+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Intraoperative blood pressure changes during cemented versus uncemented bipolar hemiarthroplasty for displaced femoral neck fracture: a multi-center cohort study : The effect of bone cement for bipolar hemiarthroplasty in elderly patients



Intraoperative blood pressure changes during cemented versus uncemented bipolar hemiarthroplasty for displaced femoral neck fracture: a multi-center cohort study : The effect of bone cement for bipolar hemiarthroplasty in elderly patients



Archives of Orthopaedic and Trauma Surgery 137(4): 523-529



The purpose of this study was to compare the cemented bipolar hemiarthroplasty with uncemented about the change of intraoperative blood pressure and the incidence of major complications in elderly patients with femoral neck fracture. This multiple center prospective cohort study included only patients with acute displaced femoral neck fracture (Garden stage III or IV). All patients were treated with cemented or uncemented bipolar hemiarthroplasty using modified Hardinge or Watson-Jones approach in the lateral decubitus position. Baseline data, medical history, type of anesthesia, FiO2 value, the number of vasopressor using during operation, femoral component, intraoperative blood pressure, SaO2, and major complications were evaluated. Of 164 patients (45 males and 119 females), 86 underwent cemented and 78 underwent uncemented bipolar hemiarthroplasty. Baseline medical histories were similar in both groups. In both the cemented and uncemented groups, intraoperative systolic blood pressure significantly decreased during cementing or rasping (106.3 and 103.6 mmHg) and after femoral component insertion (103.3 and 99.1 mmHg) compared to before rasping (120.7 and 116.4 mmHg) (p < 0.0001, respectively). Donaldson's grade seemed more favorable in uncemented group than in cemented group during cementing or rasping, during stem insertion; however, no patients experienced the lethal complication in both groups. Intraoperative blood pressure did not change during cemented and uncemented bipolar hemiarthrplasty for displaced femoral neck fracture. If the standard modern cement technique was performed during operation, bone cement is a safe and acceptable for elderly patients who have a lot of medical histories.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 059879948

Download citation: RISBibTeXText

PMID: 28213848

DOI: 10.1007/s00402-017-2651-9


Related references

Bateman bipolar hemiarthroplasty for displaced intracapsular femoral neck fractures. Uncemented versus cemented. Clinical Orthopaedics and Related Research 1994(302): 75-82, 1994

Unipolar versus bipolar uncemented hemiarthroplasty for elderly patients with displaced intracapsular femoral neck fractures. Journal of Orthopaedic Surgery 19(1): 8, 2011

Unipolar versus bipolar uncemented hemiarthroplasty for elderly patients with displaced intracapsular femoral neck fractures. Journal of Orthopaedic Surgery 19(2): 260; Author Reply 260, 2011

Unipolar hemiarthroplasty versus bipolar hemiarthroplasty in the most elderly patients with displaced femoral neck fractures: a randomised, controlled trial. International Orthopaedics 35(11): 1703-1711, 2011

Unipolar hemiarthroplasty versus bipolar hemiarthroplasty in patients with displaced femoral neck fractures: a four-year follow-up of a randomised controlled trial. International Orthopaedics 37(12): 2457-2464, 2013

Is cemented bipolar hemiarthroplasty a safe treatment for femoral neck fracture in elderly patients?. Clinical Interventions in Aging 10: 1063-1067, 2015

Unipolar Versus Bipolar Hemiarthroplasty for Displaced Femoral Neck Fractures in Elderly Patients. Orthopedics 38(11): 697-702, 2015

Cemented versus uncemented hemiarthroplasty in patients with displaced femoral neck fractures. Pakistan Journal of Medical Sciences 32(1): 44-48, 2016

Uni- and bipolar hemiarthroplasty with a modern cemented femoral component provides elderly patients with displaced femoral neck fractures with equal functional outcome and survivorship at medium-term follow-up. Archives of Orthopaedic and Trauma Surgery 134(9): 1251-1259, 2014

Bipolar hemiarthroplasty for subcapital fracture of the femoral neck. A prospective randomised trial of cemented Thompson and uncemented Moore stems. The Journal of Bone and Joint Surgery. British volume 73-B(2): 322-324, 1991

Bipolar hemiarthroplasty for subcapital fracture of the femoral neck a prospective randomized trial of cemented thompson and uncemented moore stems. Journal of Bone & Joint Surgery British Volume 73(2): 322-324, 1991

Comparative Study of Surgical Management of Fracture Neck of Femur with Cemented Versus Uncemented Bipolar Hemiarthroplasty. Journal of Clinical and Diagnostic Research 11(2): Rc17-Rc21, 2017

Intraoperative periprosthetic femur fracture during bipolar hemiarthroplasty for displaced femoral neck fractures. Archives of Orthopaedic and Trauma Surgery 138(9): 1189-1198, 2018

Lower reoperation rate for cemented hemiarthroplasty than for uncemented hemiarthroplasty and internal fixation following femoral neck fracture: 12- to 19-year follow-up of patients aged 75 years or more. Acta Orthopaedica 84(3): 254-259, 2013

Systematic review of cemented versus uncemented hemiarthroplasty for displaced femoral neck fractures in older patients. Archives of Orthopaedic and Trauma Surgery 132(4): 455-463, 2012