Solutions to decrease a systematic error related to AAPH addition in the fluorescence-based ORAC assay



Solutions to decrease a systematic error related to AAPH addition in the fluorescence-based ORAC assay



Analytical Biochemistry 519: 27-29



Oxygen radical absorbance capacity (ORAC) assay in 96-well multi-detection plate readers is a rapid method to determine total antioxidant capacity (TAC) in biological samples. A disadvantage of this method is that the antioxidant inhibition reaction does not start in all of the 96 wells at the same time due to technical limitations when dispensing the free radical-generating azo initiator 2,2'-azobis (2-methyl-propanimidamide) dihydrochloride (AAPH). The time delay between wells yields a systematic error that causes statistically significant differences in TAC determination of antioxidant solutions depending on their plate position. We propose two alternative solutions to avoid this AAPH-dependent error in ORAC assays.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 060263650

Download citation: RISBibTeXText

PMID: 27965064

DOI: 10.1016/j.ab.2016.12.009


Related references

Characteristics of the spin-trapping reaction of a free radical derived from AAPH: further development of the ORAC-ESR assay. Analytical and Bioanalytical Chemistry 403(7): 1961-1970, 2012

Systematic error arising from 'sequential' standard addition calibrations. 2. Determination of analyte mass fraction in blank solutions. Analytica Chimica Acta 648(2): 153-156, 2009

Analytical parameters of the microplate-based ORAC-pyrogallol red assay. Journal of Aoac International 94(5): 1562-1566, 2011

Analytical Parameters of the Microplate-Based Orac-Pyrogallol Red Assay. Journal of Aoac International 94(5): 1562-1566, 2011

High-throughput assay of oxygen radical absorbance capacity (ORAC) using a multichannel liquid handling system coupled with a microplate fluorescence reader in 96-well format. Journal of Agricultural and Food Chemistry 50(16): 4437-4444, 2002

Percept-based and object-based error processing: an experimental dissociation of error-related negativity and error positivity. Clinical Neurophysiology 122(2): 299-310, 2011

Discovery of acetyl-coenzyme A carboxylase 2 inhibitors: comparison of a fluorescence intensity-based phosphate assay and a fluorescence polarization-based ADP Assay for high-throughput screening. Assay and Drug Development Technologies 5(2): 225-235, 2007

Application of a Microplate-Based Orac-Pyrogallol Red Assay for the Estimation of Antioxidant Capacity: First Action 2012.03. Journal of Aoac International 95(6): 1558-1561, 2012

Role of alkoxyl radicals on the fluorescein-based ORAC (Oxygen Radical Absorbance Capacity) assay. Free Radical Biology and Medicine 75(Suppl. 1): S38, 2014

Application of a microplate-based ORAC-pyrogallol red assay for the estimation ofantioxidant capacity: First Action 2012.03. Journal of Aoac International 95(6): 1558-1561, 2012

Microplate-based Oxygen Radical Absorbance Capacity (ORAC) assay of hydrophilic and lipophilic compartments in plasma. Nutritional Sciences 9(1): 48-54, 2006

Systematic error in fluorescence correlation measurements identified by a simple saturation model of fluorescence. Analytical Chemistry 76(7): 1963-1970, 2004

A fluorescence quenching-based sensor using new metallo-tetraazaporphyrin dye as a recognition element for aniline assay in aqueous solutions. Analytica Chimica Acta 646(1-2): 97-103, 2009

Directed evolution of an esterase from Pseudomonas fluorescens. Random mutagenesis by error-prone PCR or a mutator strain and identification of mutants showing enhanced enantioselectivity by a resorufin-based fluorescence assay. Biological Chemistry 380(7-8): 1029-1033, 1999

Antioxidant capacity of phenolic compounds in acidic medium: A pyrogallol red-based ORAC (oxygen radical absorbance capacity) assay. Journal of Food Composition and Analysis 32(2): 116-125, 2013