Tolerance levels of CT number to electron density table for photon beam in radiotherapy treatment planning system



Tolerance levels of CT number to electron density table for photon beam in radiotherapy treatment planning system



Journal of Applied Clinical Medical Physics 19(1): 271-275



The accuracy of computed tomography number to electron density (CT-ED) calibration is a key component for dose calculations in an inhomogeneous medium. In a previous work, it was shown that the tolerance levels of CT-ED calibration became stricter with an increase in tissue thickness and decrease in the effective energy of a photon beam. For the last decade, a low effective energy photon beam (e.g., flattening-filter-free (FFF)) has been used in clinical sites. However, its tolerance level has not been established yet. We established a relative electron density (ED) tolerance level for each tissue type with an FFF beam. The tolerance levels were calculated using the tissue maximum ratio (TMR) and each corresponding maximum tissue thickness. To determine the relative ED tolerance level, TMR data from a Varian accelerator and the adult reference computational phantom data in the International Commission on Radiological Protection publication 110 (ICRP-110 phantom) were used in this study. The 52 tissue components of the ICRP-110 phantom were classified by mass density as five tissues groups including lung, adipose/muscle, cartilage/spongy-bone, cortical bone, and tooth tissue. In addition, the relative ED tolerance level of each tissue group was calculated when the relative dose error to local dose reached 2%. The relative ED tolerances of a 6 MVFFF beam for lung, adipose/muscle, and cartilage/spongy-bone were ±0.044, ±0.022, and ±0.044, respectively. The thicknesses of the cortical bone and tooth groups were too small to define the tolerance levels. Because the tolerance levels of CT-ED calibration are stricter with a decrease in the effective energy of the photon beam, the tolerance levels are determined by the lowest effective energy in useable beams for radiotherapy treatment planning systems.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 060407319

Download citation: RISBibTeXText

PMID: 29152898

DOI: 10.1002/acm2.12226


Related references

Effect of computed tomography number-relative electron density conversion curve on the calculation of radiotherapy dose and evaluation of Monaco radiotherapy treatment planning system. Australasian Physical and Engineering Sciences in Medicine 2019, 2019

Tolerance levels for quality assurance of electron density values generated from CT in radiotherapy treatment planning. Physics in Medicine & Biology 47(9): 1485-1492, 2002

Intercomparison of radiotherapy treatment planning systems for external photon and electron beam dose calculations. Radiotherapy & Oncology. 29(3): 327-335, 1993

Three-dimensional photon treatment planning. Report of the Collaborative Working Group on the evaluation of treatment planning for external photon beam radiotherapy. International Journal of Radiation Oncology, Biology, Physics 21(1): 1-265, 1991

Effect of age-dependent bone electron density on the calculated dose distribution from kilovoltage and megavoltage photon and electron radiotherapy in paediatric MRI-only treatment planning. British Journal of Radiology 91(1081): 20170511, 2017

Evaluation of electron dose calculations accuracy of a treatment planning system in radiotherapy of breast cancer with photon-electron technique. Journal of Cancer Research and Therapeutics 14(Suppl.): S1110-S1116, 2018

Modulated photon radiotherapy (XMRT): an algorithm for the simultaneous optimization of photon beamlet energy and intensity in external beam radiotherapy (EBRT) planning. Physics in Medicine and Biology 61(4): 1476-1498, 2016

Imaging opportunities for treatment planning in intraoperative electron beam radiotherapy IOERT Developments in the context of RADIANCE system. Reports of Practical Oncology & Radiotherapy, 2013

Long-term stability of the Hounsfield unit to electron density calibration curve in cone-beam computed tomography images for adaptive radiotherapy treatment planning. Journal of RadioTherapy in Practice 14(04): 410-417, 2015

Estimation of electron density, effective atomic number and stopping power ratio using dual-layer computed tomography for radiotherapy treatment planning. Physica Medica 56: 34-40, 2018

Initial implementation of the conversion from the energy-subtracted CT number to electron density in tissue inhomogeneity corrections: an anthropomorphic phantom study of radiotherapy treatment planning. Medical Physics 42(3): 1378-1388, 2016

Accuracy checks of physical beam modifier factors algorithm used in computerized treatment planning system for a 15 MV photon beam. Reports of Practical Oncology & RadioTherapy 14(6): 214-220, 2009

Boosting runtime-performance of photon pencil beam algorithms for radiotherapy treatment planning. Physica Medica 28(4): 273-280, 2013

Comparison of pencil beam and collapsed cone algorithms, in radiotherapy treatment planning for 6 and 10 MV photon. Journal of Ayub Medical College, Abbottabad 22(3): 152-154, 2012

Tolerance levels of mass density for CT number calibration in photon radiation therapy. Journal of Applied Clinical Medical Physics 2019, 2019