EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Observational studies on macroprolactin in a routine clinical laboratory



Observational studies on macroprolactin in a routine clinical laboratory



Clinical Chemistry and Laboratory Medicine: -



It is now recommended that all samples with raised prolactin should be examined for the presence of macroprolactin. We performed a retrospective review of our experience of macroprolactin to determine the incidence and the natural history of macroprolactin. A retrospective study of macroprolactin was made in a large clinical laboratory. Macroprolactin was measured on those samples where it is requested and where the total prolactin is >1000 mIU/L. Prolactin was measured using the Siemens Centaur and macroprolactin was measured following polyethylene glycol (PEG)-precipitation. The incidence of macroprolactin in samples where the total prolactin was >1000 mIU/L was 36/670 (5.4%). During this period, 12,064 samples were received for prolactin analysis. Over the period since 2006, 22 subjects had a sample with an isolated macroprolactin measurement followed by another sample without macroprolactin after a median period of 0.46 years. Twenty-five subjects had multiple consecutive measurements of macroprolactin lasting a median period of 2.1 years. Fourteen subjects had more than six samples which had been subjected to PEG precipitation. In these subjects, the reproducibility of PEG precipitation over a median of 6 years was 1.1% CV (recovery 75% [26-110] (median [range])). The presence of macroprolactin can change over time and we cannot advise that once a test for macroprolactinemia has been performed that it is not necessary to repeat the investigation if a subsequent sample is hyperprolactinemic; nor can one assume that macroprolactin will not develop even if it has been excluded previously.

(PDF emailed within 0-6 h: $19.90)

Accession: 065365728

Download citation: RISBibTeXText

PMID: 29630507

DOI: 10.1515/cclm-2018-0074



Related references

Screening of patients with hyperprolactinemia for macroprolactin: experience in routine laboratory practice. Klinicheskaia Laboratornaia Diagnostika: 35-36, 2007

The impact on clinical practice of routine screening for macroprolactin. Journal of Clinical Endocrinology and Metabolism 90(7): 3927-3932, 2005

Vitamin K Antagonists Compared to Low-Molecular-Weight Heparins for Treatment of Cancer-Associated Venous Thromboembolism: An Observational Study in Routine Clinical Practice. An Observational Study in Routine Clinical Practice. Thrombosis and Haemostasis 117(11): 2163-2167, 2017

Optimisation of assessment for rheumatic diseases in clinical trials, observational studies and routine clinical care. Clinical and Experimental Rheumatology 32(5 Suppl 85): S-1, 2014

Laboratory and clinical aspects of the detection of macroprolactin using PEG precipitation. Journal of Endocrinology 160(SUPPL ): P144, March, 1999

Serum prolactin and macroprolactin in heart failure: no relation to established laboratory or clinical parameters. Annals of Clinical Biochemistry 48(Pt 1): 51-56, 2011

How to Interpret Data of Routine Laboratory Tests (Basic Laboratory Tests)--Various Methods to Interpret Routine Laboratory Data in 3 Clinical Laboratory Facilities--A Method at Shinshu University Hospital. Rinsho Byori. Japanese Journal of Clinical Pathology 63(9): 1064-1070, 2016

The EK 5-Aut measuring attachment to the Spekol (photometer) for enzyme studies in the clinical chemistry routine laboratory. Zeitschrift für Medizinische Labortechnik 10(5): 300-302, 1969

Taking a new biomarker into routine use--a perspective from the routine clinical biochemistry laboratory. Proteomics. Clinical Applications 4(12): 892-903, 2011

Impact of macroprolactin on galactorrhea and the rate of patients possibly affected by macroprolactin. Endocrine Journal 65(2): 203-211, 2017

Acute mechanical trauma to permanent teeth. General information, routine clinical examination, laboratory studies. Czasopismo Stomatologiczne 28(11): 1069-1072, 1975

Sensitivity to change of the health assessment questionnaire (HAQ) and other clinical and health status measures in rheumatoid arthritis: results of short-term clinical trials and observational studies versus long-term observational studies. Arthritis Care and Research 5(3): 130-136, 1992

Methods for using clinical laboratory test results as baseline confounders in multi-site observational database studies when missing data are expected. Pharmacoepidemiology and Drug Safety 25(7): 798-814, 2017

Carbohydrate malabsorption in clinical routine: a prospective observational study. Hepato-Gastroenterology 53(71): 673-677, 2006

Quantitative adjustment for macroprolactin is an integral part of laboratory assessment of hyperprolactinaemia. Experimental and Clinical Endocrinology & Diabetes 120(6): 376-380, 2012