+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Improved tomographic reconstruction of large-scale real-world data by filter optimization



Improved tomographic reconstruction of large-scale real-world data by filter optimization



Advanced Structural and Chemical Imaging 2(1): 17



In advanced tomographic experiments, large detector sizes and large numbers of acquired datasets can make it difficult to process the data in a reasonable time. At the same time, the acquired projections are often limited in some way, for example having a low number of projections or a low signal-to-noise ratio. Direct analytical reconstruction methods are able to produce reconstructions in very little time, even for large-scale data, but the quality of these reconstructions can be insufficient for further analysis in cases with limited data. Iterative reconstruction methods typically produce more accurate reconstructions, but take significantly more time to compute, which limits their usefulness in practice. In this paper, we present the application of the SIRT-FBP method to large-scale real-world tomographic data. The SIRT-FBP method is able to accurately approximate the simultaneous iterative reconstruction technique (SIRT) method by the computationally efficient filtered backprojection (FBP) method, using precomputed experiment-specific filters. We specifically focus on the many implementation details that are important for application on large-scale real-world data, and give solutions to common problems that occur with experimental data. We show that SIRT-FBP filters can be computed in reasonable time, even for large problem sizes, and that precomputed filters can be reused for future experiments. Reconstruction results are given for three different experiments, and are compared with results of popular existing methods. The results show that the SIRT-FBP method is able to accurately approximate iterative reconstructions of experimental data. Furthermore, they show that, in practice, the SIRT-FBP method can produce more accurate reconstructions than standard direct analytical reconstructions with popular filters, without increasing the required computation time.

(PDF emailed within 0-6 h: $19.90)

Accession: 059843568

Download citation: RISBibTeXText

PMID: 28003954

DOI: 10.1186/s40679-016-0033-y


Related references

Characterizing Regularization Techniques for Spatial Filter Optimization in Oscillatory EEG Regression Problems : Guidelines Derived from Simulation and Real-World Data. Neuroinformatics 2018, 2018

Preparing Laboratory and Real-World EEG Data for Large-Scale Analysis: A Containerized Approach. Frontiers in Neuroinformatics 10: 7, 2016

The FARSEEING real-world fall repository: a large-scale collaborative database to collect and share sensor signals from real-world falls. European Review of Aging and Physical Activity 13: 8, 2016

Evaluating large-scale propensity score performance through real-world and synthetic data experiments. International Journal of Epidemiology 47(6): 2005-2014, 2018

Optimization of a novel biophysical model using large scale in vivo antisense hybridization data displays improved prediction capabilities of structurally accessible RNA regions. Nucleic Acids Research 45(9): 5523-5538, 2017

Reconstruction of real tomographic data using algebraic methods. Conference Proceedings 2008: 2717-2720, 2009

Trace: a high-throughput tomographic reconstruction engine for large-scale datasets. Advanced Structural and Chemical Imaging 3(1): 6, 2017

Real-Space x-ray tomographic reconstruction of randomly oriented objects with sparse data frames. Optics Express 22(3): 2403-2413, 2014

Assessing Real-World Data Quality: The Application of Patient Registry Quality Criteria to Real-World Data and Real-World Evidence. Therapeutic Innovation and Regulatory Science 2019: 2168479019837520, 2019

D.E. diatomaceous earth filtration optimization and large scale filter systems start-up Brewing. 1983

Improved accuracy of echocardiographic endocardial borders by spatiotemporal filtered Fourier reconstruction: description of the method and optimization of filter cutoffs. Circulation 77(2): 415-428, 1988

Pain relief and improved physical function in knee osteoarthritis patients receiving ongoing hylan G-F 20, a high-molecular-weight hyaluronan, versus other treatment options: data from a large real-world longitudinal cohort in Canada. Drug Design, Development and Therapy 9: 5633-5640, 2016

A large-scale taxonomy of real-world scenes. 2012

The analysis of large scale data taken from the world groundnut (Arachis hypogaea L.) germplasm collection. II. two-way data with mixed data types. Euphytica 105(2): 73-82, 1999

UCSF tomography: an integrated software suite for real-time electron microscopic tomographic data collection, alignment, and reconstruction. Journal of Structural Biology 157(1): 138-147, 2006