Evaluation of Modified Look-Locker Inversion Recovery and Arrhythmia-Insensitive Rapid Cardiac T1 Mapping Pulse Sequences in Cardiomyopathy Patients



Evaluation of Modified Look-Locker Inversion Recovery and Arrhythmia-Insensitive Rapid Cardiac T1 Mapping Pulse Sequences in Cardiomyopathy Patients



Journal of Computer Assisted Tomography 42(5): 732-738



The aim of this study was to compare the performance of arrhythmia-insensitive rapid (AIR) and modified Look-Locker inversion recovery (MOLLI) T1 mapping in patients with cardiomyopathies. In 58 patients referred for clinical cardiac magnetic resonance imaging at 1.5 T, we compared MOLLI and AIR native and postcontrast T1 measurements. Two readers independently analyzed myocardial and blood T1 values. Agreement between techniques, interreader agreement per technique, and intrascan agreement per technique were evaluated. The MOLLI and AIR T1 values were strongly correlated (r = 0.98); however, statistically significantly different T1 values were derived (bias 80 milliseconds, pooled data, P < 0.01). Both techniques demonstrated high repeatability (MOLLI, r = 1.00 and coefficient of repeatability [CR] = 72 milliseconds; AIR, r = 0.99 and CR = 184.2 milliseconds) and produced high interreader agreement (MOLLI, r = 1.00 and CR = 51.7 milliseconds; AIR, r = 0.99 and CR = 183.5 milliseconds). Arrhythmia-insensitive rapid and MOLLI sequences produced significantly different T1 values in a diverse patient cohort.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 063212703

Download citation: RISBibTeXText

PMID: 29613994

DOI: 10.1097/rct.0000000000000746


Related references

Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart. Journal of Magnetic Resonance Imaging 26(4): 1081-1086, 2007

Arrhythmia insensitive rapid cardiac T1 mapping pulse sequence. Journal of Cardiovascular Magnetic Resonance 15(1 Suppl.), 2013

Arrhythmia insensitive rapid cardiac T1 mapping pulse sequence. Magnetic Resonance in Medicine 70(5): 1274-1282, 2013

Wideband arrhythmia-Insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable-cardioverter-defibrillator. Magnetic Resonance in Medicine 74(2): 336-345, 2015

Inversion group (IG) fitting: A new T1 mapping method for modified look-locker inversion recovery (MOLLI) that allows arbitrary inversion groupings and rest periods (including no rest period). Magnetic Resonance in Medicine 75(6): 2332-2340, 2016

Improved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice. Plos one 12(11): E0187621, 2017

Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magnetic Resonance in Medicine 52(1): 141-146, 2004

Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. Journal of Cardiovascular Magnetic Resonance 12: 69, 2010

Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer. Magnetic Resonance Imaging 33(4): 363-373, 2015

Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners. Journal of Cardiovascular Magnetic Resonance 15: 64, 2013

Accuracy, precision, and reproducibility of myocardial T1 mapping: A comparison of four T1 estimation algorithms for modified look-locker inversion recovery (MOLLI). Magnetic Resonance in Medicine 78(5): 1746-1756, 2017

Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery. Magnetic Resonance in Medicine 67(3): 622-627, 2012

Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging. European Radiology 26(6): 1775-1782, 2016

Small animal Look-Locker inversion recovery (SALLI) for simultaneous generation of cardiac T1 maps and cine and inversion recovery-prepared images at high heart rates: initial experience. Radiology 261(1): 258-265, 2011

Real-time Triggered RAdial Single-Shot Inversion recovery for arrhythmia-insensitive myocardial T1 mapping: motion phantom validation and in vivo comparison. Magnetic Resonance in Medicine 81(3): 1714-1725, 2019