Meta-analysis of the incidence of lead dislodgement with conventional and leadless pacemaker systems



Meta-analysis of the incidence of lead dislodgement with conventional and leadless pacemaker systems



Pacing and Clinical Electrophysiology 41(10): 1365-1371



Leadless cardiac pacemaker (LCP) implantation using a transcatheter was recently developed to avoid pocket- and lead-related complications. Although a LCP has an active fixation mechanism using tines or a helix, LCP and lead dislodgement issues remain a major safety concern for patients. This article reviews the literature to determine the incidence of lead and LCP dislodgement. A total of 18 studies which included 17,321 patients undergoing conventional single- or dual-chamber pacemaker implantation and three studies which included 2,116 patients undergoing LCP device implantation were reviewed. The incidence of lead dislodgement ranged from 1% to 2.69% in individual studies with a mean of 1.63%, weighted mean of 1.71%, and median of 1.60 %. There was a relatively higher lead dislodgement rate between atrial and ventricular electrodes (odds ratio [OR], 3.56; 95% confidence interval [CI], 1.9-6.70; P  =  0.6; I2   =  0%), and between magnetic resonance imaging conditional and conventional leads (OR, 2.79; 95% CI, 1.30-5.99; P  =  0.16; I2   =  46%). The use of active fixation leads (OR, 1.06; 95% CI, 0.66-1.70; P  =  0.29; I2   =  20%) showed no significant difference in dislodgement risk compared to passive fixation leads. The incidence of LCP device dislodgement was 0%, 0.13%, and 1% in three leadless pacemaker studies. The incidence rates of conventional pacemaker lead dislodgement vary in individual studies with an overall high incidence. Use of the currently available LCP systems appears to result in a lower rate of device dislodgement. This may reflect the effectiveness of this novel technology and the fixation design of LCP devices.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 065310772

Download citation: RISBibTeXText

PMID: 30066363

DOI: 10.1111/pace.13458


Related references

Incidence of Cardiac Perforation With Conventional and With Leadless Pacemaker Systems: A Systematic Review and Meta-Analysis. Journal of Cardiovascular Electrophysiology 28(3): 336-346, 2017

Leadless pacemaker implantation after explantation of infected conventional pacemaker systems: A viable solution?. Heart Rhythm 16(1): 66-71, 2019

Retraction Statement: Safety and feasibility of leadless pacemaker compared with traditional transvenous single-lead pacemaker: an animal study. Pacing and Clinical Electrophysiology 38(4): 536-536, 2015

Atrial lead dislodgement with a DDD pacemaker. Pacing and Clinical Electrophysiology 9(3): 436-440, 1986

Inadvertent pacemaker lead dislodgement. Pacing and Clinical Electrophysiology 41(9): 1266-1267, 2018

The small-tined pacemaker lead--absence of dislodgement. Pacing and Clinical Electrophysiology 3(2): 171-177, 1980

Leadless pacemaker versus transvenous single-chamber pacemaker therapy: A propensity score-matched analysis. Heart Rhythm 15(9): 1387-1393, 2018

Monocentric experience of leadless pacing with focus on challenging cases for conventional pacemaker. Acta Cardiologica 73(5): 459-468, 2018

Facioscapulohumeral muscular dystrophy and recurrent pacemaker lead dislodgement. American Heart Journal 122(4 Part 1): 1167-1169, 1991

Unusual mechanism of post-operative pacemaker lead dislodgement. Europace 16(9): 1355, 2014

Midterm Safety and Performance of a Leadless Cardiac Pacemaker: 3-Year Follow-up to the LEADLESS Trial (Nanostim Safety and Performance Trial for a Leadless Cardiac Pacemaker System). Circulation 137(6): 633-635, 2018

Pacemaker Lead Dislodgement Due to Left Shoulder Dislocation: A Case Report. Jbjs Case Connector 8(3): E63, 2018

Pacemaker atrial lead dislodgement and malposition inducing ventricular pacing. Boletin de la Asociacion Medica de Puerto Rico 83(3): 99-108, 1991

"Ratchet" syndrome, another etiology for pacemaker lead dislodgement: a case report. Heart Rhythm 4(6): 788-789, 2007

Hybrid cardiac resynchronization with leadless pacemaker and transvenous coronary sinus lead. Europace 20(9): 1505, 2018