+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Experimental Robot Model Adjustments Based on Force-Torque Sensor Information



Experimental Robot Model Adjustments Based on Force-Torque Sensor Information



Sensors 18(3):



The computational complexity of humanoid robot balance control is reduced through the application of simplified kinematics and dynamics models. However, these simplifications lead to the introduction of errors that add to other inherent electro-mechanic inaccuracies and affect the robotic system. Linear control systems deal with these inaccuracies if they operate around a specific working point but are less precise if they do not. This work presents a model improvement based on the Linear Inverted Pendulum Model (LIPM) to be applied in a non-linear control system. The aim is to minimize the control error and reduce robot oscillations for multiple working points. The new model, named the Dynamic LIPM (DLIPM), is used to plan the robot behavior with respect to changes in the balance status denoted by the zero moment point (ZMP). Thanks to the use of information from force-torque sensors, an experimental procedure has been applied to characterize the inaccuracies and introduce them into the new model. The experiments consist of balance perturbations similar to those of push-recovery trials, in which step-shaped ZMP variations are produced. The results show that the responses of the robot with respect to balance perturbations are more precise and the mechanical oscillations are reduced without comprising robot dynamics.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 064060633

Download citation: RISBibTeXText

PMID: 29534477

DOI: 10.3390/s18030836


Related references

A force/torque sensor-based technique for robot harvesting of fruits and vegetables. IROS ' 90 Proceedings of the IEEE International Workshop on Intelligent Robots and Systems ' 90 Towards a new frontier of applications Ibaraki, Japan, 3-6 July 1990: 231-235, 1990

Evaluation of force data with a force/torque sensor during FESS. A step towards robot-assisted surgery. Hno 56(8): 789-794, 2008

Use of a Force-Torque Sensor for Self-Calibration of a 6-DOF Medical Robot. Sensors 16(6):, 2016

Contact force measurement of instruments for force-feedback on a surgical robot: acceleration force cancellations based on acceleration sensor readings. MedicalImageComputingandComputer-AssistedIntervention8(Pt2):97, 2005

Enhanced precision of ankle torque measure with an open-unit dynamometer mounted with a 3D force-torque sensor. European Journal of Applied Physiology 115(11): 2303-2310, 2015

Multi-Axis Force/Torque Sensor Based on Simply-Supported Beam and Optoelectronics. Sensors 16(11):, 2016

An implementation of sensor-based force feedback in a compact laparoscopic surgery robot. Asaio Journal 55(1): 83-85, 2009

A force-sensing surgical tool with a proximally located force/torque sensor. International Journal of Medical Robotics + Computer Assisted Surgery 13(1):, 2017

Robot Intelligent Grasp of Unknown Objects Based on Multi-Sensor Information. Sensors 19(7):, 2019

Multilevel Fuzzy Control Based on Force Information in Robot-Assisted Decompressive Laminectomy. Advances in Experimental Medicine and Biology 1093: 263-279, 2018

Control of fracture reduction robot using force/torque measurement. Conference Proceedings 2008: 3265-3268, 2008

Automatic sensor placement for model-based robot vision. IEEE Transactions on Systems Man and Cybernetics. Part B Cybernetics 34(1): 393-408, 2004

Development of Torque Sensor with High Sensitivity for Joint of Robot Manipulator Using 4-Bar Linkage Shape. Sensors 16(7):, 2016

Physically based simulation model for acoustic sensor robot navigation. IEEE Transactions on Pattern Analysis and Machine Intelligence 9(6): 766-778, 1987

Preliminary analysis of force-torque measurements for robot-assisted fracture surgery. Conference Proceedings 2015: 4902-4905, 2015