OP03.07: Magnetic resonance diffusion weighted imaging (DWI) : reproducibility of apparent diffusion coefficient measurements for the normal fetal brain
Boyer, A.C.; Goncalves, L.F.; Lee, W.; Shetty, A.; Krisko, A.; Yeo, L.; Romero, R.
Ultrasound in Obstetrics and Gynecology 38(S1): 64-64
2011
ISSN/ISBN: 0960-7692
DOI: 10.1002/uog.9287
Accession: 064101701
PDF emailed within 0-6 h: $19.90
Related References
Boyer, A.C.; Gonçalves, L.F.; Lee, W.; Shetty, A.; Holman, A.; Yeo, L.; Romero, R. 2013: Magnetic resonance diffusion-weighted imaging: reproducibility of regional apparent diffusion coefficients for the normal fetal brain Ultrasound in Obstetrics and Gynecology: the Official Journal of the International Society of Ultrasound in Obstetrics and Gynecology 41(2): 190-197Rahbar, H.; Kurland, B.F.; Olson, M.L.; Kitsch, A.E.; Scheel, J.R.; Chai, X.; Usoro, J.; Lehman, C.D.; Partridge, S.C. 2016: Diffusion-Weighted Breast Magnetic Resonance Imaging: A Semiautomated Voxel Selection Technique Improves Interreader Reproducibility of Apparent Diffusion Coefficient Measurements Journal of Computer Assisted Tomography 40(3): 428-435
Priola, A.M.; Priola, S.M.; Parlatano, D.; Gned, D.; Giraudo, M.T.; Giardino, R.; Ferrero, B.; Ardissone, F.; Veltri, A. 2017: Apparent diffusion coefficient measurements in diffusion-weighted magnetic resonance imaging of the anterior mediastinum: inter-observer reproducibility of five different methods of region-of-interest positioning European Radiology 27(4): 1386-1394
Corona-Villalobos, C.P.; Pan, L.; Halappa, V.G.; Bonekamp, S.; Lorenz, C.H.; Eng, J.; Kamel, I.R. 2013: Agreement and reproducibility of apparent diffusion coefficient measurements of dual-b-value and multi-b-value diffusion-weighted magnetic resonance imaging at 1.5 Tesla in phantom and in soft tissues of the abdomen Journal of Computer Assisted Tomography 37(1): 46-51
Chaumoitre, K.; Colavolpe, N.; Shojai, R.; Sarran, A.; D' Ercole, C.; Panuel, M. 2007: Diffusion-weighted magnetic resonance imaging with apparent diffusion coefficient (ADC) determination in normal and pathological fetal kidneys Ultrasound in Obstetrics and Gynecology: the Official Journal of the International Society of Ultrasound in Obstetrics and Gynecology 29(1): 22-31
Ding, X.; Xu, H.; Zhou, J.; Xu, J.; Mei, H.; Long, Q.; Wang, Y. 2019: Reproducibility of normalized apparent diffusion coefficient measurements on 3.0-T diffusion-weighted imaging of normal pancreas in a healthy population Medicine 98(14): E15104
O'Flynn, E.A.M.; Morgan, V.A.; Giles, S.L.; deSouza, N.M. 2012: Diffusion weighted imaging of the normal breast: reproducibility of apparent diffusion coefficient measurements and variation with menstrual cycle and menopausal status European Radiology 22(7): 1512-1518
Wang, Y.-X.; Yuan, M.-Z.; Wen, Z.-X. 2016: Application of apparent diffusion coefficient and exponent apparent diffusion coefficient values in magnetic resonance imaging diffusion-weighted imaging to differentiate benign and malignant ovarian epithelial tumors Journal of Cancer Research and Therapeutics 12(1): 401-405
Priola, A.M.; Veltri, A.; Priola, S.M. 2018: Perfusion bias in the apparent diffusion coefficient measurements of diffusion-weighted magnetic resonance imaging Tumori 104(4): 315
Usuda, K.; Iwai, S.; Yamagata, A.; Iijima, Y.; Motono, N.; Doai, M.; Matoba, M.; Hirata, K.; Uramoto, H. 2021: How to Discriminate Lung Cancer from Benign Pulmonary Nodules and Masses? Usefulness of Diffusion-Weighted Magnetic Resonance Imaging with Apparent Diffusion Coefficient and Inside/Wall Apparent Diffusion Coefficient Ratio Clinical Medicine Insights. Oncology 15: 11795549211014863
Koinuma, M.; Ohashi, I.; Hanafusa, K.; Shibuya, H. 2005: Apparent diffusion coefficient measurements with diffusion-weighted magnetic resonance imaging for evaluation of hepatic fibrosis Journal of Magnetic Resonance Imaging: Jmri 22(1): 80-85
Cipolla, V.; Guerrieri, D.; Bonito, G.; Celsa, S.; de Felice, C. 2018: Effects of contrast-enhancement on diffusion weighted imaging and apparent diffusion coefficient measurements in 3-T magnetic resonance imaging of breast lesions Acta Radiologica 59(8): 902-908
Tagliafico, A.; Rescinito, G.; Monetti, F.; Villa, A.; Chiesa, F.; Fisci, E.; Pace, D.; Calabrese, M. 2012: Diffusion tensor magnetic resonance imaging of the normal breast: reproducibility of DTI-derived fractional anisotropy and apparent diffusion coefficient at 3.0 T La Radiologia Medica 117(6): 992-1003
Fornasa, F.; Montemezzi, S. 2012: Diffusion-weighted magnetic resonance imaging of the normal endometrium: temporal and spatial variations of the apparent diffusion coefficient Acta Radiologica 53(5): 586-590
Fornasa, F.; Montemezzi, S. 2012: Diffusion-weighted magnetic resonance imaging of the normal endometrium: temporal and spatial variations of the apparent diffusion coefficient Acta Radiologica (1987) 53(5): 586-590
Wang, H.-Y.; Wang, J.; Tang, Y.-H.; Ye, H.-Y.; Ma, L. 2015: Coronal diffusion-weighted magnetic resonance imaging of the kidney: agreement with axial diffusion-weighted magnetic imaging in terms of apparent diffusion coefficient values Chinese Medical Journal 128(4): 499-503
Raisi-Nafchi, M.; Faeghi, F.; Zali, A.; Haghighatkhah, H.; Jalal-Shokouhi, J. 2016: Preoperative Grading of Astrocytic Supratentorial Brain Tumors with Diffusion-Weighted Magnetic Resonance Imaging and Apparent Diffusion Coefficient Iranian Journal of Radiology: a Quarterly Journal Published by the Iranian Radiological Society 13(3): E30426
Aydin, H.; Kizilgöz, V.; Tatar, I.G.ün.ş; Damar, C.ğr.; Ugan, A.R.; Paker, I.; Hekimoğlu, B. 2012: Detection of prostate cancer with magnetic resonance imaging: optimization of T1-weighted, T2-weighted, dynamic-enhanced T1-weighted, diffusion-weighted imaging apparent diffusion coefficient mapping sequences and MR spectroscopy, correlated with biopsy and histopathological findings Journal of Computer Assisted Tomography 36(1): 30-45
Galons, J.P.; Trouard, T.; Gmitro, A.F.; Lien, Y.H. 1996: Hemodialysis increases apparent diffusion coefficient of brain water in nephrectomized rats measured by isotropic diffusion-weighted magnetic resonance imaging Journal of Clinical Investigation 98(3): 750-755
Braithwaite, A.C.; Dale, B.M.; Boll, D.T.; Merkle, E.M. 2009: Short- and midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen Radiology 250(2): 459-465