Characterization of Ge-doped optical fibres for MV radiotherapy dosimetry
Noor, N M.; Hussein, M.; Kadni, T.; Bradley, D.A.; Nisbet, A.
Radiation Physics and Chemistry 98: 33-41
2014
ISSN/ISBN: 0969-806X DOI: 10.1016/j.radphyschem.2013.12.017
Accession: 064449300
PDF emailed within 0-6 h: $19.90
Related References
Rahman, A.M.; Begum, M.; Zubair, H.; Abdul-Rashid, H.; Yusoff, Z.; Ung, N.; Bradley, D. 2017: Ge-doped silica optical fibres as RL/OSL dosimeters for radioTherapy dosimetry Sensors and Actuators A: Physical 264: 30-39Mat Nawi, S.N.; Abdul Sani, S.F.; Khandaker, M.U.; Ung, N.M.; Almugren, K.S.; Alkallas, F.H.; Bradley, D.A. 2020: Tailored Ge-doped fibres for passive electron radiotherapy dosimetry Plos one 15(7): E0235053
Veronese, I.; Chiodini, N.; Cialdi, S.; d'Ippolito, E.; Fasoli, M.; Gallo, S.; La Torre, S.; Mones, E.; Vedda, A.; Loi, G. 2017: Real-time dosimetry with Yb-doped silica optical fibres Physics in Medicine and Biology 62(10): 4218-4236
Noor, N. Mohd; Fadzil, M.S. Ahmad; Ung, N.M.; Maah, M.J.; Mahdiraji, G.A.; Abdul-Rashid, H.A.; Bradley, D.A. 2016: Radiotherapy dosimetry and the thermoluminescence characteristics of Ge-doped fibres of differing germanium dopant concentration and outer diameter Radiation Physics and Chemistry 126: 56-61
Abdul Rahman, A Taufek; Abu Bakar, N Khairunnisa; Chandra Paul, M; Bradley, D.A. 2014: Ultraviolet radiation (UVR) dosimetry system and the use of Ge-doped silica optical fibres Radiation Physics and Chemistry 104: 129-133
Issa, F; Hugtenburg, R P.; Nisbet, A; Bradley, D A. 2013: Novel high resolution 125I brachytherapy source dosimetry using Ge-doped optical fibres Radiation Physics and Chemistry 92: 48-53
Abdul Rahman, A.T.; Hugtenburg, R.P.; Abdul Sani, S.F.; Alalawi, A.I.M.; Issa, F.; Thomas, R.; Barry, M.A.; Nisbet, A.; Bradley, D.A. 2012: An investigation of the thermoluminescence of Ge-doped SiO2 optical fibres for application in interface radiation dosimetry Applied Radiation and Isotopes: Including Data Instrumentation and Methods for use in Agriculture Industry and Medicine 70(7): 1436-1441
Jafari, S.M.; Alalawi, A.I.; Hussein, M.; Alsaleh, W.; Najem, M.A.; Hugtenburg, R.P.; Bradley, D.A.; Spyrou, N.M.; Clark, C.H.; Nisbet, A. 2014: Glass beads and Ge-doped optical fibres as thermoluminescence dosimeters for small field photon dosimetry Physics in Medicine and Biology 59(22): 6875-6889
Mones, E.; Veronese, I.; Moretti, F.; Fasoli, M.; Loi, G.; Negri, E.; Brambilla, M.; Chiodini, N.; Brambilla, G.; Vedda, A. 2006: Feasibility study for the use of Ce3+-doped optical fibres in radioTherapy Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 562(1): 449-455
Faustov, A.V.; Gusarov, A.; Wuilpart, M.; Fotiadi, A.A.; Liokumovich, L.B.; Zolotovskiy, I.O.; Tomashuk, A.L.; de Schoutheete, T.; Megret, P. 2013: Comparison of Gamma-Radiation Induced Attenuation in Al-Doped, P-Doped and Ge-Doped Fibres for Dosimetry IEEE Transactions on Nuclear Science 60(4): 2511-2517
Parola, I.; Illarramendi, M.A.; Arrue, J.; Ayesta, I.; Jiménez, F.; Zubia, J.; Tagaya, A.; Koike, Y. 2016: Characterization of the optical gain in doped polymer optical fibres Journal of Luminescence 177: 1-8
Wesolowska, P.E.; Cole, A.; Santos, T.; Bokulic, T.; Kazantsev, P.; Izewska, J. 2017: Characterization of three solid state dosimetry systems for use in high energy photon dosimetry audits in radioTherapy Radiation Measurements 106: 556-562
Veng, T.; Palsdottir, B. 2005: Investigation and optimisation of fusion splicing abilities between erbium-doped optical fibres and standard singlemode fibres Electronics Letters 41(1): 10-11
Rais, N.N.M.; Bradley, D.A.; Hashim, A.; Osman, N.D.; Noor, N.M. 2019: Fabricated germanium-doped fibres for computed tomography dosimetry Applied Radiation and Isotopes: Including Data Instrumentation and Methods for use in Agriculture Industry and Medicine 153: 108810
Begum, M.; Rahman, A.M.; Begum, M.; Abdul-Rashid, H.; Yusoff, Z.; Bradley, D. 2018: Harnessing the thermoluminescence of Ge-doped silica flat-fibres for medical dosimetry Sensors and Actuators A: Physical 270: 170-176
Hashim, S.; Saripan, M.I.; Rahman, A.T.A.; Yaakob, N.H.; Bradley, D.A.; Alzimami, K. 2013: Effective Atomic Number of Ge-Doped and Al-Doped Optical Fibers for Radiation Dosimetry Purposes IEEE Transactions on Nuclear Science 60(2): 555-559
Abdul Rahman, A.; Bradley, D.; Doran, S.; Thierry, B.; Bräuer-Krisch, E.; Bravin, A. 2010: The thermoluminescence response of Ge-doped silica fibres for synchrotron microbeam radiation Therapy dosimetry Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 619(1-3): 167-170
Regnier, E.; Flammer, I.; Girard, S.; Gooijer, F.; Achten, F.; Kuyt, G. 2007: Low-Dose Radiation-Induced Attenuation at Infra Red Wavelengths for P-Doped, Ge-Doped and Pure Silica-Core Optical Fibres IEEE Transactions on Nuclear Science 54(4): 1115-1119
Fernandez Fernandez, A.; Okeeffe, S.; Fitzpatrick, C.; Brichard, B.; Berghmans, F.; Lewis, E. 2005: Gamma dosimetry using commercial PMMA optical fibres for nuclear environments Proc. Spie Int. Soc. Opt. Eng 5855: 499-502
Matejec, V.; Kasik, I.; Pospisilova, M. 1995: Preparation and optical properties of silica optical fibres with an Al2O3-doped core J. Non-Cryst. Solids 192-93: 195-198