+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

A Critical Comparison of Hanging Mercury Drop Electrode and Long Lasting Sessile Drop Mercury Electrode in A.C. Anodic Stripping Voltammerty



A Critical Comparison of Hanging Mercury Drop Electrode and Long Lasting Sessile Drop Mercury Electrode in A.C. Anodic Stripping Voltammerty



Analytical Letters 17(8): 623-650




Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 061750362

Download citation: RISBibTeXText

DOI: 10.1080/00032718408069091


Related references

Determination of trace metals by anodic-stripping voltammetry with a new kind of mercury electrode: The long-lasting sessile-drop electrode. Talanta 28(11): 839-842, 1981

Direct determination of trace and sub trace metals in natural waters by differential pulse anodic stripping voltammetry use of long lasting sessile drop mercury electrodes compared to commercial hanging drop mercury electrodes kemula type. Analytical Letters 15(19): 1565-1584, 1982

Characterization and utilization of a long-lasting sessile-drop mercury electrode in differential pulse anodic-stripping voltammetric subtrace metal analysis of natural waters. Talanta 29(9): 751-756, 1982

Anodic stripping of heavy metals using a hanging mercury drop electrode in a flow system. Electroanalysis. 10(10): 701-706,., 1998

Increased sensitivity of anodic stripping voltammetry at the hanging mercury drop electrode by ultracathodic deposition. Analytica Chimica Acta 701(2): 152-156, 2011

Low-level determination of silicon in steels by anodic stripping voltammetry on a hanging mercury drop electrode. Talanta 82(5): 1839-1844, 2010

Disturbance of a Film of Triton X-100 on the Hanging Mercury Drop Electrode during the Determination of Metal Ions by Anodic Stripping Voltammetry. Collection of Czechoslovak Chemical Communications 58(2): 291-294, 1993

Determination of Zn, Cd, Pb, Cu, Sb and Bi in milk by differential pulse anodic stripping voltammetry with a hanging mercury drop electrode following two independent mineralisation methods. Analusis 13(10): 471-473, 1985

Direct and simultaneous determinations of Zn, Cd, Pb, Cu, Sb and Bi dissolved in sea water by differential pulse anodic stripping voltammetry with a hanging mercury drop electrode. Analytica Chimica Acta 106(1): 23-37, 1979

Trace zinc determination in acid media by differential pulse anodic stripping voltammetry at a hanging drop mercury electrode. Analytical Chemistry 48(4): 759-761, 1976

Direct Determination of Trace and Sustrace Metals in Natural Waters by Dpasv. The Use of Long-Lasting Sessile-Drop Mercury Electrodes Compared to Commercial Hanging-Drop Mercury Electrodes (Kemula Type). Analytical Letters 15(19): 1565-1584, 1982

Studies of pretreatments in the determination of Zn, Cd, Pb, Cu, Sb and Bi in suspended particulate matter and plankton by differential-pulse anodic-stripping voltammetry with a hanging mercury drop electrode. Talanta 29(8): 651-654, 1982

Implementation of a differential pulse anodic stripping voltammetry (DPASV) at a hanging mercury drop electrode (HMDE) procedure for the analysis of airborne heavy metals. Analytical Letters 34(13): 2349-2360, 2001

Electrochemical behaviour of natural and biosynthetic polynucleotides at the mercury electrode Part IV. Reduction and adsorption of polyriboadenylic acid at the hanging mercury drop electrode. Bioelectrochemistry and Bioenergetics 2(3): 204-214, 1975

Adsorptive stripping voltammetric determination of albendazole at a hanging mercury drop electrode. Analytical Letters 32(15): 2965-2975, 1999