut-point estimations for low-frequency/high-frequency ratio. Low-frequency/high-frequency ratio predicted hypotension (p = 0.046; OR 1.478, 95%CI 1.008-1.014), with an optimal cut-point estimation of 2.0; this threshold predicted hypotension better than previously determined thresholds (p = 0.003; c-statistic 0.645). Baseline heart rate (p = 0.20; OR 1.022, 95%CI 0.988-1.057) and BMI (p = 0.60; OR 1.017, 95%CI 0.954-1.085) did not predict hypotension. Heart rate variability analysis is a potentially useful clinical tool for the prediction of hypotension. Future studies should consider a low-frequency/high-frequency ratio threshold of 2.0 for prospective validation.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 059790035

Download citation: RISBibTeXText

PMID: 28133720

DOI: 10.1111/anae.13813


Related references

Heart Rate Variability as a Predictor of Hypotension Following Spinal for Elective Caesarean Section. Obstetric Anesthesia Digest 38(1): 31-33, 2018

Heart rate, but not heart rate variability or pulse oximetry parameters of perfusion, predicts hypotension during spinal anesthesia for a cesarean section: a prospective observational study. European Journal of Anaesthesiology 31: 189-190, 2014

Effect of weight gain during pregnancy on heart rate variability and hypotension during caesarean section under spinal anaesthesia. Anaesthesia 66(12): 1106-1111, 2011

Effect of Weight Gain During Pregnancy on Heart Rate Variability and Hypotension During Caesarean Section Under Spinal Anaesthesia. Obstetric Anesthesia Digest 33(1): 62-63, 2013

Prediction of hypotension during spinal anesthesia for elective cesarean section by altered heart rate variability induced by postural change. International Journal of Obstetric Anesthesia 29: 34-38, 2017

The Effect of Rate of Injection on Hypotension during Spinal Anesthesia for Elective Caesarean Section. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2001): Abstract No A-1042, 2002

Can Point-of-Care Ultrasound Predict Spinal Hypotension During Caesarean Section? A Prospective Observational Study. Obstetric Anesthesia Digest 38(3): 114-115, 2018

Can point-of-care ultrasound predict spinal hypotension during caesarean section? A prospective observational study. Anaesthesia 73(1): 15-22, 2018

Crystalloid coloading vs. colloid coloading in elective Caesarean section: postspinal hypotension and vasopressor consumption, a prospective, observational clinical trial. Journal of Anesthesia 33(1): 40-49, 2019

Effect of Ondansetron on the Occurrence of Hypotension and on Neonatal Parameters during Spinal Anesthesia for Elective Caesarean Section: A Prospective, Randomized, Controlled, Double-Blind Study. Anesthesiology Research and Practice 2015: 158061, 2015

Heart rate variability changes during caesarean section under general or spinal anaesthesia. European Journal of Anaesthesiology 21(Suppl. 32): 157-158, 2004

Heart rate variability as a predictor of hypotension after spinal anesthesia in hypertensive patients. Korean Journal of Anesthesiology 65(4): 317-321, 2013

Heart rate variability predicts severe hypotension after spinal anesthesia for elective cesarean delivery. Anesthesiology 102(6): 1086-1093, 2005

Heart Rate Variability Predicts Severe Hypotension after Spinal Anesthesia for Elective Cesarean Delivery. Obstetric Anesthesia Digest 26(1): 15-16, 2006

Heart Rate Variability Predicts Severe Hypotension After Spinal Anesthesia for Elective Cesarean Delivery. Yearbook of Anesthesiology and Pain Management 2006: 192-193, 2006