Silicone Breast Implant Rupture: Pitfalls of Magnetic Resonance Imaging and Relative Efficacies of Magnetic Resonance, Mammography, and Ultrasound



Silicone Breast Implant Rupture: Pitfalls of Magnetic Resonance Imaging and Relative Efficacies of Magnetic Resonance, Mammography, and Ultrasound



Plastic & Reconstructive Surgery 104(7): 2054-2062




Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 062831425

Download citation: RISBibTeXText

DOI: 10.1097/00006534-199912000-00016


Related references

Silicone breast implant rupture: pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound. Plastic and Reconstructive Surgery 104(7): 2054-2062, 1999

Comparison of mammography, sonography, and magnetic resonance imaging in the detection of silicone-gel breast implant rupture. Annals of Plastic Surgery 33(3): 247-55; Discussion 256-7, 1994

The Life Span of Silicone Gel Breast Implants and a Comparison of Mammography, Ultrasonography, and Magnetic Resonance Imaging in Detecting Implant Rupture. Annals of Plastic Surgery 41(6): 577-586, 1998

Appropriate use of magnetic resonance imaging and ultrasound to detect early silicone gel breast implant rupture in postmastectomy reconstruction. Plastic and Reconstructive Surgery 134(1): 13e-20e, 2014

The life span of silicone gel breast implants and a comparison of mammography, ultrasonography, and magnetic resonance imaging in detecting implant rupture: a meta-analysis. Annals of Plastic Surgery 41(6): 577-85; Discussion 585-6, 1998

Discussion: appropriate use of magnetic resonance imaging and ultrasound to detect early silicone gel breast implant rupture in postmastectomy reconstruction. Plastic and Reconstructive Surgery 134(1): 21e-23e, 2014

Efficacy of ultrasound, mammography and magnetic resonance imaging in detecting breast implant rupture: A retrospective study of 175 reconstructive and aesthetic sub-pectoral breast augmentation cases. Journal of Plastic Reconstructive and Aesthetic Surgery 70(11): 1520-1526, 2017

Comparative Silicone Breast Implant Evaluation Using Mammography, Sonography, and Magnetic Resonance Imaging. Plastic & Reconstructive Surgery 94(5): 620-627, 1994

Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants. Plastic and Reconstructive Surgery 94(5): 620-627, 1994

Imaging spectrum of breast implant complications: mammography, ultrasound, and magnetic resonance imaging. Seminars in Ultrasound Ct and Mr 21(5): 351-361, 2000

Evaluation of the rupture of silicone breast implants by mammography, ultrasonography and magnetic resonance imaging in asymptomatic patients: correlation with surgical findings. Sao Paulo Medical Journal 122(2): 41-47, 2004

Comparative Study of Breast Implant Rupture Using Mammography, Sonography, and Magnetic Resonance Imaging: Correlation with Surgical Findings. Yearbook of Plastic and Aesthetic Surgery 2010: 186-187, 2010

Comparative study of breast implant rupture using mammography, sonography, and magnetic resonance imaging: correlation with surgical findings. Breast Journal 14(6): 532-537, 2008

Application of Breast Ultrasound Elastography to Differentiate Intracapsular Collection from Silicone-Induced Granuloma of Breast Implant Capsule Complementarily to Contrast-Enhanced Breast Magnetic Resonance Imaging. Breast Cancer 11: 1178223417737994, 2017

The diagnosis of silicone breast-implant rupture: clinical findings compared with findings at magnetic resonance imaging. Annals of Plastic Surgery 54(6): 583-589, 2005