Selecting noncoplanar beam directions in a patient coordinate system for radiotherapy planning



Selecting noncoplanar beam directions in a patient coordinate system for radiotherapy planning



Medical Dosimetry 2018



To introduce a beam angle selection method based on the patient coordinate system for treatment planning of noncoplanar intensity-modulated radiation therapy (IMRT). Traditionally, in radiotherapy planning, beam directions are selected in the machine coordinate system. A noncoplanar beam direction is established through a treatment table rotation followed by a gantry rotation. However, visualizing the beam direction relative to the patient is difficult. The suggestion here is to describe the beam direction in the patient coordinate system. First, a coplanar beam direction is selected in the transverse plane of the patient coordinate system. The noncoplanar beam direction is then obtained by adjusting the coplanar beam toward the foot or head in the patient coordinate system. Finally, the noncoplanar beam direction is expressed in terms of gantry and table angles in the machine coordinate system via formulae developed in this study. A 3D computer-aided design model of the linear accelerator (linac) is established with Solidworks and used to validate the feasibility of the proposed method. A clinical case was chosen to demonstrate the effectiveness of this method. Treatment plans with the conventional coplanar and noncoplanar beam settings were made. Compared with the conventional coplanar IMRT plan, improved normal tissue sparing of the organs at risk using the noncoplanar IMRT plan is evident. The proposed method for noncoplanar treatment planning makes beam direction selection simpler and straightforward.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 065912752

Download citation: RISBibTeXText

PMID: 30477750

DOI: 10.1016/j.meddos.2018.10.003


Related references

The automatic optimization arithmetic of selecting beam arcs in X-knife radiotherapy planning system. Zhongguo Yi Liao Qi Xie Za Zhi 26(1): 20-22, 2005

Beam angle selection for intensity-modulated radiotherapy (IMRT) treatment of unresectable pancreatic cancer: are noncoplanar beam angles necessary?. Clinical and Translational Oncology 15(9): 720-724, 2014

The tetrad and hexad Maximum beam separation as a starting point for noncoplanar 3-D treatment planning. International Journal of Radiation Oncology Biology Physics 27(SUPPL 1): 138, 1993

Noncoplanar Beam Angle Class Solutions to Replace Time-Consuming Patient-Specific Beam Angle Optimization in Robotic Prostate Stereotactic Body Radiation Therapy. International Journal of Radiation Oncology, Biology, Physics 92(4): 762-770, 2015

Effectiveness of noncoplanar IMRT planning using a parallelized multiresolution beam angle optimization method for paranasal sinus carcinoma. International Journal of Radiation Oncology, Biology, Physics 63(2): 594-601, 2005

CT beam pointer system for radiotherapy planning. Iyo Denshi to Seitai Kogaku. Japanese Journal of Medical Electronics and Biological Engineering 21(3): 166-173, 1983

The development of target-eye-view maps for selection of coplanar or noncoplanar beams in conformal radiotherapy treatment planning. Medical Physics 26(11): 2367-2372, 1999

The tetrad and hexad: Maximum beam separation as a starting point for noncoplanar 3D treatment planning: Prostate cancer as a test case. International Journal of Radiation Oncology Biology Physics 30(2): 439-446, 1994

Accelerated algorithm of dose calculation for treatment planning system of multi-source stereotactic radiotherapy system with gamma beam. Zhongguo Yi Liao Qi Xie Za Zhi 36(1): 15-18, 2013

Coordinate transformations for BEAM/EGSnrc Monte Carlo dose calculations of non-coplanar fields received from a DICOM-compliant treatment planning system. Physics in Medicine and Biology 51(23): N441-N449, 2006

Coordinate transformations for BEAM/EGSnrc Monte Carlo dose calculations of non- coplanar fields received from a DICOM-compliant treatment planning system. Physics in Medicine and Biology 52(13): 4007-4007, 2007

Treatment planning in the external beam radiotherapy of cancers of the genitourinary system. Frontiers of Radiation Therapy and Oncology 21: 195-220, 1987

Robust Planning for a Patient Treated in Decubitus Position with Proton Pencil Beam Scanning Radiotherapy. Cureus 9(9): E1706, 2017

Radiotherapy for gastric lymphoma: a planning study of 3D conformal radiotherapy, the half-beam method, and intensity-modulated radiotherapy. Journal of Radiation Research 55(6): 1141-1145, 2015

Two quality control procedures on radiotherapy beam calibration and treatment planning system implementation. Tumori 84(2): 150-154, 1998