+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Validation of SYBR green I based closed tube loop mediated isothermal amplification (LAMP) assay and simplified direct-blood-lysis (DBL)-LAMP assay for diagnosis of visceral leishmaniasis (VL)



Validation of SYBR green I based closed tube loop mediated isothermal amplification (LAMP) assay and simplified direct-blood-lysis (DBL)-LAMP assay for diagnosis of visceral leishmaniasis (VL)



Plos Neglected Tropical Diseases 12(11): E0006922



The World Health Organization has targeted elimination of visceral leishmaniasis (VL) in the Indian subcontinent (ISC) by 2020. Despite distinctive decline seen in the number of VL cases in ISC, there is still a quest for development of a diagnostic test which has the utility for detection of active infection and relapse cases and as a test of cure. The present study validated the sensitivity and specificity of SYBR Green I based closed tube LAMP assay reported by us for diagnosis of VL. The validation study was carried out at two endemic sites in India, located at Rajendra Memorial Research Institute of Medical Sciences (RMRIMS), Patna and Institute of Medical Sciences (IMS), Banaras Hindu University (BHU), Varanasi. Standard operating protocols were provided at the two sites for applying LAMP assay on confirmed VL cases. The diagnostic accuracy of LAMP assay was evaluated by Receiver operator curve (ROC) analysis. Furthermore, a simplified LAMP assay based on direct blood lysis, DBL-LAMP, was developed and verified for its diagnostic accuracy. A total of 267 eligible participants were included in the study which comprised of 179 VL cases and 88 controls. Sensitivity and specificity of the LAMP assay were 98.32% (95% C.I- 95.2-99.7%) and 96.59% (95% C.I.-90.4-99.3%), respectively. ROC curve analysis depicted no significant difference between area under curve (AUCROC) for LAMP assay and rK39 RDT, indicative of LAMP as an excellent diagnostic test. DBL-LAMP assay, performed on 67 VL and 100 control samples, yielded a sensitivity of 93.05% (95% C.I- 84.75-97%) and specificity of 100% (95% C.I.- 96.30-100%). The validated closed tube LAMP for diagnosis of VL will provide impetus to the ongoing VL elimination programme in ISC. The assay based on direct blood lysis promotes its scope for application in field settings by further reducing time and cost.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 065967793

Download citation: RISBibTeXText

PMID: 30439953

DOI: 10.1371/journal.pntd.0006922


Related references

Evaluation of SYBR green I based visual loop-mediated isothermal amplification (LAMP) assay for genus and species-specific diagnosis of malaria in P. vivax and P. falciparum endemic regions. Journal of Vector Borne Diseases 54(1): 54-60, 2017

Development and Assessment of Loop-Mediated Isothermal Amplification (LAMP) Assay for the Diagnosis of Human Visceral Leishmaniasis in Iran. Iranian Journal of Parasitology 9(1): 50-59, 2014

A rapid molecular diagnosis of cutaneous leishmaniasis by colorimetric malachite green-loop-mediated isothermal amplification (LAMP) combined with an FTA card as a direct sampling tool. Acta Tropica 153: 116-119, 2016

Sensitive and less invasive confirmatory diagnosis of visceral leishmaniasis in Sudan using loop-mediated isothermal amplification (LAMP). Plos Neglected Tropical Diseases 12(2): E0006264, 2018

Optimization of a Loop Mediated Isothermal Amplification (LAMP) Assay for In-Field Detection of Dichelobacter nodosus With aprV2 (VDN LAMP) in Victorian Sheep Flocks. Frontiers in Veterinary Science 6: 67, 2019

Rapid detection of β-lactamases directly from positive blood cultures using a loop-mediated isothermal amplification (LAMP)-based assay. International Journal of Antimicrobial Agents 46(3): 355-356, 2015

A loop-mediated isothermal amplification assay for the diagnosis of pulmonary tuberculosis. Letters in Applied Microbiology 68(3): 219-225, 2019

An integrated one-step assay combining thermal lysis and loop-mediated isothermal Dna amplification (Lamp) in 30 min from E. coli and M. smegmatis cells on a paper substrate. Sensors and Actuators B: Chemical 291: 74-80, 2019

Development and Validation of a Loop-Mediated Isothermal Amplification (LAMP) Assay for Detection of Citrus Leprosis Cytoplasmic Type 2 in Plants. Phytopathology 107(12): 52-53, 2017

Loop-mediated isothermal amplification (LAMP) assay for the diagnosis of fasciolosis in sheep and its application under field conditions. Parasites and Vectors 9: 73, 2016

Development of a loop-mediated isothermal amplification (LAMP) assay for rapid diagnosis of Babesia canis infections. Transboundary and Emerging Diseases 57(1-2): 63-65, 2010

Evaluation of loop mediated isothermal amplification (LAMP) assay in the diagnosis of tubercular lymphadenitis: A pilot study. Indian Journal of Tuberculosis 65(1): 76-79, 2018

Development of loop-mediated isothermal amplification (LAMP) assay for rapid diagnosis of ovine theileriosis in China. Parasitology Research 103(6): 1407-1412, 2008

Development and validation of a loop mediated isothermal amplification (LAMP) assay for the detection of Staphylococcus aureus in bovine mastitis milk samples. Molecular and Cellular Probes 30(5): 320-325, 2016

Rapid detection of Plasmodium vivax in saliva and blood using loop mediated isothermal amplification (LAMP) assay. Journal of Infection 67(3): 245-247, 2013